Plan Review Stops For Permit 20120440 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2021-01-12 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-01-12 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-01-12 |
Time |
16:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2020-12-09 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-12-09 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-12-09 |
Time |
17:07 |
Sent To |
|
|
Notes |
2020-12-09 17:08:51 | IS THIS ON THE GROUND FLOOR? PLEASE CONTACT | | [email protected] TO DISCUSS ADDRESSING. |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
P |
Date |
2021-01-07 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-01-07 |
Time |
10:01 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-01-07 |
Time |
10:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-02-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-02-17 |
Time |
17:16 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-02-17 |
Time |
14:48 |
Sent To |
|
|
Notes |
2021-02-17 17:18:48 | REDLINED - | | SHAFTS ARE PRESSURIZED | | DOOR (1403) TO COMPLY WITH FBC ACCESSIBILITY 404.2.4, | | MINIMUM 18" CLEARANCE REQUIRED PULL SIDE | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-01-07 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-01-07 |
Time |
10:54 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-01-07 |
Time |
09:02 |
Sent To |
|
|
Notes |
2021-01-07 10:53:57 | INTERIOR OFFICE BUILDOUT | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) DRAWINGS SHOW CORRIDOR WALLS BETWEEN ELEVATOR AND | | OFFICES AS NON FIRE RATED. PLEASE SHOW HOW THE EXISTING | | ELEVATOR HOISTWAY IS PROTECTED PER FBC 3006.3 | | 2) PLEASE SHOW THE REQUIRED MANEUVERING CLEARANCE AT | | DOOR (1403) FROM INSIDE THE CONFERENCE ROOM TO COMPLY | | WITH FBC ACCESSIBILITY 404.2.4 | | 3) PLEASE SHOW THE REQUIRED FLOOR SPACE FOR ALL | | ACCESSIBLE ELEMENTS SUCH AS SINK, MICROWAVE, | | REFRIGERATOR ETC. PER FBC 305 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2021-01-13 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-01-13 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-01-13 |
Time |
15:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2020-12-11 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-12-11 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-12-11 |
Time |
16:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-02-18 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-01-29 |
Time |
11:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-01-13 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-01-13 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2020-12-09 |
Time |
11:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2021-02-17 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-02-17 |
Time |
06:24 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-02-17 |
Time |
06:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-12-23 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-12-23 |
Time |
07:27 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-12-22 |
Time |
17:26 |
Sent To |
|
|
Notes |
2020-12-23 07:27:17 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT-20120440 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET ALS.1.1 INDICATES 2 CONFERENCE ROOMS, THE | | VENTILATION DESIGN ON SHEET M2.0.0 DOES NOT SHOW THESE | | ROOMS. PLEASE SHOW THE VENTILATION CALCULATIONS FOR | | THIS TENANT SPACE BASED ON USE OF SPACE AND TABLE | | 403.3.1.1. FBC M | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2021-02-18 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-02-18 |
Time |
16:48 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-02-18 |
Time |
16:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2021-01-06 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-01-06 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-01-06 |
Time |
11:24 |
Sent To |
|
|
Notes |
2021-01-06 13:51:54 | 1ST REVIEW FBC-2017 PLUMBING | | PERMIT- 20120440 | | 1/6/2021 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) P0.0.0: PLEASE PROVIDE PIPE MATERIAL SPECIFICATIONS | | FOR SANITARY DRAINS AND VENTS, WATER DISTRIBUTION AND | | SUPPLY LINES, CONDENSATE DISPOSAL- SECTION 303.2 FBC P. | | BASED ON MECHANICAL PLAN NOTES IT APPEARS PIPING MAY BE | | RUNNING THROUGH PLENUM RATED SPACES. | | | | 2) P0.0.0: IT APPEARS A PUMP WILL BE REQUIRED FOR THE | | NEW CONDENSATE PIPING. PLEASE SHOW THE LOCATION AND | | PROVIDE AN EQUIPMENT SCHEDULE ON THE PLAN- SECTION | | 314.2.1 FBC P. PLEASE NOTE CONDENSATE DRAINS SHALL BE | | TRAPPED AS REQUIRED BY THE EQUIPMENT OR APPLIANCE | | MANUFACTURER- 314.2.4. | | | | 3) P0.0.0 & P1.1.2: PLEASE INCLUDE THE BACKFLOW | | PREVENTERS IN THE FIXTURE SCHEDULE- TABLE 608.1 FBC P. | | | | 4) A1.1.1 & A3.0.1: SHOW THE CLEAR FLOOR SPACE DIAGRAM | | AND DIMENSIONS FOR THE NEW KITCHEN SINK- SECTION 606.2 | | FBC ACC. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-02-22 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-02-22 |
Time |
16:48 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-02-18 |
Time |
16:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-01-12 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-01-07 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-01-07 |
Time |
10:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2020-12-29 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2020-12-29 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2020-12-29 |
Time |
10:53 |
Sent To |
|
|
Notes |
|
|