Plan Review Details - Permit 20120318
Plan Review Stops For Permit 20120318
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-01-04 Cont ID  
Sent By cthroop Date 2021-01-04 Time 15:40 Rev Time 0.00
Received By cthroop Date 2021-01-04 Time 15:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-12-29 Cont ID  
Sent By cthroop Date 2020-12-29 Time 14:51 Rev Time 0.00
Received By cthroop Date 2020-12-29 Time 14:51 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2021-01-19 Cont ID  
Sent By abelisle Date 2021-01-19 Time 18:31 Rev Time 0.00
Received By abelisle Date 2021-01-19 Time 18:25 Sent To I
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-01-04 Cont ID  
Sent By abelisle Date 2021-01-04 Time 20:27 Rev Time 0.00
Received By abelisle Date 2021-01-04 Time 19:59 Sent To I
Notes
2021-01-04 20:27:421ST REVIEW FBC-2017 PLUMBING
 PERMIT-20120318
 1/4/2021
 CODES IN EFFECT:
  
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THERE ARE SECTIONS OF PRINTING ON THE GAS RISER
 DRAWING THAT ARE ILLEGIBLE. SUBMIT A CLEAR AND LEGIBLE
 SHEET THAT REFLECTS THE SCOPE OF WORK BEING DONE. WPB
 AMENDMENTS TO THE FBC SEC. 107.2.1. INFORMATION ON
 CONSTRUCTION DOCUMENTS.
 2) SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE
 LENGTH OF ALL CUT SECTIONS OF PIPE PER 2017 FBC FUEL
 GAS, SECS. 402.4.1, 402.4.2. OR 2017 FBC FUEL GAS RES
 SECS. G2413.4.1, G2413.4.2.
 3) TYPE OF GAS (LP OR NATURAL). WPB AMENDMENTS TO THE
 FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 4) SHOW THE LOCATION OF ALL MP (STEP-DOWN) REGULATORS.
 A LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY
 AHEAD OF EACH MP REGULATOR. 2017 FBC FUEL GAS SEC.
 409.4, FBC FUEL GAS RES. SEC. G2420.4.
 5) SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL
 PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE
 CORRUGATED STAINLESS STEEL TUBING (IF APPLICABLE) FOR
 EACH PIPE SIZE. WPB AMENDMENTS TO THE FBC SEC.107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS.
 6) SUBMIT COPY OF THE SIZING TABLES USED IN THE DESIGN
 FOR THE GAS SYSTEM OR PLACE A NOTE ON BOTH SETS OF
 PLANS LISTING THE SIZING TABLES FROM GAS CODES OR
 ANOTHER STANDARD THAT WERE USED IN THE DESIGN OF THIS
 SYSTEM 2017 FBC FUEL GAS SEC. 402.3 OR 2017 FBC FUEL
 GAS RES. SEC. G2413.3
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 ATELYO BELISLE
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 1:00 PM TO 4:00 PM
 [email protected]
 561-805-6695
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-01-20 Cont ID  
Sent By cthroop Date 2021-01-20 Time 11:08 Rev Time 0.00
Received By cthroop Date 2021-01-08 Time 18:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-01-05 Cont ID  
Sent By lmarchan Date 2021-01-05 Time 10:15 Rev Time 0.00
Received By lmarchan Date 2020-12-21 Time 15:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2021-01-19 Cont ID  
Sent By abelisle Date 2021-01-19 Time 18:25 Rev Time 0.00
Received By abelisle Date 2021-01-19 Time 18:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2021-01-04 Cont ID  
Sent By abelisle Date 2021-01-04 Time 19:59 Rev Time 0.00
Received By abelisle Date 2021-01-04 Time 19:59 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-01-20 Cont ID  
Sent By cthroop Date 2021-01-20 Time 11:07 Rev Time 0.00
Received By cthroop Date 2021-01-20 Time 11:07 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-01-04 Cont ID  
Sent By cthroop Date 2021-01-04 Time 15:41 Rev Time 0.00
Received By cthroop Date 2021-01-04 Time 15:41 Sent To  
Notes
2021-01-04 15:42:53VERIFIED DIGITAL SIG ON GENERATOR PAD AND CONTRACTORS
 SIG ON ELECTRIC AND GAS RISERS. CT

Review Stop Z ZONING
Rev No 1 Status P Date 2020-12-30 Cont ID  
Sent By awooten Date 2020-12-30 Time   Rev Time  
Received By awooten Date 2020-12-30 Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved