Plan Review Details - Permit 20110932
Plan Review Stops For Permit 20110932
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2021-01-14 Cont ID  
Sent By ccole Date 2021-01-14 Time 12:34 Rev Time 0.00
Received By ccole Date 2021-01-14 Time 12:11 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-12-08 Cont ID  
Sent By ccole Date 2020-12-08 Time 13:38 Rev Time 0.00
Received By ccole Date 2020-12-08 Time 13:38 Sent To  
Notes
2020-12-08 13:39:081ST REVIEW FBC-2017 RES. FUEL GAS
 PERMIT- 20110932
 12/8/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) GAS RISER:
  
 A) SHOW THE TOTAL LOAD OF THE SYSTEM- SECTION G2413.2
 FBC RES. PLEASE NOTE THE GENERATOR SPECS SUBMITTED
 UNDER THE MAIN GENERATOR PERMIT- 20120204 INDICATE A
 FULL GAS LOAD OF 306,000 BTUH FOR THE 24 KW GENERATOR.
  
 B) INDICATE THE TYPES OF PIPING AND THE PIPE SIZING
 TABLES USED- SEE SECTION G2413.3 AND TABLES G2413.4(1)-
 G2413.4(8) FBC RES.
  
 C) SHOW THE LOCATIONS OF THE STEP-DOWN REGULATORS AND
 THEIR OUTLET PRESSURES AT THE WATER HEATER AND
 GENERATOR- SECTION G2412.1 & G2421.2 FBC RES. PLEASE
 SUBMIT MARKED UP OR HIGHLIGHTED SPECS SHOWING THE
 SELECTED MODEL, THE MAX INLET AND OUTLET SIZE AND
 PRESSURES, SPRING DATA, AND ORIFICE SIZE.
  
 2) PLEASE NOTE THE GENERATOR SHALL BE INSTALLED A
 MINIMIUM OF 10 FT. FROM MECHANICAL AND GRAVITY AIR
 INTAKES INTO THE BUILDING- SECTION R303.5.1 FBC RES.
  
 3) THE CONTRACTOR OR QUALIFIER WHO PREPARED THE DRAWING
 SHALL PROVIDE HIS/HER PRINTED NAME AND SIGNATURE ON IT-
 SECTION 107.2.1 WPB, AND FLORIDA STATUTES 471.003(2)(H)
 & 471.025.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2021-01-14 Time   Rev Time 0.00
Received By lmarchan Date 2021-01-11 Time 11:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-12-08 Time   Rev Time 0.00
Received By aoliver Date 2020-12-02 Time 16:56 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-01-14 Cont ID  
Sent By ccole Date 2021-01-14 Time 12:35 Rev Time 0.00
Received By ccole Date 2021-01-14 Time 12:11 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2020-12-08 Cont ID  
Sent By ccole Date 2020-12-08 Time 13:40 Rev Time 0.00
Received By ccole Date 2020-12-08 Time 13:40 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-01-14 Cont ID  
Sent By ccole Date 2021-01-14 Time 12:35 Rev Time 0.00
Received By ccole Date 2021-01-14 Time 12:11 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-12-08 Cont ID  
Sent By ccole Date 2020-12-08 Time 13:41 Rev Time 0.00
Received By ccole Date 2020-12-08 Time 13:41 Sent To  
Notes
2020-12-08 13:42:511ST SIGNATURE REVIEW WPB.
 PERMIT- 20110932
 12/8/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE CONTRACTOR OR QUALIFIER WHO PREPARED THE DRAWING
 SHALL PROVIDE HIS/HER PRINTED NAME AND SIGNATURE ON IT-
 SECTION 107.2.1 WPB, AND FLORIDA STATUTES 471.003(2)(H)
 & 471.025.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved