Plan Review Stops For Permit 20110914 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2021-01-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-01-19 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-01-19 |
Time |
14:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-12-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-12-23 |
Time |
11:47 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-12-23 |
Time |
06:46 |
Sent To |
|
|
Notes |
2020-12-23 12:00:08 | PLAN REVIEW / BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2014 NEC | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. DESIGN AND INSTALLATION INSTRUCTIONS FOR ALUMINUM | | STORM PANELS SUBMITTED FOR REVIEW. | | NORTH ELEVATION INDICATES BI-FOLD WOOD SHUTTERS ARE TO | | BE INSTALLED. | | PLEASE CLARIFY | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | 2. SECTION VIEW AT BAR INDICATES A MOTORIZED AWNING | | WILL BE INSTALLED. NOTE STATES TO SEE LATERAL DETAIL. | | PROVIDE LATERAL DETAIL OF MOTORIZED AWNING. INCLUDE | | ATTACHMENT DETAIL. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | 3. PROVIDE LANDING AT EXTERIOR DOOR. | | R311.3 FLOORS AND LANDINGS AT EXTERIOR DOORS. | | | | THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH | | EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL NOT BE | | LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A | | MINIMUM DIMENSION OF 36 INCHES (914 MM) MEASURED IN THE | | DIRECTION OF TRAVEL. EXTERIOR LANDINGS SHALL BE | | PERMITTED TO HAVE A SLOPE NOT TO EXCEED 1/4 UNIT | | VERTICAL IN 12 UNITS HORIZONTAL (2-PERCENT). | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-11-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-28 |
Time |
13:11 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-28 |
Time |
12:47 |
Sent To |
|
|
Notes |
2020-11-28 13:13:40 | PLAN REVIEW / BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | NO PLANS SUBMITTED FOR REVIEW. | | | | 1. SUBMIT A FULL SET OF PLANS FOR PROPOSED SCOPE OF | | WORK. | | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2021-01-19 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-01-19 |
Time |
08:18 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-01-19 |
Time |
08:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-12-23 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-12-23 |
Time |
07:50 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-12-23 |
Time |
07:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-12-01 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-12-01 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-12-01 |
Time |
15:22 |
Sent To |
|
|
Notes |
2020-12-01 15:23:05 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | NO ELECTRICAL WORK SHOWN, PLEASE SHOW ALL ELECTRICAL | | WORK PROPOSED. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2021-01-19 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-01-19 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-01-19 |
Time |
16:17 |
Sent To |
|
|
Notes |
2021-01-19 16:21:49 | 01/19/21 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-12-22 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-12-22 |
Time |
11:13 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-12-22 |
Time |
11:13 |
Sent To |
|
|
Notes |
2020-12-22 11:12:22 | 12/22/20 1ST GAS REVIEW**DENIED** WITH COMMENTS | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | 1. CITY RECORDS SHOW AN EXISTING GAS SYSTEM AT THIS | | PROPERTY. THE BTU LOAD OF THE CURRENT GAS SYSTEM MUST | | BE ADDED TO THE TOTAL BTU LOAD ON THE SYSTEM TO ENSURE | | THE EXISTING SYSTEM IS SIZED CORRECTLY. IF UNDERSIZED, | | THE EXISTING SYSTEM MUST BE REDONE TO ENSURE A SAFE | | OPERATING SYSTEM. SUBMIT A GAS PIPING RISER DIAGRAM | | THAT SHOWS THE TYPE OF EXISTING APPLIANCE, THE BTU LOAD | | OF EACH APPLIANCE, THE PIPE SIZE AND TYPE OF PIPE TO | | EACH APPLIANCE, AND THE DISTANCE OF THE LONGEST LENGTH | | OF PIPING FROM THE POINT OF DELIVERY TO THE MOST REMOTE | | OUTLET AND THE LOAD OF THE SECTION. NOTE: IF THE | | EXISTING SYSTEM IS PRESSURE IS 2 PSI, A LINE PRESSURE | | REGULATOR IS REQUIRED AT ALL THE EXISTING APPLIANCES | | PER THE 2017 FBC R SECS. G2412.4, G2412.8, G2413.1, | | G2413.2, G2413.3. | | | | 2 INDICATE THE PLAN IN WHICH THE GAS CODE'S SIZING | | TABLES ARE BEING USED FOR THE SYSTEM PER THE WPB | | AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON | | CONSTRUCTION DOCUMENTS. | | | | 3. THE TYPE OF PIPE MENTION IS NOT APPROVED TO BE | | INSTALLED UNDERGROUND. YOU MAY USE TRAC PIPE OR PE FOR | | UNDERGROUND AND CSST OR METAL PIPE ABOVE GROUND, SO | | PLEASE CLARIFY PER THE WPB AMENDMENTS TO THE FBC SEC. | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | 4. GAS RISER DIAGRAM REQUIRED, SO PLEASE SUBMIT AN | | ISOMETRIC DRAWING THAT CLEARLY SHOWS THE LENGTH OF ALL | | CUT SECTIONS OF PIPE PER 2017 FBC RES. SECS. G2413.4.1, | | G2413.4.2. | | | | 5. SHOW THE TYPE OF PIPE MATERIAL BEING USED, ALL PIPE | | SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | CORRUGATED STAINLESS-STEEL OR TRAC PIPE TUBING (IF | | APPLICABLE) FOR EACH PIPE SIZE PER THE WPB AMENDMENTS | | TO THE FBC SEC.107.2.1 INFORMATION ON CONSTRUCTION | | DOCUMENTS. | | 6. A LICENSED CONTRACTOR MUST REQUIRE A SUB GAS PERMIT | | FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC | | SEC. 105.1. | | | | 7. TYPE OF GAS (LP OR NATURAL) PER THE WPB AMENDMENTS | | TO THE FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION | | DOCUMENTS. | | | | 8. SHOW ALL MP (STEP-DOWN) REGULATORS' LOCATION. A | | LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY | | AHEAD OF EACH MP REGULATOR. 2017 FBC RES. SEC. G2420.4. | | | | 9. SHOW THE DISTANCE FROM THE POINT OF DELIVERY (GAS | | METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND OR SYSTEM PER THE 2017 FBC | | RES. SEC. G2413.4.1. | | | | 10. IF THIS TANKLESS UNIT CALL FOR A 10.5" WATER COLUMN | | AND THE SERVICE METER DISCHARGES IS A 12" WATER COLUMN | | REQUIRING A REGULATOR FOR THIS UNIT AS PER | | MANUFACTURER'S SPECIFICATION. SUBMIT MANUFACTURER'S | | SPECIFICATIONS FOR THE PRESSURE REGULATORS. REGULATORS | | INSTALLED ON THE BUILDING'S EXTERIOR SHALL BE APPROVED | | FOR OUTDOOR INSTALLATION PER THE 2017 FBC RES. SEC. | | G2421.1. | | | | 10. INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | ON THE PLAN PER THE 2017 FBC RES. SEC. G2413.2. | | | | 11. SUBMIT MANUFACTURER'S SPECIFICATION | | SHEETS/INSTALLATION MANUAL FOR GAS TANK-LESS TO VERIFY | | COMPLIANCE WITH 2017 FBC RES. SEC. G2408.1. | | | | 12. PLEASE SHOW ALL REGULATORS, UNIONS IN FRONT OF | | REGULATOR 1' OF EITHER SIDE, DRIP LEG, LABEL SHUT OFF | | VALVES WITH THEM LABELED PER THE 2017 FBC RES. SEC | | G2421.2 | | | | 13. ON THE PLAN, PLEASE THE LOCATION OF THE TANK-LESS | | WATER HEATER AND THE LOCATION AND DISTANCE OF ANY | | OPERABLE DOORS OR WINDOWS IN RELATION TO THE WATER | | HEATER. THE LOCATION OF THE WATER HEATER SHALL COMPLY | | WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE | | HOUSE PLAN CAN BE HAND-DRAWN PER THE WPB AMENDMENTS TO | | THE FBC SEC. 107.2.1. INFORMATION ON CONSTRUCTION | | DOCUMENTS. | | | | NOTE: YOU MAY CHOOSE TO HAVE A GAS REVIEW DONE THIS | | TIME AND ADDRESS THE COMENTS ABOVE. THIS WILL HAVE THE | | GAS APPROVE FOR A SUB PERMIT, OR IF YOU DECIDED NOT TO | | ADDRESS THESE COMMENTS, PLEASE PUT A NOTE ON THE GAS | | HEATER ( A SEPARATE PERMIT BY A LICENSED CONTRACTOR FOR | | THE GAS SYSTEM). THEN PLEASE TAKE OFF ANY GAS SHOWN ON | | PLANS; THESE COMMENTS CAN BE FORWARD TO THE GAS | | CONTRACTOR FOR REFERENCE. AN N WILL BE PUT ON THIS | | REVIEW, WHICH STANDS FOR NOT REQUIRED BUT, A SUB PERMIT | | WON'T BE ISSUED UNIT A REVIEW IS DONE FOR THAT SUB | | PERMIT, SO PLEASE BE ADVISED ON THIS PROCEDURE. | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2021-01-21 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2021-01-21 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2021-01-21 |
Time |
12:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2020-12-28 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2020-12-28 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2020-12-28 |
Time |
13:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2020-12-03 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2020-12-03 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2020-12-03 |
Time |
12:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-01-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-01-21 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-01-15 |
Time |
16:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-12-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-12-29 |
Time |
18:11 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-12-10 |
Time |
18:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-12-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-12-09 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-11-23 |
Time |
09:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2021-01-27 |
|
|
Cont ID |
|
Sent By |
ccarvaja |
Date |
2021-01-27 |
Time |
08:28 |
Rev Time |
0.00 |
Received By |
ccarvaja |
Date |
2021-01-20 |
Time |
13:56 |
Sent To |
|
|
Notes |
2021-01-27 08:30:29 | 01/27/21 RECEIPT MU 2021 2879 - $546.52 - PAID. CC | 2021-01-20 13:57:12 | 01/20/21 EMAILED PALM BEACH COUNTY IMPACT FEE OFFICE. | | PERMIT READY TO BE REVIEWED, IF QUESTIONNAIRE UPLOADED. | | CC |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2020-12-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-12-28 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-12-28 |
Time |
11:51 |
Sent To |
|
|
Notes |
2020-12-28 11:52:32 | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | YOUR PROJECT OR EMAIL IT TO [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2021-01-19 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-01-19 |
Time |
06:01 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-01-19 |
Time |
06:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2020-12-22 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-12-22 |
Time |
06:42 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-12-22 |
Time |
06:42 |
Sent To |
|
|
Notes |
2020-12-22 06:43:34 | APPROVED WITH PRIVISO: ANCHORAGE OF CONDENSING UNIT | | MUST MEET FBC RES M1307.2 ME | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-11-24 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-11-24 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-11-24 |
Time |
08:46 |
Sent To |
|
|
Notes |
2020-11-24 08:54:43 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT-20110914 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE PROVIDE A CODE COMPLIANT MECHANICAL DRAWING | | SHOWING HOW THIS CHANGE OF USE WILL BE CONDITIONED. FBC | | 107.2 | | | | 2) PLEASE PROVIDE ENERGY CALCULATIONS FOR THIS SPACE. | | FBC EC 101.5.1.1.2 | | | | 3) PLEASE PROVIDE MECHANICAL EQUIPMENT SIZING | | CALCULATIONS. FBC EC R403.7.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2021-01-19 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-01-19 |
Time |
16:18 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-01-19 |
Time |
16:17 |
Sent To |
|
|
Notes |
2021-01-19 16:19:46 | 01/19/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2020-12-22 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-12-22 |
Time |
11:13 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-12-22 |
Time |
08:03 |
Sent To |
|
|
Notes |
2020-12-22 09:49:21 | 12/22/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | 1. THESE ARE MULTI-FAMILY DWELLINGS. THE WATER USERS | | WILL BE REQUIRED TO INSTALL A BACKFLOW PREVENTION | | ASSEMBLY AT THE POINT OF DELIVERY THAT IS LEAD-FREE AND | | A CURRENT YEAR CERTIFICATION PER THE CITY OF WEST PALM | | CROSS UTILITIES DEPARTMENT AND THEIR CONNECTION CONTROL | | PROGRAM. | | | | 2. A LICENSED CONTRACTOR MUST REQUIRE SUB PLUMBING AND | | GAS PERMITS FOR THE SCOPE OF WORK PER THE WPB | | AMENDMENTS TO THE FBC SEC. 105.1. | | | | 3. ON SHEET A-1; | | A. THE PLUMBING ISOMETRIC SHOW TWO AIR ADMITTANCE | | VALVE, THE SYSTEM MUST HAVE A VENT THROUGH THE ROOF. A | | MINIMUM OF ONE STACK VENT OR VENT STACK EXTENDED TO THE | | OUTDOORS TO THE OPEN AIR PER THE FBC SEC. P 918.7. SHOW | | COMPLIANCE WITH THE PLANS. | | | | B. PLEASE SHOW DIMENSION BETWEEN FIXTURES INSTALLATION | | TO CONFORM TO THE 2017 FBC SEC. R 2705.1 (5). | | | | C. HOT WATER LINES NOT IN CONDITION SPACE SHALL BE | | INSULATED WITH A MINIMUM R-3 PER THE 2017 FBC SEC. RE | | 403.5.3. | | | | D. HOT GAS HEATER IF CONDENSATE NEEDS TO BE 1' AWAY | | FROM STRUCTURE PER THE 2017 FBC SEC. R318.5. | | | | 4. PLEASE PROVIDE MANUFACTURES INSTALLATION INSTRUCTION | | FOR TH GAS WATER HEATER PER THE WPB AMENDMENTS TO THE | | FBC 107.2.1. | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-11-30 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-11-30 |
Time |
16:35 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-11-30 |
Time |
16:22 |
Sent To |
|
|
Notes |
2020-11-30 16:35:37 | 1ST REVIEW FBC-2017 RES. | | PERMIT- 20110914 | | 11/30/2020 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SUBMIT PLUMBING PLANS AND SPECIFICATIONS INCLUDING A | | SANITARY RISER DRAWING- SECTION 107.3.5.3 WPB. | | | | 2) PROVIDE A PLUMBING SUB-PERMIT APPLICATION- SECTION | | 105.1 WPB. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2021-01-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-01-19 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-01-19 |
Time |
14:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-12-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-12-23 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-12-23 |
Time |
11:07 |
Sent To |
|
|
Notes |
2020-12-23 11:23:04 | PLAN REVIEW / ROOFING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2014 NEC | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE ENHANCED UPLIFT PRESSURE REQUIREMENTS FOR | | PERIMETER AND CORNER AREAS PREPARED BY A DESIGN | | PROFESSIONAL PER NOTE #7, NOA 20-0131.01. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2021-01-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-01-19 |
Time |
15:33 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-01-19 |
Time |
14:30 |
Sent To |
|
|
Notes |
2021-01-19 15:34:40 | HARD COPY OF PLANS WITH SIG AND SEAL DROPPED OFF AT | | CITY HALL ON 1/19/2021 PER JO. CT |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2020-12-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-12-23 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-12-23 |
Time |
07:25 |
Sent To |
|
|
Notes |
2020-12-23 11:19:19 | PLAN REVIEW / SIGNATURES | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | SIGNATURE. | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | WET SEAL AND SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-11-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-28 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-28 |
Time |
12:47 |
Sent To |
|
|
Notes |
2020-11-28 13:15:18 | PLAN REVIEW / SIGNATURES | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. NO PLANS SUBMITTED FOR REVIEW. | | | | 2. NEW SIGNATURE REVIEW REQUIRED. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2021-01-21 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2021-01-21 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2021-01-21 |
Time |
12:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2020-12-28 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2020-12-28 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2020-12-28 |
Time |
13:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-12-03 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-12-03 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2020-12-03 |
Time |
12:40 |
Sent To |
|
|
Notes |
|
|