Plan Review Details - Permit 20110914
Plan Review Stops For Permit 20110914
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-01-19 Cont ID  
Sent By cthroop Date 2021-01-19 Time 15:55 Rev Time 0.00
Received By cthroop Date 2021-01-19 Time 14:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-12-23 Cont ID  
Sent By cthroop Date 2020-12-23 Time 11:47 Rev Time 0.00
Received By cthroop Date 2020-12-23 Time 06:46 Sent To  
Notes
2020-12-23 12:00:08PLAN REVIEW / BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2014 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. DESIGN AND INSTALLATION INSTRUCTIONS FOR ALUMINUM
 STORM PANELS SUBMITTED FOR REVIEW.
 NORTH ELEVATION INDICATES BI-FOLD WOOD SHUTTERS ARE TO
 BE INSTALLED.
 PLEASE CLARIFY
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2. SECTION VIEW AT BAR INDICATES A MOTORIZED AWNING
 WILL BE INSTALLED. NOTE STATES TO SEE LATERAL DETAIL.
 PROVIDE LATERAL DETAIL OF MOTORIZED AWNING. INCLUDE
 ATTACHMENT DETAIL.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 3. PROVIDE LANDING AT EXTERIOR DOOR.
 R311.3 FLOORS AND LANDINGS AT EXTERIOR DOORS.
  
 THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH
 EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL NOT BE
 LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A
 MINIMUM DIMENSION OF 36 INCHES (914 MM) MEASURED IN THE
 DIRECTION OF TRAVEL. EXTERIOR LANDINGS SHALL BE
 PERMITTED TO HAVE A SLOPE NOT TO EXCEED 1/4 UNIT
 VERTICAL IN 12 UNITS HORIZONTAL (2-PERCENT).
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-11-28 Cont ID  
Sent By cthroop Date 2020-11-28 Time 13:11 Rev Time 0.00
Received By cthroop Date 2020-11-28 Time 12:47 Sent To  
Notes
2020-11-28 13:13:40PLAN REVIEW / BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NO PLANS SUBMITTED FOR REVIEW.
  
 1. SUBMIT A FULL SET OF PLANS FOR PROPOSED SCOPE OF
 WORK.
  
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2021-01-19 Cont ID  
Sent By jleahy Date 2021-01-19 Time 08:18 Rev Time 0.00
Received By jleahy Date 2021-01-19 Time 08:00 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-12-23 Cont ID  
Sent By jleahy Date 2020-12-23 Time 07:50 Rev Time 0.00
Received By jleahy Date 2020-12-23 Time 07:45 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-12-01 Cont ID  
Sent By jleahy Date 2020-12-01 Time 15:22 Rev Time 0.00
Received By jleahy Date 2020-12-01 Time 15:22 Sent To  
Notes
2020-12-01 15:23:05ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 NO ELECTRICAL WORK SHOWN, PLEASE SHOW ALL ELECTRICAL
 WORK PROPOSED.

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2021-01-19 Cont ID  
Sent By lcrespo Date 2021-01-19 Time 16:17 Rev Time 0.00
Received By lcrespo Date 2021-01-19 Time 16:17 Sent To  
Notes
2021-01-19 16:21:4901/19/21 REVIEWED FOR CODE COMPLIANCE (GAS)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-12-22 Cont ID  
Sent By lcrespo Date 2020-12-22 Time 11:13 Rev Time 0.00
Received By lcrespo Date 2020-12-22 Time 11:13 Sent To  
Notes
2020-12-22 11:12:2212/22/20 1ST GAS REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. CITY RECORDS SHOW AN EXISTING GAS SYSTEM AT THIS
 PROPERTY. THE BTU LOAD OF THE CURRENT GAS SYSTEM MUST
 BE ADDED TO THE TOTAL BTU LOAD ON THE SYSTEM TO ENSURE
 THE EXISTING SYSTEM IS SIZED CORRECTLY. IF UNDERSIZED,
 THE EXISTING SYSTEM MUST BE REDONE TO ENSURE A SAFE
 OPERATING SYSTEM. SUBMIT A GAS PIPING RISER DIAGRAM
 THAT SHOWS THE TYPE OF EXISTING APPLIANCE, THE BTU LOAD
 OF EACH APPLIANCE, THE PIPE SIZE AND TYPE OF PIPE TO
 EACH APPLIANCE, AND THE DISTANCE OF THE LONGEST LENGTH
 OF PIPING FROM THE POINT OF DELIVERY TO THE MOST REMOTE
 OUTLET AND THE LOAD OF THE SECTION. NOTE: IF THE
 EXISTING SYSTEM IS PRESSURE IS 2 PSI, A LINE PRESSURE
 REGULATOR IS REQUIRED AT ALL THE EXISTING APPLIANCES
 PER THE 2017 FBC R SECS. G2412.4, G2412.8, G2413.1,
 G2413.2, G2413.3.
  
 2 INDICATE THE PLAN IN WHICH THE GAS CODE'S SIZING
 TABLES ARE BEING USED FOR THE SYSTEM PER THE WPB
 AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 3. THE TYPE OF PIPE MENTION IS NOT APPROVED TO BE
 INSTALLED UNDERGROUND. YOU MAY USE TRAC PIPE OR PE FOR
 UNDERGROUND AND CSST OR METAL PIPE ABOVE GROUND, SO
 PLEASE CLARIFY PER THE WPB AMENDMENTS TO THE FBC SEC.
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 4. GAS RISER DIAGRAM REQUIRED, SO PLEASE SUBMIT AN
 ISOMETRIC DRAWING THAT CLEARLY SHOWS THE LENGTH OF ALL
 CUT SECTIONS OF PIPE PER 2017 FBC RES. SECS. G2413.4.1,
 G2413.4.2.
  
 5. SHOW THE TYPE OF PIPE MATERIAL BEING USED, ALL PIPE
 SIZES, AND THE CORRESPONDING EHD NUMBER OF THE
 CORRUGATED STAINLESS-STEEL OR TRAC PIPE TUBING (IF
 APPLICABLE) FOR EACH PIPE SIZE PER THE WPB AMENDMENTS
 TO THE FBC SEC.107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS.
 6. A LICENSED CONTRACTOR MUST REQUIRE A SUB GAS PERMIT
 FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC
 SEC. 105.1.
  
 7. TYPE OF GAS (LP OR NATURAL) PER THE WPB AMENDMENTS
 TO THE FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS.
  
 8. SHOW ALL MP (STEP-DOWN) REGULATORS' LOCATION. A
 LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY
 AHEAD OF EACH MP REGULATOR. 2017 FBC RES. SEC. G2420.4.
  
 9. SHOW THE DISTANCE FROM THE POINT OF DELIVERY (GAS
 METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND OR SYSTEM PER THE 2017 FBC
 RES. SEC. G2413.4.1.
  
 10. IF THIS TANKLESS UNIT CALL FOR A 10.5" WATER COLUMN
 AND THE SERVICE METER DISCHARGES IS A 12" WATER COLUMN
 REQUIRING A REGULATOR FOR THIS UNIT AS PER
 MANUFACTURER'S SPECIFICATION. SUBMIT MANUFACTURER'S
 SPECIFICATIONS FOR THE PRESSURE REGULATORS. REGULATORS
 INSTALLED ON THE BUILDING'S EXTERIOR SHALL BE APPROVED
 FOR OUTDOOR INSTALLATION PER THE 2017 FBC RES. SEC.
 G2421.1.
  
 10. INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM
 ON THE PLAN PER THE 2017 FBC RES. SEC. G2413.2.
  
 11. SUBMIT MANUFACTURER'S SPECIFICATION
 SHEETS/INSTALLATION MANUAL FOR GAS TANK-LESS TO VERIFY
 COMPLIANCE WITH 2017 FBC RES. SEC. G2408.1.
  
 12. PLEASE SHOW ALL REGULATORS, UNIONS IN FRONT OF
 REGULATOR 1' OF EITHER SIDE, DRIP LEG, LABEL SHUT OFF
 VALVES WITH THEM LABELED PER THE 2017 FBC RES. SEC
 G2421.2
  
 13. ON THE PLAN, PLEASE THE LOCATION OF THE TANK-LESS
 WATER HEATER AND THE LOCATION AND DISTANCE OF ANY
 OPERABLE DOORS OR WINDOWS IN RELATION TO THE WATER
 HEATER. THE LOCATION OF THE WATER HEATER SHALL COMPLY
 WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE
 HOUSE PLAN CAN BE HAND-DRAWN PER THE WPB AMENDMENTS TO
 THE FBC SEC. 107.2.1. INFORMATION ON CONSTRUCTION
 DOCUMENTS.
  
 NOTE: YOU MAY CHOOSE TO HAVE A GAS REVIEW DONE THIS
 TIME AND ADDRESS THE COMENTS ABOVE. THIS WILL HAVE THE
 GAS APPROVE FOR A SUB PERMIT, OR IF YOU DECIDED NOT TO
 ADDRESS THESE COMMENTS, PLEASE PUT A NOTE ON THE GAS
 HEATER ( A SEPARATE PERMIT BY A LICENSED CONTRACTOR FOR
 THE GAS SYSTEM). THEN PLEASE TAKE OFF ANY GAS SHOWN ON
 PLANS; THESE COMMENTS CAN BE FORWARD TO THE GAS
 CONTRACTOR FOR REFERENCE. AN N WILL BE PUT ON THIS
 REVIEW, WHICH STANDS FOR NOT REQUIRED BUT, A SUB PERMIT
 WON'T BE ISSUED UNIT A REVIEW IS DONE FOR THAT SUB
 PERMIT, SO PLEASE BE ADVISED ON THIS PROCEDURE.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2021-01-21 Cont ID  
Sent By fmittner Date 2021-01-21 Time 12:15 Rev Time 0.00
Received By fmittner Date 2021-01-21 Time 12:15 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2020-12-28 Cont ID  
Sent By fmittner Date 2020-12-28 Time 13:31 Rev Time 0.00
Received By fmittner Date 2020-12-28 Time 13:31 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2020-12-03 Cont ID  
Sent By fmittner Date 2020-12-03 Time 12:40 Rev Time 0.00
Received By fmittner Date 2020-12-03 Time 12:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-01-21 Cont ID  
Sent By shill Date 2021-01-21 Time 12:55 Rev Time 0.00
Received By shill Date 2021-01-15 Time 16:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-12-29 Cont ID  
Sent By shill Date 2020-12-29 Time 18:11 Rev Time 0.00
Received By shill Date 2020-12-10 Time 18:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-12-09 Cont ID  
Sent By shill Date 2020-12-09 Time 08:44 Rev Time 0.00
Received By shill Date 2020-11-23 Time 09:44 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2021-01-27 Cont ID  
Sent By ccarvaja Date 2021-01-27 Time 08:28 Rev Time 0.00
Received By ccarvaja Date 2021-01-20 Time 13:56 Sent To  
Notes
2021-01-27 08:30:2901/27/21 RECEIPT MU 2021 2879 - $546.52 - PAID. CC
2021-01-20 13:57:1201/20/21 EMAILED PALM BEACH COUNTY IMPACT FEE OFFICE.
 PERMIT READY TO BE REVIEWED, IF QUESTIONNAIRE UPLOADED.
 CC

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-12-28 Cont ID  
Sent By cthroop Date 2020-12-28 Time 11:51 Rev Time 0.00
Received By cthroop Date 2020-12-28 Time 11:51 Sent To  
Notes
2020-12-28 11:52:32PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2021-01-19 Cont ID  
Sent By medwards Date 2021-01-19 Time 06:01 Rev Time 0.00
Received By medwards Date 2021-01-19 Time 06:01 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-12-22 Cont ID  
Sent By medwards Date 2020-12-22 Time 06:42 Rev Time 0.00
Received By medwards Date 2020-12-22 Time 06:42 Sent To  
Notes
2020-12-22 06:43:34APPROVED WITH PRIVISO: ANCHORAGE OF CONDENSING UNIT
 MUST MEET FBC RES M1307.2 ME
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-11-24 Cont ID  
Sent By medwards Date 2020-11-24 Time 08:54 Rev Time 0.00
Received By medwards Date 2020-11-24 Time 08:46 Sent To  
Notes
2020-11-24 08:54:431ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20110914
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE A CODE COMPLIANT MECHANICAL DRAWING
 SHOWING HOW THIS CHANGE OF USE WILL BE CONDITIONED. FBC
 107.2
  
 2) PLEASE PROVIDE ENERGY CALCULATIONS FOR THIS SPACE.
 FBC EC 101.5.1.1.2
  
 3) PLEASE PROVIDE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FBC EC R403.7.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2021-01-19 Cont ID  
Sent By lcrespo Date 2021-01-19 Time 16:18 Rev Time 0.00
Received By lcrespo Date 2021-01-19 Time 16:17 Sent To  
Notes
2021-01-19 16:19:4601/19/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-12-22 Cont ID  
Sent By lcrespo Date 2020-12-22 Time 11:13 Rev Time 0.00
Received By lcrespo Date 2020-12-22 Time 08:03 Sent To  
Notes
2020-12-22 09:49:2112/22/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. THESE ARE MULTI-FAMILY DWELLINGS. THE WATER USERS
 WILL BE REQUIRED TO INSTALL A BACKFLOW PREVENTION
 ASSEMBLY AT THE POINT OF DELIVERY THAT IS LEAD-FREE AND
 A CURRENT YEAR CERTIFICATION PER THE CITY OF WEST PALM
 CROSS UTILITIES DEPARTMENT AND THEIR CONNECTION CONTROL
 PROGRAM.
  
 2. A LICENSED CONTRACTOR MUST REQUIRE SUB PLUMBING AND
 GAS PERMITS FOR THE SCOPE OF WORK PER THE WPB
 AMENDMENTS TO THE FBC SEC. 105.1.
  
 3. ON SHEET A-1;
 A. THE PLUMBING ISOMETRIC SHOW TWO AIR ADMITTANCE
 VALVE, THE SYSTEM MUST HAVE A VENT THROUGH THE ROOF. A
 MINIMUM OF ONE STACK VENT OR VENT STACK EXTENDED TO THE
 OUTDOORS TO THE OPEN AIR PER THE FBC SEC. P 918.7. SHOW
 COMPLIANCE WITH THE PLANS.
  
 B. PLEASE SHOW DIMENSION BETWEEN FIXTURES INSTALLATION
 TO CONFORM TO THE 2017 FBC SEC. R 2705.1 (5).
  
 C. HOT WATER LINES NOT IN CONDITION SPACE SHALL BE
 INSULATED WITH A MINIMUM R-3 PER THE 2017 FBC SEC. RE
 403.5.3.
  
 D. HOT GAS HEATER IF CONDENSATE NEEDS TO BE 1' AWAY
 FROM STRUCTURE PER THE 2017 FBC SEC. R318.5.
  
 4. PLEASE PROVIDE MANUFACTURES INSTALLATION INSTRUCTION
 FOR TH GAS WATER HEATER PER THE WPB AMENDMENTS TO THE
 FBC 107.2.1.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-11-30 Cont ID  
Sent By ccole Date 2020-11-30 Time 16:35 Rev Time 0.00
Received By ccole Date 2020-11-30 Time 16:22 Sent To  
Notes
2020-11-30 16:35:371ST REVIEW FBC-2017 RES.
 PERMIT- 20110914
 11/30/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SUBMIT PLUMBING PLANS AND SPECIFICATIONS INCLUDING A
 SANITARY RISER DRAWING- SECTION 107.3.5.3 WPB.
  
 2) PROVIDE A PLUMBING SUB-PERMIT APPLICATION- SECTION
 105.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2021-01-19 Cont ID  
Sent By cthroop Date 2021-01-19 Time 15:49 Rev Time 0.00
Received By cthroop Date 2021-01-19 Time 14:31 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2020-12-23 Cont ID  
Sent By cthroop Date 2020-12-23 Time 11:20 Rev Time 0.00
Received By cthroop Date 2020-12-23 Time 11:07 Sent To  
Notes
2020-12-23 11:23:04PLAN REVIEW / ROOFING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2014 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE ENHANCED UPLIFT PRESSURE REQUIREMENTS FOR
 PERIMETER AND CORNER AREAS PREPARED BY A DESIGN
 PROFESSIONAL PER NOTE #7, NOA 20-0131.01.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-01-19 Cont ID  
Sent By cthroop Date 2021-01-19 Time 15:33 Rev Time 0.00
Received By cthroop Date 2021-01-19 Time 14:30 Sent To  
Notes
2021-01-19 15:34:40HARD COPY OF PLANS WITH SIG AND SEAL DROPPED OFF AT
 CITY HALL ON 1/19/2021 PER JO. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-12-23 Cont ID  
Sent By cthroop Date 2020-12-23 Time 11:18 Rev Time 0.00
Received By cthroop Date 2020-12-23 Time 07:25 Sent To  
Notes
2020-12-23 11:19:19PLAN REVIEW / SIGNATURES
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR
 DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL
 WET SEAL AND SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-11-28 Cont ID  
Sent By cthroop Date 2020-11-28 Time 13:13 Rev Time 0.00
Received By cthroop Date 2020-11-28 Time 12:47 Sent To  
Notes
2020-11-28 13:15:18PLAN REVIEW / SIGNATURES
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. NO PLANS SUBMITTED FOR REVIEW.
  
 2. NEW SIGNATURE REVIEW REQUIRED.

Review Stop Z ZONING
Rev No 3 Status P Date 2021-01-21 Cont ID  
Sent By fmittner Date 2021-01-21 Time 12:15 Rev Time 0.00
Received By fmittner Date 2021-01-21 Time 12:15 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2020-12-28 Cont ID  
Sent By fmittner Date 2020-12-28 Time 13:31 Rev Time 0.00
Received By fmittner Date 2020-12-28 Time 13:31 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2020-12-03 Cont ID  
Sent By rthermid Date 2020-12-03 Time 12:40 Rev Time 0.00
Received By fmittner Date 2020-12-03 Time 12:40 Sent To  
Notes
***NONE***