2020-12-15 10:38:50 | 1ST REVIEW FBC-2017 RES. FUEL GAS |
| PERMIT- 20120071 |
| 12/15/2020 |
| |
| CODES IN EFFECT: |
| FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH |
| EDITION 2017 |
| FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 |
| FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| 2017 |
| FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH |
| FS- FLORIDA STATUTES |
| FAC- FLORIDA ADMINISTRATIVE CODE |
| WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| EDITION 2017 |
| |
| PLAN REVIEW RESULTS: DENIED. |
| |
| 1) PROVIDE A GAS RISER DRAWING- SECTION 107.3.5.3 WPB. |
| THE RISER SHALL PROVIDE THE FOLLOWING INFORMATION: |
| |
| A) DELIVERY PRESSURE AT THE METER- SECTIONS G2413.1 FBC |
| RES. |
| |
| B) TOTAL DEVELOPED LENGTH OF THE PIPING FROM THE METER |
| TO THE MOST REMOTE GAS OUTLET- SECTION G2413.4.1. |
| |
| D) BRANCH AND CUT PIPING LENGTHS- SECTION G2413.4.2. |
| |
| E) INDIVIDUAL GAS LOADS AT OUTLETS AND TOTAL LOAD OF |
| THE SYSTEM- SECTIONS G2412.3, G2412.4, & G2413.2 FBC |
| RES. |
| |
| F) LOCATIONS OF REGULATORS AND OUTLET PRESSURES- |
| SECTIONS G2421.1 & G2421.2. |
| |
| G) PIPE SIZING TABLES- SECTION G2413.3. |
| |
| 2) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE WATER |
| HEATERS AND RANGE SHOWING THE BTUH LOAD CAPACITIES AND |
| INLET PRESSURES- SECTIONS G2447.1 & G2448.1 FBC RES. |
| |
| 3) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE |
| REGULATORS MARKED OR HIGHLIGHTED TO SHOW THE SELECTED |
| MODELS, INLET AND OUTLET PIPE SIZES AND PRESSURES, AND |
| ORIFICE SIZES- SECTIONS G2421.1 & G2421.2 FBC RES. |
| |
| 4) SHEET GP-2: PLEASE SHOW THE CLEARANCE DISTANCE FROM |
| THE WATER HEATER VENT OPENINGS TO THE WINDOW- SECTIONS |
| G2427.8 & G2448.1 FBC RES. |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| |
| CHRISTOPHER L. COLE |
| MECHANICAL/PLUMBING PLANS EXAMINER |
| 401 CLEMATIS STREET |
| WEST PALM BEACH FL 33401 |
| 561-805-6719 |
| [email protected] |
| |