Plan Review Stops For Permit 20110839 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2021-04-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-24 |
Time |
08:29 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-24 |
Time |
08:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2021-02-11 |
|
|
Cont ID |
|
Sent By |
chtroop |
Date |
2021-02-11 |
Time |
16:56 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-02-11 |
Time |
16:23 |
Sent To |
|
|
Notes |
2021-02-11 16:58:13 | PLAN REVIEW / BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 3RD REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | RE: NOTE ON SURVEY AND GENERAC SETBACK REQUIREMENTS. | | | | 1. LOCATION OF GENERATOR TO BUILDING OPENINGS SHALL BE | | 10 FEET PER R303.5.1 | | | | R303.5.1 INTAKE OPENINGS. | | MECHANICAL AND GRAVITY OUTDOOR AIR INTAKE OPENINGS | | SHALL BE LOCATED NOT LESS THAN 10 FEET (3048 MM) FROM | | ANY HAZARDOUS OR NOXIOUS CONTAMINANT, SUCH AS VENTS, | | CHIMNEYS, PLUMBING VENTS, STREETS, ALLEYS, PARKING LOTS | | AND LOADING DOCKS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-12-21 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-12-21 |
Time |
16:24 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-12-21 |
Time |
16:18 |
Sent To |
|
|
Notes |
2021-01-19 07:02:07 | PLAN REVIEW / BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 2ND REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. LOCATION OF GENERATOR TO BUILDING OPENINGS SHALL BE | | 10 FEET PER R303.5.1 | | | | R303.5.1 INTAKE OPENINGS. | | MECHANICAL AND GRAVITY OUTDOOR AIR INTAKE OPENINGS | | SHALL BE LOCATED NOT LESS THAN 10 FEET (3048 MM) FROM | | ANY HAZARDOUS OR NOXIOUS CONTAMINANT, SUCH AS VENTS, | | CHIMNEYS, PLUMBING VENTS, STREETS, ALLEYS, PARKING LOTS | | AND LOADING DOCKS. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-11-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-28 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-28 |
Time |
13:18 |
Sent To |
|
|
Notes |
2020-11-28 14:02:20 | PLAN REVIEW / BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. LOCATION OF GENERATOR TO BUILDING OPENINGS SHALL BE | | 10 FEET PER R303.5.1 | | | | R303.5.1 INTAKE OPENINGS. | | MECHANICAL AND GRAVITY OUTDOOR AIR INTAKE OPENINGS | | SHALL BE LOCATED NOT LESS THAN 10 FEET (3048 MM) FROM | | ANY HAZARDOUS OR NOXIOUS CONTAMINANT, SUCH AS VENTS, | | CHIMNEYS, PLUMBING VENTS, STREETS, ALLEYS, PARKING LOTS | | AND LOADING DOCKS. | | | | 2. CONCRETE PAD DETAIL IS ILLEGIBLE. | | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-12-22 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2020-12-22 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2020-12-22 |
Time |
15:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-12-04 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2020-12-04 |
Time |
17:21 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2020-12-04 |
Time |
17:21 |
Sent To |
|
|
Notes |
2020-12-04 17:26:16 | CODES IN EFFECT | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: FAILED | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PLEASE PROVIDE SPECS (CUT SHEETS) FOR ATS'S FBC | | 107.2.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | | | ENRIQUE QUINONEZ | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-04-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-26 |
Time |
08:10 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-07 |
Time |
15:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-02-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-02-11 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-01-27 |
Time |
23:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-01-06 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-01-06 |
Time |
15:01 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-12-16 |
Time |
11:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-12-04 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2020-12-04 |
Time |
17:23 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2020-11-19 |
Time |
17:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2021-04-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-04-24 |
Time |
08:29 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-04-24 |
Time |
08:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2021-02-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-02-11 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-02-11 |
Time |
16:23 |
Sent To |
|
|
Notes |
2021-02-11 16:56:37 | PLAN REVIEW / SIGNATURES | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 3RD REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | RE: CONCRETE PAD DESIGN SHEET 1 | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | SIGNATURE. | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | WET SEAL AND SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-12-21 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-12-21 |
Time |
16:24 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-12-21 |
Time |
16:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-11-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-28 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-28 |
Time |
13:18 |
Sent To |
|
|
Notes |
2020-11-28 13:58:45 | PLAN REVIEW / SIGNATURES | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | RE: CONCRETE PAD DESIGN | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | SIGNATURE. | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | WET SEAL AND SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2021-04-26 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2021-04-26 |
Time |
|
Rev Time |
0.00 |
Received By |
rthermid |
Date |
2021-04-26 |
Time |
|
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2021-01-05 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2021-01-05 |
Time |
|
Rev Time |
0.00 |
Received By |
rthermid |
Date |
2021-01-05 |
Time |
|
Sent To |
I |
|
Notes |
2021-01-05 12:08:52 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: 1/5/2021 | | ________________________________________ | | | | REVIEW STATUS: PASSED WITH PROVISOS | | ________________________________________ | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | PROVISOS: | | | | 1. THE GENERATOR MUST BE SETBACK A MINIMUM OF 9.3 FEET | | FROM THE EASTERNMOST (REAR) PROPERTY LINE. | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | TTY: 800.955.8771 | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-12-03 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-12-03 |
Time |
|
Rev Time |
|
Received By |
rthermid |
Date |
2020-12-03 |
Time |
|
Sent To |
I |
|
Notes |
2020-12-03 08:25:31 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: 12/3/2020 | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. PURSUANT THE CITY OF WEST PALM BEACH ZONING AND | | LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION | | 94-305(B)(4): MECHANICAL EQUIPMENT MAY NOT PROJECT MORE | | THAN 4 FEET INTO A REQUIRED SETBACK. IN THIS CASE, THE | | REQUIRED SETBACK IS 13.3 FEET. THIS MEANS THAT THE | | GENERATOR MUST BE A MINIMUM OF 9.3 FEET FROM THE REAR | | PROPERTY LINE. | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | LIKE TO RESUBMIT ELECTRONICALY, EMAIL | | [email protected] AND REQUEST TO HAVE YOUR | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOGIN | | INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | ARE FINISHED UPLOADING. | | | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | TTY: 800.955.8771 | | E: [email protected] | | W: WPB.ORG | | |
|
|