Plan Review Details - Permit 20110746
Plan Review Stops For Permit 20110746
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-12-08 Cont ID  
Sent By rmcphers Date 2020-12-08 Time 13:46 Rev Time 0.00
Received By rmcphers Date 2020-12-08 Time 13:34 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-01-05 Cont ID  
Sent By jleahy Date 2021-01-05 Time 13:39 Rev Time 0.00
Received By jleahy Date 2021-01-05 Time 13:34 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-12-03 Cont ID  
Sent By ppetty Date 2020-12-03 Time 11:47 Rev Time 0.00
Received By ppetty Date 2020-12-03 Time 11:16 Sent To  
Notes
2020-12-03 11:46:56CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1.215.5 PROVIDE WIRE SIZES
 2.680.8 OVERHEAD CONDUCTOR CLEARANCES, SEPARATE PERMIT
 REQUIRED FOR WORK ON SERVICE
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 SINCERELY,
  
 PHIL PETTY
 CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER
  
 561-805-6742
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2020-12-17 Cont ID  
Sent By fmittner Date 2020-12-17 Time 13:02 Rev Time 0.00
Received By fmittner Date 2020-12-17 Time 13:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-01-05 Cont ID  
Sent By jleahy Date 2021-01-05 Time 13:39 Rev Time 0.00
Received By jleahy Date 2020-12-23 Time 12:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-12-23 Cont ID  
Sent By jleahy Date 2020-12-23 Time 10:55 Rev Time 0.00
Received By jleahy Date 2020-11-24 Time 10:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2020-12-03 Cont ID  
Sent By lcrespo Date 2020-12-03 Time 12:07 Rev Time 0.00
Received By lcrespo Date 2020-12-03 Time 11:59 Sent To  
Notes
2020-12-03 12:07:2712/03/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING/POOL)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-12-28 Cont ID  
Sent By shill Date 2020-12-28 Time 12:55 Rev Time 0.00
Received By shill Date 2020-12-28 Time 12:55 Sent To  
Notes
2020-12-28 12:56:00PASSED PER FBPE EMERGENCY ORDER
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-12-03 Cont ID  
Sent By medwards Date 2020-12-03 Time 07:00 Rev Time 0.00
Received By medwards Date 2020-12-03 Time 07:00 Sent To  
Notes
2020-12-03 07:04:04THE POOL DRAWINGS SUBMITTED ARE A COPY OF THE ORIGINAL
 DIGITALLY SIGNED AND SEALED DRAWINGS. WE MUST HAVE THE
 ORIGINAL DIGITALLY SIGNED AND SEALED DRAWINGS SUBMITTED
 ELECTRONICALLY OR A A PAPER COPY OF THE ENGINEERS STAMP
 AND SIGNATURE CAN BE DROPPED OFF AT OUR OFFICE.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2020-12-17 Cont ID  
Sent By fmittner Date 2020-12-17 Time 13:02 Rev Time 0.00
Received By fmittner Date 2020-12-17 Time 13:02 Sent To  
Notes
***NONE***