Plan Review Details - Permit 20110593
Plan Review Stops For Permit 20110593
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2020-11-23 Cont ID  
Sent By ccole Date 2020-11-23 Time 15:37 Rev Time 0.00
Received By ccole Date 2020-11-23 Time 07:09 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-11-17 Cont ID  
Sent By ccole Date 2020-11-17 Time 14:51 Rev Time 0.00
Received By ccole Date 2020-11-17 Time 14:51 Sent To  
Notes
2020-11-17 14:53:361ST REVIEW FBC-2017 RES. FUEL GAS
 PERMIT- 20110593
 11/17/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) GAS RISER DRAWING:
 A) CORRECT THE BTU LOAD OF THE GENERATOR LOAD AND THE
 TOTAL LOAD OF THE SYSTEM- SECTIONS G2412.3, G2412.4, &
 G2413.2 FBC RES. THE APPROVED GENERATOR PERMIT- 2009009
 SHOWS A 327,000 BTUH LOAD.
 B) INDICATE A NEW OR EXISTING GAS METER AND SHOW THE
 DELIVERY PRESSURE- G2413.1
 C) PROVIDE THE TOTAL LENGTH DEVELOPED LENGTH OF THE
 PIPING FROM THE METER TO THE MOST REMOTE OUTLET-
 G2413.4.1 AND G2413.4.2.
 D) SHOW THE LOCATIONS OF REGULATORS AND THEIR OUTLET
 PRESSURES- G2421.1 & G2421.2. PLEASE NOTE THAT THE
 GENERATOR SPECS INDICATE AN INPUT PRESSURE OF 3.5- 7
 IN. W.C.
  
 2) PROVIDE VENTING DIAGRAMS FOR THE TANKLESS WATER
 HEATER, RANGE AND DRYER, OR INDICATE TO BE DONE UNDER A
 SEPARATE PERMIT BY A LICENSED MECHANICAL CONTRACTOR-
 SECTIONS 105.1, 107.2.1, 107.3.5.3 WPB. SHOW CLEARANCE
 DISTANCES FOR THE WATER HEATER PER THE MANUFACTURER?S
 SPECIFICATIONS- SECTION G2448.1 FBC RES.
  
 3) SUBMIT SPEC SHEETS FOR THE APPLIANCES OR PROVIDE A
 NOTE TO BE ONSITE FOR INSPECTION- SECTION 107.2.1 WPB.
  
 4) THE $3000.00 VALUE APPEARS LOW FOR THE SCOPE OF
 WORK. SUBMIT A COPY OF A SIGNED CONTRACT AND/OR
 ESTIMATES AND INVOICES TO VERIFY THE TOTAL COST
 INCLUDING LABOR, MATERIAL, AND THE COST OF THE
 APPLIANCES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2020-11-23 Time   Rev Time 0.00
Received By ccarvaja Date 2020-11-18 Time 09:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-11-17 Cont ID  
Sent By ccole Date 2020-11-17 Time 14:54 Rev Time 0.00
Received By ccole Date 2020-11-16 Time 11:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2020-11-23 Cont ID  
Sent By ccole Date 2020-11-23 Time 15:37 Rev Time 0.00
Received By ccole Date 2020-11-23 Time 07:09 Sent To  
Notes
2020-11-23 15:38:05SEPARATE PERMIT AND PLANS REQUIRED FOR PLUMBING.

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-11-17 Cont ID  
Sent By ccole Date 2020-11-17 Time 14:58 Rev Time 0.00
Received By ccole Date 2020-11-17 Time 14:53 Sent To  
Notes
2020-11-17 14:58:501ST REVIEW FBC-2017 RES. PLUMBING.
 PERMIT-20110593
 11/17/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE A PLUMBING SUB-PERMIT FOR INSTALLATION OF
 THE WATER HEATER- SECTION 105.1 WPB.
  
 2) PROVIDE A WATER RISER SHOWING THE PLUMBING PIPING
 CONNECTIONS TO THE NEW WATER HEATER- SECTION 107.3.5.3
 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-11-23 Cont ID  
Sent By ccole Date 2020-11-23 Time 15:42 Rev Time 0.00
Received By ccole Date 2020-11-23 Time 15:42 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-11-17 Cont ID  
Sent By ccole Date 2020-11-17 Time 14:54 Rev Time 0.00
Received By ccole Date 2020-11-17 Time 14:54 Sent To  
Notes
***NONE***