Plan Review Stops For Permit 20110522 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2021-01-05 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-01-05 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-01-05 |
Time |
15:44 |
Sent To |
|
|
Notes |
2021-01-05 15:45:06 | WRONG ADDRESS SUBMITTED ORIGINALLY, NEW SUITE 106 |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2020-11-17 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-11-17 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-11-17 |
Time |
16:41 |
Sent To |
|
|
Notes |
2020-11-17 16:42:03 | WIL THE SUITES BE MERGED INTO ONE SUITE, PLEASE CONTACT | | [email protected] TO DISCUSS ADDRESSING |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
3 |
Status |
P |
Date |
2020-12-04 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-12-04 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
P |
Date |
2020-12-04 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-12-04 |
Time |
10:05 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2020-11-25 |
|
|
Cont ID |
|
Sent By |
|
Date |
2020-01-25 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-11-25 |
Time |
08:02 |
Sent To |
|
|
Notes |
2020-11-25 09:44:17 | COMMERCIAL ASBESTOS | | | | TO THE BUILDING CONTRACTOR: | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-01-27 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2021-01-27 |
Time |
10:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-01-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-01-09 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2021-01-09 |
Time |
14:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-11-25 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-11-25 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-11-25 |
Time |
08:02 |
Sent To |
|
|
Notes |
2020-11-25 09:42:33 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | SERVICES/ BUILDING DIVISION | | 2017 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 20110522 | | ADD: 700 S. ROSEMARY AVE. SUITES 202 & 204 | | CONT: TRM CONSTRUCTION MANAGEMENT, INC. | | TEL: 772-905-2727 | | E-MAIL: [email protected] | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: WED. NOV. 25TH/ 2020 | | ACTION: DENIED | | | | 1A) THERE SEEMS TO BE CONFUSION AS TO WHERE WORK IS TO | | BE ACCOMPLISHED UNDER THIS PERMIT. THE PERMIT | | APPLICATION INDICATES 700 S. ROSEMARY AVE. SUITES | | 200,201,202 & 204 WHEREAS THE TITLEBLOCK OF THE PLANS | | SHOWS THE ADDRESS OF 700 S. ROSEMARY AVE. SUITE # 106. | | WHILE THE PLANS SHOW WORK IN ALL 3 LOCATIONS. PLEASE | | CLARIFY ON THE PERMIT APPLICATION AS WELL AS THE | | TITLEBLOCK OF THE PLANS WHERE WORK IS TO BE | | ACCOMPLISHED UNDER THIS PERMIT. | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION 107.2.1 INFORMATION ON CONSTRUCTION | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE OF | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | EXTENT OF THE WORK PROPOSED. | | | | 1B) THE PERMIT APPLICATION STATES THAT THE WORK UNDER | | THIS PERMIT IS MODIFICATIONS TO THE SHELL SPACE? IF ALL | | 3 SPACES SUITES 106, 202 & 204ALL GOING TO REMAIN SHELL | | SPACES OR ARE SUITES 202 & 204 GOING TO BE USED FOR | | STORAGE AND NEED TO BE CLASSIFIED AS EITHER S1 OR S2? | | ADDITIONAL INFORMATION IS REQUIRED. CURRENTLY THE PLANS | | STATE THEY ARE A BUSINESS OCCUPANCY, WITH AN OCCUPANT | | LOAD OF 9 OCCUPANTS. IN BOTH CASES THERE IS OVER 900 | | SQ. FT. IN EACH SPACE, WHEN THERE IS A FRACTION OF AN | | OCCUPANT YOU ROUND UP SO THE OCCUPANT LOAD WOULD BE TEN | | IN BOTH CASES FOR SUITE 202 & 204. 2017 FBC-B TABLE | | 1004.1.2 & 2015 IBC COMMENTARY. | | | | 2) SHEET A1.1.1 NOTES 19,20, & 21 ALL HAVE NOTES ABOUT | | FLOOR REMOVAL, AND OR FLOOR DEPRESSIONS. THE SYMBOL FOR | | THESE FLOOR PENETRATIONS ARE IN OTHER AREAS OF THE | | TENANT SPACE AND APPEARS TO DO WITH NEW FLOOR OUTLETS | | BUT THE PLAN LEGEND DOES NOT IDENTIFY THESE AREAS OF | | THE FLOOR ARE REMOVAL OF FLOOR SLAB. ADDITIONAL | | INFORMATION IS REQUIRED. 107.2.1.2 ADDITIONAL | | INFORMATION IS REQUIRED. | | | | 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | 19 | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | 561-718-9724. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-01-26 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-01-26 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-01-26 |
Time |
14:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-12-15 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-12-15 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-12-15 |
Time |
10:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2020-11-20 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-11-20 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-11-20 |
Time |
11:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-01-27 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
ccarvaja |
Date |
2021-01-26 |
Time |
10:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-01-22 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-01-22 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-01-04 |
Time |
14:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-12-16 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-11-17 |
Time |
16:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2021-01-14 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-01-14 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-01-14 |
Time |
09:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-12-10 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2020-12-10 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2020-12-10 |
Time |
12:47 |
Sent To |
|
|
Notes |
2020-12-10 14:23:53 | PLAN DENIED | | PROVIDE FRESH AIR CALCULATIONS PER SECTION TABLE | | 403.3.1.1 | | 2017 FBC (M) | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2021-01-20 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-01-20 |
Time |
17:22 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-01-20 |
Time |
17:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-12-16 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-12-16 |
Time |
17:17 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-12-16 |
Time |
16:13 |
Sent To |
|
|
Notes |
2020-12-16 17:17:33 | 1ST REVIEW FBC-2017 PLUMBING | | PERMIT- 20110522 | | 12/16/2020 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET P101: PLEASE PROVIDE A SLAB REPAIR DETAIL FOR | | SLABS REMOVED TO INSTALL DRAIN AND VENT PIPING- SECTION | | 107.2.1 WPB. | | | | 2) P101: PLEASE NOTE A SEPARATE PERMIT IS REQUIRED FOR | | INSTALLATION OF THE POTABLE WATER SERVICE BACKFLOW | | PREVENTER- SECTION 105.1 AND 107.2.1 WPB. A FL. | | LICENSED PLUMBING CONTRACTOR SHALL OBTAIN A SEPARATE | | PERMIT FOR INSTALLATION OF THE BACKFLOW PREVENTER IN | | ACCORDANCE WITH SECTION 105.1 WPB AND SEC. 90-33 WPB | | CODE OF ORDINANCES. THE DEVICE SHALL BE TESTED AND | | CERTIFIED BY THE WPB UTILITIES DEPARTMENT PRIOR TO | | FINAL INSPECTION BY THE BUILDING DEPARTMENT. PLEASE | | CONTACT THE WPB UTILITIES CENTRAL OPERATIONS DEPT.AT | | 561-822-2210 FOR FURTHER INFORMATION. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-01-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-01-27 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-12-16 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-12-16 |
Time |
17:18 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-12-16 |
Time |
16:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2021-01-26 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2021-01-26 |
Time |
13:44 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2021-01-26 |
Time |
13:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2021-01-22 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2021-01-22 |
Time |
15:19 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2021-01-22 |
Time |
09:52 |
Sent To |
|
|
Notes |
2021-01-22 15:19:18 | FAILED | | | | 1) ELECTRICAL NOTE #2 (PROVIDED 4 TIMES) CALLS OUT A | | WEATHERPROOF J-BOX AND 3/4 INCH CONDUIT WITH PULLWIRE | | STUBBED INTO ACCESSIBLE TENANTS CEILING ARE FOR | | EXTERIOR SIGNAGE. PROVIDE A DETAIL FOR EACH DIFFERENT | | LOCATION SO THAT STAFF CAN VERIFY THAT THIS ELECTRICAL | | CONNECTION COMPLIES WITH THE ROSEMARY SQUARE TENANT | | SIGN CRITERIA REQUIREMENT THAT ALL LIGHTING CONDUIT, | | WIRING, BALLAST BOXES, TRANSFORMERS, AND OTHER | | EQUIPMENT NECESSARY FOR SIGN CONNECTION SHALL BE | | CONCEALED AND NOT VISIBLE TO THE PUBLIC. ***** THE | | COMMENT RESPONSE DOES NOT ADDRESS/VERIFY THAT THE ITEMS | | BEING INSTALLED AS PART OF THE LANDLORD WORK ARE NOT | | VISIBLE FROM THE PUBLIC. ONCE THIS IS VERIFIED, THEN | | STAFF WILL DEAL WITH THE SIGNAGE CONTRACTOR ON THE | | SIGNAGE CONNECTIONS. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | [email protected] | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-12-02 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2020-12-02 |
Time |
15:40 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2020-12-02 |
Time |
15:02 |
Sent To |
|
|
Notes |
2020-12-02 15:41:15 | FAILED | | | | PLEASE CLARIFY WHERE THE WORK IS BEING DONE. THE PERMIT | | AND THE PLANS LIST DIFFERENT ADDRESSES AND THE GROUND | | AND SECOND FLOOR KEY PLANS HIGHLIGHT TWO LOCATIONS THAT | | DO NOT CONNECT. ADDITIONALLY, THE TWO SECOND FLOOR | | BAYS, WHILE ADJACENT, DO NOT INTERNALLY CONNECT. IT | | SEEMS THAT SEPARATE PERMITS FOR EACH LOCATION WILL BE | | REQUIRED. | | | | THE PLANS FOR THE SECOND FLOOR WORK DO NOT MATCH THE | | LOCATION OF THE WORK ON THE SECOND FLOOR KEY PLAN. THE | | KEY, MECHANICAL, ELECTRICAL AND FIRE PROTECTION PLANS | | SHOW A SIGNIFICANTLY SMALLER AREA AND HAS NO STOREFRONT | | WHEN COMPARED TO THE DEMOLITION, ARCHITECTURAL AND LIFE | | SAFETY PLANS. ALL PLANS MUST SHOW THE SAME ACCURATE | | CONDITIONS. | | | | PLEASE PROVIDE A DESCRIPTION OF WHAT IS INTENDED TO | | OCCUR IN EACH OF THE SPACES. | | | | ELECTRICAL NOTE #2 (PROVIDED 4 TIMES) CALLS OUT A | | WEATHERPROOF J-BOX AND 3/4 INCH CONDUIT WITH PULLWIRE | | STUBBED INTO ACCESSIBLE TENANTS CEILING ARE FOR | | EXTERIOR SIGNAGE. PROVIDE A DETAIL FOR EACH DIFFERENT | | LOCATION SO THAT STAFF CAN VERIFY THAT THIS ELECTRICAL | | CONNECTION COMPLIES WITH THE ROSEMARY SQUARE TENANT | | SIGN CRITERIA REQUIREMENT THAT ALL LIGHTING CONDUIT, | | WIRING, BALLAST BOXES, TRANSFORMERS, AND OTHER | | EQUIPMENT NECESSARY FOR SIGN CONNECTION SHALL BE | | CONCEALED AND NOT VISIBLE TO THE PUBLIC. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | [email protected] |
|
|