Plan Review Details - Permit 20110467
Plan Review Stops For Permit 20110467
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-12-04 Cont ID  
Sent By rmcdouga Date 2020-12-04 Time 17:23 Rev Time 0.00
Received By rmcdouga Date 2020-12-04 Time 17:23 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-11-19 Cont ID  
Sent By rmcdouga Date 2020-11-19 Time 16:03 Rev Time 0.00
Received By rmcdouga Date 2020-11-19 Time 16:03 Sent To  
Notes
2020-11-19 16:06:25PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SUBMIT THE REQUIRED TEST REPORTS FOR THE CORK SOUND
 INSULATION INCLUDING FLAME SPREAD AND SMOKE DEVELOPED
 FOR THE APPLICABLE CONSTRUCTION CONDITIONS.
  
 FBC 603.1 FLAME SPREAD - ASTM E 84-09
  
 FBC 1207.2 AIR-BORNE SOUND. ASTM E 90-04
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E 492-09
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-12-04 Cont ID  
Sent By rmcdouga Date 2020-12-04 Time 17:24 Rev Time 0.00
Received By rmcdouga Date 2020-12-04 Time 17:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-11-19 Cont ID  
Sent By rmcdouga Date 2020-11-19 Time 16:03 Rev Time 0.00
Received By rmcdouga Date 2020-11-16 Time 15:48 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-11-19 Cont ID  
Sent By rmcdouga Date 2020-11-19 Time 16:03 Rev Time 0.00
Received By rmcdouga Date 2020-11-19 Time 16:03 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy