Plan Review Details - Permit 20110461
Plan Review Stops For Permit 20110461
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2020-11-29 Cont ID  
Sent By cpuell Date 2020-11-29 Time 07:38 Rev Time 0.00
Received By cpuell Date 2020-11-29 Time 07:38 Sent To  
Notes
2020-11-29 07:39:38MAIN PROPERTYU ADDRESS IS FINE, GUEST HOUSE 20110462
 WILL NEED TO BE ADDRESSED, PLEASE CONTACT
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-11-28 Cont ID  
Sent By cthroop Date 2020-11-28 Time 06:58 Rev Time 0.00
Received By cthroop Date 2020-11-25 Time 16:14 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-01-06 Cont ID  
Sent By equinone Date 2021-01-06 Time 09:35 Rev Time 0.00
Received By equinone Date 2021-01-06 Time 09:35 Sent To  
Notes
2021-01-06 09:39:50GUEST HOUSE UNDER PERMIT 20110461

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-11-30 Cont ID  
Sent By equinone Date 2020-11-30 Time 13:47 Rev Time 0.00
Received By equinone Date 2020-11-30 Time 13:47 Sent To  
Notes
2020-11-30 13:47:57CODES IN EFFECT
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: FAILED.
  
 1) PLEASE SUBMIT ELECTRICAL DRAWINGS FOR GUEST HOUSE
 FBC 107
 2) PLEASE SPECIFY GROUNDING ELECTRODE SYSTEM FOR BOTH
 HOUSE AND GUEST HOUSE NEC 250
 3) GROUNDING CONDUCTOR (BONDING JUMPER) FROM METER TO
 PANEL A SHOULD BE # 4 CU IF SERVICE ENTRANCE CONDUCTORS
 ARE #3/0. NEC 250-102
  
 END OF COMMENTS.
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 SINCERELY,
  
 ENRIQUE QUINONEZ
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2020-11-25 Cont ID  
Sent By ccole Date 2020-11-25 Time 09:12 Rev Time 0.00
Received By ccole Date 2020-11-25 Time 09:12 Sent To  
Notes
2020-11-25 09:16:01A SEPARATE PERMIT AND PLANS ARE REQUIRED FOR THE GAS
 PIPING AND GAS APPLIANCE INSTALLATIONS.
 COMPLETE PLANS AND PRODUCT SUBMITTALS ARE REQUIRED
 INCLUDING A GAS RISER DRAWING, COMBUSTION AIR
 CALCULATIONS, AND VENTING DIAGRAMS.
  
 CCOLE- 11/25/20

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-01-08 Cont ID  
Sent By shill Date 2021-01-08 Time 07:27 Rev Time 0.00
Received By shill Date 2020-12-31 Time 16:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-12-17 Cont ID  
Sent By cpuell Date 2020-12-17 Time 10:05 Rev Time 0.00
Received By cpuell Date 2020-11-19 Time 10:10 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2021-01-14 Cont ID  
Sent By lmarchan Date 2021-01-14 Time 11:15 Rev Time 0.00
Received By lmarchan Date 2020-12-31 Time 16:48 Sent To  
Notes
2021-01-14 11:15:53RECEIPT MU-2021-000934 - $6630.42 - PAID
2020-12-31 16:48:4312/31/20 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-11-24 Cont ID  
Sent By medwards Date 2020-11-24 Time 07:38 Rev Time 0.00
Received By medwards Date 2020-11-24 Time 07:24 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-01-04 Cont ID  
Sent By ccole Date 2021-01-04 Time 09:04 Rev Time 0.00
Received By ccole Date 2021-01-04 Time 08:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-11-25 Cont ID  
Sent By ccole Date 2020-11-25 Time 09:09 Rev Time 0.00
Received By ccole Date 2020-11-25 Time 08:07 Sent To  
Notes
2020-11-25 09:09:511ST REVIEW FBC-2017 RES. PLUMBING
 PERMIT- 20110461
 11/25/20
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET 1A/B SANITARY RISER:
  
 A) THE WET VENTING SYSTEMS FOR THE GUEST HOUSE BATH AND
 BATHS 2 & 3 ARE NOT IN COMPLIANCE WITH SECTION
 P3108.2.1- NOT MORE THAN ONE WET-VENTED FIXTURE DRAIN
 SHALL DISCHARGE UPSTREAM OF THE DRY-VENTED FIXTURE
 DRAIN CONNECTION.
  
 B) WASHER: SHOW A 2 IN. FIXTURE DRAIN CONNECTING TO A 3
 IN. VERTICAL STACK- SECTION 406.2 FBC P.
  
 2) SHOW THE LOCATIONS OF THE WASHER SHUT OFF VALVES AND
 INDICATE THAT THEY WILL BE ACCESSIBLE PER SECTION
 P2903.9.3 FBC RES.
  
 3) WATER HEATER: THE ENERGY FORM R405-2017 INDICATES A
 40-GALLON NATURAL GAS WATER HEATER. SHOW THE LOCATION
 OF THE WATER HEATER ON THE PLAN, PROVIDE AN EQUIPMENT
 SCHEDULE AND SUBMIT MANUFACTURER'S SPECIFICATIONS-
 SECTION G2448.1 FBC RES. PLEASE NOTE A SEPARATE PERMIT
 AND PLANS ARE REQUIRED FOR THE GAS PIPING TO THE WATER
 HEATER AND ALL OTHER GAS FIRED APPLIANCES AND
 EQUIPMENT- SECTIONS 105.1 AND 107.2.1 WPB. THE GAS
 PLANS SHALL INCLUDE COMBUSTION AIR CALCULATIONS AND
 VENTING PLANS FOR ALL GAS-FIRED APPLIANCES.
  
 4) PROVIDE A WATER RISER- SECTION 107.3.5.3 WPB.
  
 5) PROVIDE SHOWER PAN DETAILS- SECTION P2709.2 FBC RES.
  
 6) BACKFLOW PREVENTER FOR POTABLE WATER SERVICE: PLEASE
 NOTE A FL. LICENSED PLUMBING CONTRACTOR SHALL OBTAIN A
 SEPARATE PERMIT FOR INSTALLATION OF THE BACKFLOW
 PREVENTER IN ACCORDANCE WITH SECTION 105.1 WPB AND SEC,
 90-33 WPB CODE OF ORDINANCES. THE DEVICE SHALL BE
 TESTED AND CERTIFIED BY THE WPB UTILITIES DEPARTMENT
 PRIOR TO FINAL INSPECTION BY THE BUILDING DEPARTMENT.
 PLEASE CONTACT THE WPB UTILITIES CENTRAL OPERATIONS
 DEPT. AT 561-822-2210 FOR FURTHER INFORMATION.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2020-11-28 Cont ID  
Sent By cthroop Date 2020-11-28 Time 06:50 Rev Time 0.00
Received By cthroop Date 2020-11-25 Time 16:14 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-01-06 Cont ID  
Sent By equinone Date 2021-01-06 Time 09:38 Rev Time 0.00
Received By equinone Date 2021-01-06 Time 09:37 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-11-25 Cont ID  
Sent By cthroop Date 2020-11-25 Time 16:43 Rev Time 0.00
Received By cthroop Date 2020-11-25 Time 16:14 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2021-01-07 Cont ID  
Sent By awooten Date 2021-01-07 Time   Rev Time 0.00
Received By awooten Date 2021-01-07 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2020-12-08 Cont ID  
Sent By awooten Date 2020-12-08 Time   Rev Time  
Received By awooten Date 2020-12-08 Time   Sent To  
Notes
2020-12-08 14:23:37*****************************ZONING REVIEW
 FAILED***************************
  
 A SEPARATE DRIVEWAY PERMIT IS REQUIRED PRIOR TO
 APPROVAL.
  
 ALANA WOOTEN
 PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]