Plan Review Details - Permit 20110345
Plan Review Stops For Permit 20110345
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2020-12-21 Cont ID  
Sent By abelisle Date 2020-12-21 Time 07:12 Rev Time 0.00
Received By abelisle Date 2020-12-21 Time 06:29 Sent To I
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-11-23 Cont ID  
Sent By medwards Date 2020-11-23 Time 14:43 Rev Time 0.00
Received By medwards Date 2020-11-23 Time 13:43 Sent To  
Notes
2020-11-23 14:43:591ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20110345
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE THE LENGTH OF PIPE FROM WHERE YOU
 WILL ADD REGULATOR ON MAIN LINE TO THE 1 INCH CSST. FBC
 FG 402.4.1
  
 2) PLEASE PROVIDE PRESSURE OF REGULATOR YOU WILL ADD TO
 THE MAIN LINE. FBC FG 410.1
  
 3) LONGEST RUN IS NOT 35 FEET, TO FIND THE LONGEST
 DEVELOPED LENGTH FOR GAS LINE SIZING YOU AND EACH
 BRANCH FROM THE GAS METER TO THE MOST REMOTE APPLIANCE.
 PLEASE PROVIDE THE LONGEST DEVELOPED LENGTH DISTANCE
 FROM THE METER TO THE MOST REMOTE APPLIANCE. THE
 ORIGINAL PLAN (06060500) FOR THE GAS SYSTEM CALCULATES
 OUT TO BE 92 FEET FOR THE LONGEST DEVELOPED LENGTH.
 THAT SYSTEM WAS SIZED FOR THE MAX. BTU OF 195 BTU?S FBC
 FG 402.4.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-12-23 Cont ID  
Sent By jleahy Date 2020-12-23 Time 11:53 Rev Time 0.00
Received By jleahy Date 2020-12-04 Time 16:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-11-23 Cont ID  
Sent By medwards Date 2020-11-23 Time 14:45 Rev Time 0.00
Received By medwards Date 2020-11-13 Time 20:52 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2020-12-21 Cont ID  
Sent By abelisle Date 2020-12-21 Time 06:29 Rev Time 0.00
Received By abelisle Date 2020-12-21 Time 06:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-11-23 Cont ID  
Sent By medwards Date 2020-11-23 Time 14:45 Rev Time 0.00
Received By medwards Date 2020-11-23 Time 14:45 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-11-23 Cont ID  
Sent By medwards Date 2020-11-23 Time 14:45 Rev Time 0.00
Received By medwards Date 2020-11-23 Time 14:45 Sent To  
Notes
***NONE***