Plan Review Stops For Permit 20110342 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2020-12-17 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-12-17 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-12-17 |
Time |
10:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2021-03-23 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-03-23 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-03-23 |
Time |
09:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2021-03-05 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-03-05 |
Time |
08:29 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-03-04 |
Time |
15:23 |
Sent To |
|
|
Notes |
2021-03-05 08:29:12 | NEW SFR | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) STORAGE ROOM NEXT TO THE GARAGE SHOWS FLOOD VENTS - | | THE EXTERIOR GRADE APPEARS HIGH - PLEASE SHOW THE | | EXTERIOR GRADE TO COMPLY WITH FBC | | R322.2.2.1INSTALLATION OF OPENINGS. | | THE WALLS OF ENCLOSED AREAS SHALL HAVE OPENINGS | | INSTALLED SUCH THAT: THE BOTTOM OF EACH OPENING SHALL | | BE NOT MORE THAN 1 FOOT (305 MM) ABOVE THE HIGHER OF | | THE FINAL INTERIOR GRADE OR FLOOR AND THE FINISHED | | EXTERIOR GRADE IMMEDIATELY UNDER EACH OPENING. | | 2) THE STORAGE ROOM WALLS AND FLOORING BELOW BASE FLOOD | | ELEVATION NEED TO COMPLY WITH FBC R322.1.8 | | FLOOD-RESISTANT MATERIALS. | | BUILDING MATERIALS AND INSTALLATION METHODS USED FOR | | FLOORING AND INTERIOR AND EXTERIOR WALLS AND WALL | | COVERINGS BELOW THE ELEVATION REQUIRED IN SECTION | | R322.2 OR R322.3 SHALL BE FLOOD DAMAGE-RESISTANT | | MATERIALS THAT CONFORM TO THE PROVISIONS OF FEMA TB-2. | | 3) DRAWING C-1 HAS NOT BEEN REVISED - DRAWING "C1" | | SHOWS THE FFE AT 7.63 NAVD - PLEASE REVISE AS THE FLOOR | | PLANS WERE REVISED TO SHOW 8.13 NAVD | | 4) DRAWING C-1 - PLEASE SHOW ELEVATIONS USING NAVD - | | LEGEND ON DRAWING C-1 SHOWS ELEVATIONS USING NGVD BUT | | THE FLOOR ELEVATION IS SHOWN USING NAVD. | | ELEVATION CERTIFICATE = | | A8 PLEASE SHOW THE SQUARE FOOTAGE FOR THE STORAGE ROOM | | (ENCLOSED FLOOR). | | C2(A) PLEASE SHOW THE TOP OF ENCLOSURE FLOOR ELEVATION. | | C2(B) PLEASE SHOW THE TOP OF THE NEXT HIGHEST FLOOR | | (THE FIRST FLOOR OF THE HOUSE) | | C2(F) THE LOWEST ADJACENT GRADE IS ABOVE THE STORAGE | | ROOM AND GARAGE FLOOD VENTS? | | | | 5) ROOFING SYSTEM TO BE DEFERRED. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2021-02-04 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-02-04 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-02-04 |
Time |
13:45 |
Sent To |
|
|
Notes |
2021-02-04 15:37:02 | NEW SFR | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) ONLY ROOMS USED FOR "STORAGE", "PARKING", AND | | "BUILDING ACCESS" CAN HAVE THE FLOOR ELEVATION BELOW | | THE "LOWEST FLOOR" ELEVATION. THE ROOM MARKED | | "MECHANICAL ROOM" WILL NEED TO HAVE THE LOWEST FLOOR | | ELEVATION AT 8.00 NAVD - FLOOD ZONE IS SHOWN ON DRAWING | | A-003 AS AE 6 - THE BUILDING "LOWEST FLOOR" (FBC | | R322.1.5) WILL NEED TO BE 8.00 NAVD PER CITY ORDINANCE | | 4729-17 SEC. 18-33 (1). BUILDINGS AND STRUCTURES IN | | FLOOD HAZARD AREAS NOT DESIGNATED AS COASTAL A ZONES | | SHALL HAVE THE LOWEST FLOORS ELEVATED TO OR ABOVE THE | | BASE FLOOD ELEVATION PLUS TWO FEET OR THE DESIGN FLOOD | | ELEVATION, WHICHEVER IS HIGHER. (IF THE ROOM | | DESIGNATION IS CHANGED TO "STORAGE" IT CAN REMAIN AT | | THE PROPOSED FLOOR ELEVATION BUT WILL REQUIRE FLOOD | | VENTS - YOU WILL NEED TO SHOW THAT THE AC EQUIPMENT | | WILL BE ELEVATED TO THE REQUIRED ELEVATION FBC R322.1.6 | | - YOU MAY ALSO NEED TO REVISE THE ELEVATION CERTIFICATE | | IF YOU ADD MORE FLOOD VENTS) | | 2) PLEASE PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVAL FOR THE OVERHEAD GARAGE DOOR THAT IS | | LISTED BY PRODUCT APPROVAL NUMBER ON THE DRAWINGS. | | 3) PLEASE PROVIDE A COMPLETE MIAMI DADE OR FLORIDA | | STATE METAL ROOFING PRODUCT APPROVAL FOR THE METAL | | ROOFING PRODUCT APPROVAL LISTED ON THE DRAWINGS. | | 4) PRODUCT APPROVAL FOR THE FLAT DECK ROOFING = PLEASE | | CIRCLE THE ROOFING SYSTEM TO BE USED IN THE PRODUCT | | APPROVAL - IF NEEDED PLEASE PROVIDE SIGNED AND SEALED | | ADDITIONAL ATTACHMENT DETAILS FROM AN ARCHITECT OR | | ENGINEER FOR THE ROOF ZONES 2 AND 3 WHICH MAY REQUIRE A | | HIGHER WIND PRESSURE - SEE NOTES ON THE PRODUCT | | APPROVAL. | | 5) PRODUCT APPROVAL FOR THE MULL BAR (18-0205.05) HAS | | EXPIRED - PLEASE PROVIDE AN UPDATED MULL BAR PRODUCT | | APPROVAL. | | 6) DRAWING "C1" SHOWS THE FFE AT 7.63 NAVD - PLEASE | | REVISE AS THE FLOOR PLANS WERE REVISED TO SHOW 8.13 | | NAVD | | | | 7) ROOFING SYSTEM AND WINDOW AND DOOR PRODUCT APPROVALS | | MAY BE DEFERRED SUBMITTALS BY LISTING ITEMS TO BE | | DEFERRED ON THE CONSTRUCTION DOCUMENTS - 107.3.4.1 | | DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS SECTION, | | DEFERRED SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF | | THE DESIGN THAT ARE NOT SUBMITTED AT THE TIME OF THE | | APPLICATION AND THAT ARE TO BE SUBMITTED TO THE | | BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. DEFERRAL | | OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF | | THE BUILDING OFFICIAL. THE REGISTERED DESIGN | | PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE | | DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR | | REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED | | SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL | | REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL | | WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL | | DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL | | CONFORMANCE TO THE DESIGN OF THE BUILDING. THE DEFERRED | | SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE | | DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE | | BUILDING OFFICIAL. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-01-13 |
|
|
Cont ID |
|
Sent By |
mcphers |
Date |
2021-01-13 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-01-13 |
Time |
14:53 |
Sent To |
|
|
Notes |
2021-01-13 15:24:41 | NEW SFR | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) FLOOD ZONE IS SHOWN ON DRAWING A-003 AS AE 6 - THE | | BUILDING "LOWEST FLOOR" (FBC R322.1.5) WILL NEED TO BE | | 8.00 NAVD PER CITY ORDINANCE 4729-17 SEC. 18-33 (1). | | BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT | | DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST | | FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION | | PLUS TWO FEET OR THE DESIGN FLOOD ELEVATION, WHICHEVER | | IS HIGHER. | | 2) PLEASE PROVIDE A PROPOSED ELEVATION CERTIFICATE FOR | | BUILDINGS IN FLOOD ZONES (AE6) | | 3) PLEASE SHOW EQUIPMENT PAD ELEVATIONS TO MEET | | REQUIREMENTS FBC R322.1.6 | | 4) ADDING FLOOD VENTS TO A GARAGE OVERHEAD DOOR WILL | | VOID THE MIAMI DADE NOA FOR THE OVERHEAD DOOR. PLEASE | | PROVIDE A FIX. | | 5) PLEASE PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS AND DOORS. | | 6) PLEASE PROVIDE A COMPLETE MIAMI DADE OR FLORIDA | | STATE ROOFING PRODUCT APPROVALS. | | 7) ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED | | APPROVED BY THE DESIGNER OF RECORD OR LISTED ON THE | | DRAWINGS.(PLEASE CHECK THE LISTED PRODUCT APPROVAL | | NUMBERS ON THE DRAWINGS - I CANNOT FIND SOME OF THEM ON | | THE FLORIDA STATE PRODUCT APPROVAL WEB SITE). | | 8) ROOFING SYSTEM AND WINDOW AND DOOR PRODUCT APPROVALS | | MAY BE DEFERRED SUBMITTALS BY LISTING ITEMS TO BE | | DEFERRED ON THE CONSTRUCTION DOCUMENTS - 107.3.4.1 | | DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS SECTION, | | DEFERRED SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF | | THE DESIGN THAT ARE NOT SUBMITTED AT THE TIME OF THE | | APPLICATION AND THAT ARE TO BE SUBMITTED TO THE | | BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. DEFERRAL | | OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF | | THE BUILDING OFFICIAL. THE REGISTERED DESIGN | | PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE | | DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR | | REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED | | SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL | | REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL | | WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL | | DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL | | CONFORMANCE TO THE DESIGN OF THE BUILDING. THE DEFERRED | | SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE | | DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE | | BUILDING OFFICIAL. | | 9) A GUARD RAIL IS REQUIRED FOR THE 2ND FLOOR GUEST | | ROOM EXTERIOR DOOR FBC R312 | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-11-24 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-11-24 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-11-23 |
Time |
14:55 |
Sent To |
|
|
Notes |
2020-11-24 09:15:41 | NEW SFR | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) ON THE SITE PLAN OR ON A SURVEY WITH THE BUILDING | | PLACED SHOW THE SEPARATION LINE BETWEEN FLOOD ZONE AE6 | | AND X - NEEDED TO DETERMINE IF THE BUILDING IS IN THE | | AE6 ZONE - THE LOWEST FLOOR ELEVATION WILL NEED TO BE | | 8.00 NAVD (CITY ORD: 4729 17) | | 2) PLEASE SHOW THE DOOR FROM THE GARAGE TO THE LIVING | | SPACE TO COMPLY WITH FBC R302.5.1 | | 3) PLEASE SHOW EQUIPMENT PAD ELEVATIONS TO MEET | | REQUIREMENTS FBC R322.1.6 | | 4) PLEASE SHOW THE FLOOD VENTS IN THE GARAGE TO COMPLY | | WITH FBC R322.2.2 | | 5) PLEASE PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS AND DOORS. | | 6) PLEASE PROVIDE A COMPLETE MIAMI DADE OR FLORIDA | | STATE ROOFING PRODUCT APPROVALS. | | 7) ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED | | APPROVED BY THE DESIGNER OF RECORD OR LISTED ON THE | | DRAWINGS. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-12-04 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-12-04 |
Time |
12:11 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-12-04 |
Time |
12:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
Rev No |
1 |
Status |
P |
Date |
2021-12-08 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2021-12-08 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2021-12-08 |
Time |
15:16 |
Sent To |
|
|
Notes |
2021-12-08 15:15:59 | INSERTED LOW VOLTAGE STOP AS PER INSTRUCTIONS FROM S.H. | | 12/8/21 M.PETERSON |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2021-01-09 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2021-01-09 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2021-01-09 |
Time |
16:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2020-11-30 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-11-30 |
Time |
16:37 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-11-30 |
Time |
16:37 |
Sent To |
|
|
Notes |
2020-11-30 16:40:24 | GAS REVIEW | | 11/30/2020 | | | | 1) THE GAS PIPING LAYOUT AND RISER DRAWING SHOWN ON THE | | PLANS WERE NOT REVIEWED AT THIS TIME. PLEASE SUBMIT THE | | DRAWINGS UNDER A SEPARATE PERMIT AND INCLUDE | | MANUFACTURER'S SPECIFICATIONS FOR ALL GAS APPLIANCES | | AND EQUIPMENT. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2021-12-08 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2021-12-08 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2021-12-08 |
Time |
15:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2021-03-23 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-03-23 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-03-15 |
Time |
15:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-03-05 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-03-05 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-02-12 |
Time |
15:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-02-12 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-02-12 |
Time |
09:38 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-01-22 |
Time |
13:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-01-13 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-01-13 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-01-04 |
Time |
14:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-12-18 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-12-18 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-11-13 |
Time |
16:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-02-12 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-02-02 |
Time |
15:55 |
Sent To |
|
|
Notes |
2021-02-12 10:57:00 | 02/12/21 UPLOADED MU 2021 005140 - $22.46-PAID. CC | 2021-02-02 15:56:06 | 2/2/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2020-11-24 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-11-24 |
Time |
09:15 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-11-23 |
Time |
15:57 |
Sent To |
|
|
Notes |
2020-11-24 09:16:28 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2021-01-11 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-01-11 |
Time |
09:27 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-01-11 |
Time |
08:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-11-18 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-11-18 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-11-18 |
Time |
14:48 |
Sent To |
|
|
Notes |
2020-11-18 14:48:32 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT-20110342 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE PROVIDE THE ENERGY CALCULATIONS. FBC EC | | 101.5.1.1.2 | | | | 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | CALCULATIONS FOR ALL SYSTEMS. FBC RES M1401.3 | | | | 3) SHEET M1.1A- BECAUSE THE MECHANICAL ROOM IS | | CONDITIONED, VERIFY THAT THE MECHANICAL ROOM WHERE | | AHU-2 IS LOCATED IS SEPARATED FROM THE GARAGE. FBC | | R302.5.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
5 |
Status |
P |
Date |
2021-03-23 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-03-23 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-03-23 |
Time |
09:35 |
Sent To |
|
|
Notes |
2021-03-23 09:36:37 | AE 6 | | PROPOSED LOWEST FLOOR = 8.00 |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
4 |
Status |
F |
Date |
2021-03-05 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-03-05 |
Time |
08:30 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-03-05 |
Time |
08:30 |
Sent To |
|
|
Notes |
2021-03-05 08:30:23 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
3 |
Status |
F |
Date |
2021-02-04 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-02-04 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-02-04 |
Time |
15:38 |
Sent To |
|
|
Notes |
2021-02-04 15:39:20 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
2 |
Status |
F |
Date |
2021-01-13 |
|
|
Cont ID |
|
Sent By |
mcphers |
Date |
2021-01-13 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-01-13 |
Time |
15:37 |
Sent To |
|
|
Notes |
2021-01-13 15:38:11 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
1 |
Status |
F |
Date |
2020-11-24 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-11-24 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-11-24 |
Time |
09:16 |
Sent To |
|
|
Notes |
2020-11-24 09:17:23 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2021-01-09 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2021-01-09 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2021-01-09 |
Time |
15:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-11-30 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-11-30 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-11-30 |
Time |
10:44 |
Sent To |
|
|
Notes |
2020-11-30 16:06:45 | 1ST REVIEW FBC-2017 RES. | | PERMIT- 20110342 | | 11/30/2020 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE NOTE SEPARATE PERMITS ARE REQUIRED FOR THE | | GAS PIPING, WATER SERVICE BACKFLOW PREVENTER, POOL, AND | | IRRIGATION SYSTEM- SECTIONS 105.1 & 107.2.1 WPB. | | COMPLETE PLANS AND SPECIFICATIONS ARE REQUIRED. | | | | A) THE GAS PIPING LAYOUT AND RISER DRAWING SHOWN ON THE | | PLANS WERE NOT REVIEWED AT THIS TIME. PLEASE SUBMIT THE | | DRAWINGS UNDER A SEPARATE PERMIT AND INCLUDE | | MANUFACTURER'S SPECIFICATIONS FOR ALL GAS APPLIANCES | | AND EQUIPMENT. | | | | B) BACKFLOW PREVENTER: A FLORIDA LICENSED PLUMBING | | CONTRACTOR SHALL OBTAIN A SEPARATE PERMIT FOR | | INSTALLATION OF THE POTABLE WATER SERVICE BACKFLOW | | PREVENTER IN ACCORDANCE WITH SECTION 105.1 WPB AND | | SECTION 90-33 WPB CODE OF ORDINANCES. THE DEVICE SHALL | | BE TESTED AND CERTIFIED BY THE WPB UTILITIES DEPARTMENT | | PRIOR TO FINAL INSPECTION BY THE WPB BUILDING | | DEPARTMENT. PLEASE CONTACT THE WPB UTILITIES CENTRAL | | OPERATIONS DEPT. AT 561-822-2210 FOR FURTHER | | INFORMATION. | | | | 2) THE ENERGY FORM R405-2017 INDICATES THE TANKLESS | | WATER HEATER TO BE 50 GALLONS AND 0.97 EFFICIENCY. | | CORRECT THE GALLON SIZE DATA AND SUBMIT MANUFACTURER'S | | SPECIFICATIONS TO CONFIRM THE EFFICIENCY RATING- TABLE | | C404.1 FBC- EC. | | | | 3) SHEET PS.1.1: THE LOCATION OF THE 2-WAY CLEANOUT | | SHALL BE AT THE JUNCTION OF THE BUILDING DRAIN AND | | BUILDING SEWER OR WITHIN 10 FT. UPSTREAM OF THE | | JUNCTION. PLEASE NOTE THAT BUILDING DRAIN BY DEFINITION | | EXTENDS 30 INCHES BEYOND THE EXTERIOR WALL AT WHICH | | POINT IT TRANSITIONS INTO THE BUILDING SEWER- SECTIONS | | R202 & P3005.2.3 FBC RES. | | | | 4) SHEET P0.3 & P1.0B: CLEANOUTS AND ACCESS TO THE | | CLEANOUTS ARE REQUIRED WHERE THE VERTICAL RAIN WATER | | LEADERS CONNECT WITH THE HORIZONTAL UNDERSLAB STORM | | DRAINS- SEE SECTIONS 1101.8, 708.1.4, 708.1.10 FBC P | | AND P3005.2.4, AND P3005.2.10 FBC RES. | | | | 5) P1.1A: PROVIDE WATER HAMMER ARRESTORS FOR SUPPLY | | LINES TO THE DISHWASHER, ICE MAKER, AND WASHING | | MACHINE- SECTION P2903.5 FBC RES. | | | | 6) P1.1A: PROVIDE A BACKFLOW PREVENTER FOR THE SUPPLY | | LINE TO THE ICE MAKER- SECTION P2902.1 FBC RES. | | | | 7) P1.1A: INDICATE HOW THE SUPPLY LINES UNDER THE SLAB | | WILL BE PROTECTED FROM CORROSION- SECTION P2603.3 FBC | | RES. | | | | 8) A1-101.2 & A-102: PROVIDE THE DIMENSIONS OF THE | | SHOWERS- SECTION P2708.1 FBC RES. | | | | 9) P0.2: PROVIDE A SHOWER PAN DETAIL- SECTIONS P2709.1 | | & P2709.2 FBC RES. | | | | 10) P1.3: PLEASE NOTE UPON COMPLETION OF THE NEW STORM | | DRAINAGE SYSTEMS AS SHOWN ON THE PLAN A CERTIFICATION | | FROM A LICENSED PROFESSIONAL SHALL BE SUBMITTED TO THE | | INSPECTOR IN ORDER TO RECEIVE FINAL APPROVAL- SECTION | | 110.9 IMPACT OF CONSTRUCTION WPB. | | | | 11) P1.3: THE ROOF DRAINAGE SYSTEMS SHALL BE IN | | COMPLIANCE WITH SECTIONS R903.4.1 FBC RES AND 1101.2 | | FBC P: | | | | A) VERIFY THE ROOF IS DESIGNED FOR THE MAXIMUM POSSIBLE | | DEPTH OF WATER THAT WILL POND THEREON AS DETERMINED BY | | THE RELATIVE LEVELS OF ROOF DECK AND OVERFLOW WEIRS, | | SCUPPERS, EDGES OR SERVICEABLE DRAINS IN COMBINATION | | WITH THE DEFLECTED STRUCTURAL ELEMENTS. IN DETERMINING | | THE MAXIMUM POSSIBLE DEPTH OF WATER, ALL PRIMARY ROOF | | DRAINAGE MEANS SHALL BE ASSUMED TO BE BLOCKED- SECTION | | 1101.7 FBC P. | | | | B) PROVIDE THE ROOF DRAIN FLOW RATE BASED ON SECTION | | 1105.2, AND CALCULATIONS FOR SIZING THE PRIMARY | | VERTICAL CONDUCTORS AND LEADERS AND HORIZONTAL BRANCHES | | BASED ON SECTIONS 1106.1, FIGURE 1106.1 AND SECTION | | 1108.3. | | | | C) PROVIDE A PRIMARY ROOF DRAIN INSTALLATION DETAIL. | | SHOW THE MAKES AND MODELS OF THE PRIMARY ROOF DRAINS, | | AND SUBMIT PRODUCT SPECIFICATION SHEETS- SECTIONS | | 1102.6 AND 1108.1. | | | | D) PROVIDE AN OVERFLOW SCUPPER DETAIL PER SECTIONS | | R903.4.1 FBC RES. AND 1108.3 FBC P. | | | | E) SHOW THE LOCATIONS OF GUTTERS FOR THE SLOPED ROOFS | | AND PROVIDE VERTICAL LEADER AND HORIZONTAL GUTTER SIZES | | IN ACCORDANCE WITH TABLES 1106.3 AND 1106.6. | | | | 12) PROVIDE A PLUMBING SUB-PERMIT APPLICATION- SECTION | | 105.1 WPB. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
5 |
Status |
N |
Date |
2021-03-23 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-03-23 |
Time |
09:37 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-03-23 |
Time |
09:37 |
Sent To |
|
|
Notes |
2021-03-23 09:37:23 | DEFERRED |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
4 |
Status |
N |
Date |
2021-03-05 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-03-05 |
Time |
08:32 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-03-05 |
Time |
08:32 |
Sent To |
|
|
Notes |
2021-03-05 08:32:42 | ROOFING TO BE DEFERRED |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
F |
Date |
2021-02-04 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-02-04 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-02-04 |
Time |
15:39 |
Sent To |
|
|
Notes |
2021-02-04 15:40:01 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2021-01-13 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-01-13 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-01-13 |
Time |
15:37 |
Sent To |
|
|
Notes |
2021-01-13 15:37:45 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-11-24 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-11-24 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-11-23 |
Time |
15:57 |
Sent To |
|
|
Notes |
2020-11-24 09:18:20 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
P |
Date |
2021-03-23 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-03-23 |
Time |
09:36 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-03-23 |
Time |
09:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2021-03-05 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-03-05 |
Time |
08:32 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-03-05 |
Time |
08:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2021-02-04 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-02-04 |
Time |
15:43 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-02-04 |
Time |
15:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-01-13 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-01-13 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-01-13 |
Time |
15:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-11-19 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-11-18 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-11-18 |
Time |
15:22 |
Sent To |
|
|
Notes |
2020-11-19 07:16:46 | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2021-02-10 |
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2021-02-10 |
Time |
09:37 |
Rev Time |
0.00 |
Received By |
kalexand |
Date |
2021-02-10 |
Time |
09:37 |
Sent To |
I |
|
Notes |
2021-02-10 09:39:36 | SEE PREVIOUS COMMENT. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2020-12-17 |
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2020-12-17 |
Time |
17:13 |
Rev Time |
0.00 |
Received By |
kalexand |
Date |
2020-12-17 |
Time |
17:13 |
Sent To |
I |
|
Notes |
2020-12-17 17:23:17 | A SEPARATE LANDSCAPE PERMIT SHALL BE ISSUED. ALL | | LANDSCAPING SHALL BE INSTALLED AND PASS INSPECTION | | PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY / | | COMPLETION. |
|
|