Plan Review Details - Permit 20110243
Plan Review Stops For Permit 20110243
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-11-19 Cont ID  
Sent By rmcdouga Date 2020-11-19 Time 16:15 Rev Time 0.00
Received By rmcdouga Date 2020-11-19 Time 16:12 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-11-19 Cont ID  
Sent By rmcdouga Date 2020-11-19 Time 13:15 Rev Time 0.00
Received By rmcdouga Date 2020-11-19 Time 13:15 Sent To  
Notes
2020-11-19 13:28:10PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 THE FOLLOWING TEST REPORTS ARE REQUIRED:
  
 FBC 603.1 FLAME SPREAD - ASTM E 84-09
  
 FBC 1207.2 AIR-BORNE SOUND. ASTM E 90-04
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E 492-09
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 1) THE TEST REPORT FOR STRUCTURE-BORNE SOUND, ASTM E
 492-09, IS A BLANK PAGE. FBC1207.3
  
 2) THE REQUIRED FLAME SPREAD TEST REPORT FOR THE SOUND
 INSULATION, ASTM E 84-09, WAS NOT SUBMITTED. FBC 603.1
  
 3) THE TEST REPORTS WILL HAVE TO CLEARLY IDENTIFY THE
 PRODUCT THAT IS BEING TESTED IN ORDER TO VERIFY THAT IT
 IS THE PRODUCT THAT WILL BE INSTALLED. FBC 107.2.1
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-11-19 Cont ID  
Sent By rmcdouga Date 2020-11-19 Time 16:15 Rev Time 0.00
Received By rmcdouga Date 2020-11-19 Time 15:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-11-19 Cont ID  
Sent By rmcdouga Date 2020-11-19 Time 13:15 Rev Time 0.00
Received By rmcdouga Date 2020-11-10 Time 16:39 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-11-19 Cont ID  
Sent By rmcdouga Date 2020-11-19 Time 13:15 Rev Time 0.00
Received By rmcdouga Date 2020-11-19 Time 13:15 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved