Plan Review Stops For Permit 20110213 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-01-05 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-01-05 |
Time |
17:35 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2021-01-05 |
Time |
17:06 |
Sent To |
|
|
Notes |
2021-01-05 17:41:34 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW APPROVED WITH PROVISOS: | | | | THE ENGINEER HAS CLARIFIED THE DIMENSIONS (3/8"X6"X6") | | OF THE PLATES SHOWN ON DETAIL 3 OF PAGE C10. | | | | AWS D1.1 CLAUSE 5.2 & 6.7: AT TIME OF INSPECTION PLEASE | | PROVIDE A WELD PROCEDURE SPECIFICATION; THE W.P.S. | | SPECIFIES THE REQUIRED ESSENTIAL VARIABLES INCLUDING: | | BASE MATERIALS, JOINTS, PROCESS, AND FILLER METALS TO | | BE USED. | | AWS D1.1 CLAUSE 6.16: AT TIME OF INSPECTION PLEASE | | PROVIDE A WELDER PERFORMANCE QUALIFICATION RECORD; THE | | W.P.Q.R. PROVIDES INFORMATION WHICH CAN BE USED TO | | VERIFY THE WELDER?S QUALIFICATION AND CERTIFICATION AS | | IT RELATES TO THE WELDING REQUIREMENTS OF THE PROJECT. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-11-28 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-11-28 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-11-28 |
Time |
09:58 |
Sent To |
|
|
Notes |
2020-11-28 12:01:46 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW DENIED: | | | | FBC B 107.2.1, PLEASE PROVIDE MORE DETAIL/CLARIFY THE | | FOLLOWING: | | | | 1) PAGE C10, THE WELDED CONNECTIONS FOR THE MOUNT BRACE | | ARE NOT CLEAR AS DETAIL #3 IDENTIFIES A 3/8" THICK | | PLATE BY 6' LONG BY 6" WIDE IN TWO LOCATIONS ALONG THE | | BOTTOM OF CONNECTION AREAS. THE WELDS ARE IDENTIFIED AS | | 3/16" FILLET WELDS BOTH SIDES OF WHAT APPEARS TO BE | | VERTICAL PLATE TO PLATE CONNECTIONS. | | | | 2) PAGE C11, THE SERVICE PLATFORM EXTENSION (DETAILS 1 | | & 2) ARE NOT SPECIFIC IN THE NUMBER OF 1/4" THRU BOLTS, | | 1/2" SQUARE U-BOLTS, 3"X3"X1/4" HSS ANGLES, & 12"X1 | | 1/2" PERF-O-GRIP PLANKS. THESE ITEMS ALL HAVE ONLY A | | TYPICAL QUANTITY. PLEASE PROVIDE SPECIFIC QUANTITIES | | FOR EACH ITEM. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-01-11 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2021-01-11 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2021-01-11 |
Time |
11:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-12-03 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2020-12-03 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2020-12-03 |
Time |
08:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-02-13 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-02-13 |
Time |
08:27 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-02-02 |
Time |
11:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-01-22 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-01-22 |
Time |
13:45 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-01-04 |
Time |
10:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-12-03 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2020-12-03 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2020-11-16 |
Time |
16:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-01-05 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-01-05 |
Time |
17:34 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2021-01-05 |
Time |
17:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-11-28 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-11-28 |
Time |
12:02 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-11-28 |
Time |
09:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2021-02-12 |
|
|
Cont ID |
|
Sent By |
elevesqu |
Date |
2021-02-12 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
elevesqu |
Date |
2021-02-12 |
Time |
15:50 |
Sent To |
|
|
Notes |
2021-02-12 15:51:03 | APPROVED THROUGH MINOR AMENDMENT TO WCF 20-01 DATED | | JANUARY 29, 2021. | | CONDITIONS OF APPROVAL FROM ORIGINAL CITYSCAPE APPROVAL | | STILL APPLY AS FOLLOWS: | | | | 1. ALL ANTENNAS, MOUNTS, FEED LINES AND ASSOCIATED | | EQUIPMENT MOUNTED ON THE PENTHOUSE WALLS S | | HALL MATCH THE EXISTING BUILDING COLORS. ALSO, ALL | | CABINETS SHALL MATCH THE EXISTING BUILDING COLORS. | | | | 2. THERE SHALL BE NO VISIBLE SIGNAGE OR MARKINGS ON THE | | ANTENNAS AND ASSOCIATED EQUIPMENT. | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | 561 822 1426 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2021-01-07 |
|
|
Cont ID |
|
Sent By |
elevesqu |
Date |
2021-01-07 |
Time |
09:06 |
Rev Time |
0.00 |
Received By |
elevesqu |
Date |
2021-01-07 |
Time |
09:06 |
Sent To |
|
|
Notes |
2021-01-07 09:07:12 | REPEAT COMMENT: PLEASE SUBMIT WIRELESS COMMUNICATIONS | | APPLICATION FOR THE MODIFICATIONS SINCE LAST APPROVAL | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | 561 822 1426 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-12-01 |
|
|
Cont ID |
|
Sent By |
elevesqu |
Date |
2020-12-01 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
elevesqu |
Date |
2020-11-24 |
Time |
16:09 |
Sent To |
|
|
Notes |
2020-12-01 10:45:05 | PLEASE SUBMIT A WIRELESS COMMUNICATIONS FACILITY | | APPLICATION - TO BE PROCESSED PRIOR TO PERMIT REVIEW | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | 561 822 1426 | | [email protected] |
|
|