Plan Review Details - Permit 20110156
Plan Review Stops For Permit 20110156 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-12-21 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-12-21 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-12-21 |
Time |
16:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-11-17 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-17 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-17 |
Time |
13:11 |
Sent To |
|
|
Notes |
2020-11-17 13:49:47 | PLAN REVIEW GENERATOR / BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1) PROVIDE STRUCTURAL DETAIL OF GENERATOR PAD. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | 2) STRUCTURAL PAD DETAIL SHALL BE SIGNED BY DESIGNER. | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | 481, F.S. & 61G1. | | | | 3) ADJUST THE LOCATION OF THE GENERATOR ON THE SURVEY. | | GENERATOR SHALL BE LOCATED PER R303.5.1. | | R303.5.1 INTAKE OPENINGS. | | MECHANICAL AND GRAVITY OUTDOOR AIR INTAKE OPENINGS | | SHALL BE LOCATED NOT LESS THAN 10 FEET (3048 MM) FROM | | ANY HAZARDOUS OR NOXIOUS CONTAMINANT, SUCH AS VENTS, | | CHIMNEYS, PLUMBING VENTS, STREETS, ALLEYS, PARKING LOTS | | AND LOADING DOCKS. | | | | PROVIDE SETBACK DIMENSIONS TO PROPERTY LINES, BUILDING | | AND BUILDING OPENINGS PER PER 107.2 CONSTRUCTION | | DOCUMENTS. | | | | 4) PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | (SFHA). TOP OF GENERATOR PAD SHALL BE AT OR ABOVE 8.0 | | FEET NAVD. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-12-23 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2020-12-23 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2020-12-23 |
Time |
09:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-11-20 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2020-11-20 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2020-11-20 |
Time |
15:34 |
Sent To |
|
|
Notes |
2020-11-20 15:42:18 | CODES IN EFFECT | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | REVIEW STATUS: FAILED. | | | | 1) PLEASE PROVIDE SPECS FOR TRANSFER SWITCH AND SHOW ON | | RISER DIAGRAM. TRANSFER SWITCH MUST BE LISTED FOR | | EMERGENCY POWER SYSTEM USE. PLEASE CONFIRM THAT THERE | | IS A SERVICE RATED DISCONNECT AHEAD OF TRANSFER SWITCH. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. | | | | SINCERELY, | | | | ENRIQUE QUINONEZ | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-12-23 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2020-12-23 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2020-12-18 |
Time |
15:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-11-20 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2020-11-20 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2020-11-05 |
Time |
08:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-12-21 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-12-21 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-12-21 |
Time |
16:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-11-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-20 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-20 |
Time |
14:56 |
Sent To |
|
|
Notes |
2020-11-20 15:00:19 | PLAN REVIEW / SIGNATURES | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | NO SIGNATURE REVIEW PERFORMED AT THIS TIME. SUBMIT | | STRUCTURAL PAD DESIGN PER BLDG REVIEW COMMENTS. | | | | FOR ENGINEERED PRE-CAST PAD | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | SIGNATURE. | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | WET SEAL AND SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 | | | | FOR CONTRACTOR DESIGNED SLAB ON GRADE | | | | | | 1. THE CONTRACTOR OR DESIGNER OF RECORD SHALL PROVIDE | | THEIR PRINTED NAME AND SIGNATURE ON PLAN SHEETS UNDER | | THEIR AUTHORITY ? | | 2017 WPB AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1, SECTION 107.2.1. | | | | 2. EITHER UPLOAD DOCUMENTS VIA THE PROJECTDOX PORTAL | | WITH SIGNATURE OF DESIGNER AS APPLICABLE; USE THE | | REQUIRED NAMING CONVENTION FOR EACH DOCUMENT OR DROP | | OFF (OR MAIL) ONE PAPER ORIGINAL WITH CONTRACTORS | | SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 | | | | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | 481, F.S. & 61G1. | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2020-12-21 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2020-12-21 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2020-12-21 |
Time |
10:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-12-10 |
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2020-12-10 |
Time |
11:53 |
Rev Time |
0.00 |
Received By |
kalexand |
Date |
2020-12-10 |
Time |
11:53 |
Sent To |
I |
|
Notes |
2020-12-10 11:59:00 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. GENERATOR EQUIPMENT ENCROACHES TOO FAR INTO REQUIRED | | SETBACK. PURSUANT TO THE CITY OF WEST PALM BEACH ZONING | | AND LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION | | 94-305(B)(4): MECHANICAL EQUIPMENT MAY NOT PROJECT MORE | | THAN 4 FEET INTO A REQUIRED SETBACK. | | | | 2. INDICATE SETBACKS FROM ALL ADJACENT PROPOERTY LINES. | | | | PURSUANT TO ZLDR SEC. 94-82 THE SETBACKS FOR THIS | | PROPERTY ARE AS FOLLOWS: | | REAR: 15 FEET, OR 10 PERCENT OF THE LOT DEPTH, | | WHICHEVER IS LESS. | | SIDE MINIMUM (ONE SIDE ONLY): | | --FOR LOTS UP TO 9,999 SQUARE FEET: 5 FEET; | | --FOR LOTS 10,000 SQUARE FEET AND OVER: 10 FEET. | | SIDE MINIMUM CUMULATIVE (BOTH SIDES): | | --FOR LOTS UP TO 7,499 SQUARE FEET: 15 FEET; | | --FOR LOTS 7,500 TO 9,999 SQUARE FEET: 20 FEET; | | --FOR LOTS 10,000 SQUARE FEET AND OVER: 25 FEET. | | | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | LIKE TO RESUBMIT ELECTRONICALLY, EMAIL | | [email protected] AND REQUEST TO HAVE YOUR | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG | | IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | ARE FINISHED UPLOADING. | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1442 | | TTY: 800.955.8771 | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
|