Plan Review Details - Permit 20110018
Plan Review Stops For Permit 20110018
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-01-15 Cont ID  
Sent By cthroop Date 2021-01-15 Time 11:12 Rev Time 0.00
Received By cthroop Date 2021-01-15 Time 09:22 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-11-14 Cont ID  
Sent By cthroop Date 2020-11-14 Time 11:43 Rev Time 0.00
Received By cthroop Date 2020-11-14 Time 10:47 Sent To  
Notes
2020-11-14 11:57:30PLAN REVIEW / BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC 2014
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 RE: HOUSE WAS GUTTED AND RE-BUILT W/O INSPECTIONS
  
 NOTICE: ACCESS TO COVERED ELEMENTS MAY BE REQUIRED AT
 CITY INSPECTORS DESCRETION.
  
 1. SUBMITTAL CONSIST OF AN ELECTRICAL FLOOR PLAN ONLY.
 107.2 CONSTRUCTION DOCUMENTS.
  
 2. STATE ON PLAN THE WALL AND CEILING INSULATION R
 VALUE.
 R402.1.1 INSULATION AND FENESTRATION CRITERIA.
 THE BUILDING THERMAL ENVELOPE SHALL MEET THE
 REQUIREMENTS OF TABLE R402.1.1 BASED ON THE CLIMATE
 ZONE SPECIFIED IN CHAPTER 3.
  
 3. IF SLAB WAS CUT FOR THE INSTALLATION OF THE NEW
 KITCHEN ISLAND, PROVIDE A SLAB REPAIR DETAIL.
 107.2 CONSTRUCTION DOCUMENTS.
  
 4. IF INT. WALLS WERE CONSTRUCTED FOR THE NEW HALF
 BATH, PROVIDE FRAMING DETAILS.
 107.2 CONSTRUCTION DOCUMENTS.
  
 NOTICE:
 REVIEWING THE PLANS/SPECIFICATIONS FOR CODE COMPLIANCE
 DOES NOT RELIEVE THE OWNER, DESIGN PROFESSIONAL,
 CONTRACTOR OR THEIR REPRESENTATIVES FROM THE
 RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY
 CHANGES/ALTERATIONS TO THE APPROVED PLANS SHALL BE
 APPROVED BY THIS DEPARTMENT TO AVOID VOIDING OF THE
 PERMIT.
  
 ALL WORK SHALL COMPLY WITH THE CODES AND IS SUBJECT TO
 THE FIELD INSPECTOR?S APPROVAL.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-01-15 Cont ID  
Sent By jleahy Date 2021-01-15 Time 08:47 Rev Time 0.00
Received By jleahy Date 2021-01-15 Time 07:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-11-13 Cont ID  
Sent By jleahy Date 2020-11-13 Time 03:35 Rev Time 0.00
Received By jleahy Date 2020-11-13 Time 03:33 Sent To  
Notes
2020-11-13 03:55:37ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) NO SMOKE/CARBON MONOXIDE ALARMS SHOWN
  
 PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED PER
 CODE. SHOW ON PLAN ALL EXISTING ALARMS. IF NONE ARE
 EXISTING OR NOT TO CODE, SHOW AS NEW INSTALLATIONS. FBC
 R314.3, FBC 107.2.1
  
 2) ALL OUTLETS IN THE GARAGE 120V SHALL BE GFCI
 PROTECTED.
 E3902.2 GARAGE AND ACCESSORY BUILDING RECEPTACLES.
 125-VOLT, SINGLE-PHASE, 15- OR 20-AMPERE RECEPTACLES
 INSTALLED IN GARAGES AND GRADE-LEVEL PORTIONS OF
 UNFINISHED ACCESSORY BUILDINGS USED FOR STORAGE OR WORK
 AREAS SHALL HAVE GROUND-FAULT CIRCUIT-INTERRUPTER
 PROTECTION FOR PERSONNEL. [210.8(A)(2)]
  
 3) OUTLETS NEEDED AT FRONT AND REAR OF RESIDENCE.
 FOR A ONE FAMILY DWELLING AND EACH UNIT OF A TWO-FAMILY
 DWELLING THAT IS AT GRADE LEVEL, AT LEAST ONE
 RECEPTACLE OUTLET READILY ACCESSIBLE FROM GRADE AND NOT
 MORE THAN 2.0 M (6.5 FT) ABOVE GRADE LEVEL SHALL BE
 INSTALLED AT THE FRONT AND BACK OF THE DWELLING. NEC
 210.52(E)(1) FBC RE3901.7
  
 4) OUTLETS FOR THE LAUNDRY AREA TO BE AFCI AND GFCI
 ALL 120-VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH
 CIRCUITS SUPPLYING OUTLETS IN DWELLING UNIT KITCHENS,
 LAUNDRY ROOMS, FAMILY ROOMS, DINING ROOMS, LIVING
 ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS,
 RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR AREAS
 OR ROOMS, SHALL HAVE AFCI PROTECTION. NEC 210.12; FBC
 RE3902.16
  
 5) ISLAND NEEDS ANOTHER OUTLET ON DISHWASHER END FOR
 COUNTER SPACE RECEPTACLES.
 COUNTERTOP SPACES SEPARATED BY RANGETOPS,
 REFRIGERATORS, OR SINKS SHALL BE CONSIDERED AS SEPARATE
 COUNTERTOP SPACES IN APPLYING THE REQUIREMENTS OF
 210.52(C)(1). IF A RANGE, COUNTER-MOUNTED COOKING UNIT,
 OR SINK IS INSTALLED IN AN ISLAND OR PENINSULAR
 COUNTERTOP AND THE DEPTH OF THE COUNTERTOP BEHIND THE
 RANGE, COUNTER-MOUNTED COOKING UNIT, OR SINK IS LESS
 THAN 300 MM (12 IN.), THE RANGE, COUNTER-MOUNTED
 COOKING UNIT, OR SINK SHALL BE CONSIDERED TO DIVIDE THE
 COUNTERTOP SPACE INTO TWO SEPARATE COUNTERTOP SPACES.
 EACH SEPARATE COUNTERTOP SPACE SHALL COMPLY WITH THE
 APPLICABLE REQUIREMENTS IN 210.52(C).
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status N Date 2020-11-24 Cont ID  
Sent By fmittner Date 2020-11-24 Time 11:53 Rev Time 0.00
Received By fmittner Date 2020-11-24 Time 11:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-01-15 Cont ID  
Sent By cthroop Date 2021-01-15 Time 11:12 Rev Time 0.00
Received By cthroop Date 2021-01-13 Time 12:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-12-03 Cont ID  
Sent By jleahy Date 2020-12-03 Time 12:55 Rev Time 0.00
Received By jleahy Date 2020-11-10 Time 13:52 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-01-15 Cont ID  
Sent By medwards Date 2021-01-15 Time 06:36 Rev Time 0.00
Received By medwards Date 2021-01-15 Time 06:24 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-11-12 Cont ID  
Sent By medwards Date 2020-11-12 Time 15:30 Rev Time 0.00
Received By medwards Date 2020-11-12 Time 15:17 Sent To  
Notes
2020-11-12 15:31:081ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20110018
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE PERMIT APPLICATION STATES THAT EVERYTHING WAS
 GUTTED INSIDE THEN EVERYTHING WAS PUT BACK THE SAME.
 PLEASE PROVIDE THE SCOPE OF WORK FOR THE MECHANICAL
 SYSTEMS. WAS THE HVAC SYSTEM REPLACED? IF SO PLEASE
 PROVIDE THE A/C LIKE FOR LIKE CHANGE OUT FORM. FBC
 107.2
  
 2) PLEASE PROVIDE A MECHANICAL DRAWING INDICATING THE
 NEW HVAC SYSTEM, THE DRYER DUCT INCLUDING LENGTH AND
 TERMINATION LOCATION. PROVIDE ON THE MECHANICAL DRAWING
 THE BATH EXHAUST FANS AND THE VENTING TERMINATION
 LOCATIONS. FBC 107.2
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-01-15 Cont ID  
Sent By lcrespo Date 2021-01-15 Time 09:36 Rev Time 0.00
Received By lcrespo Date 2021-01-15 Time 08:38 Sent To  
Notes
2021-01-15 09:37:4101/15/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-11-12 Cont ID  
Sent By lcrespo Date 2020-11-12 Time 16:23 Rev Time 0.00
Received By lcrespo Date 2020-11-12 Time 15:40 Sent To  
Notes
2020-11-12 16:25:3711/12/20 2ND PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. THE PLANS SUBMITTED A STATE THAT THERE IS AN
 EXISTING FIXTURES IN THE GARAGE I.E. LAV, WATER CLOSET
 AND SHOWER BUT THE CITY OF WEST PALM BEACH DOES NOT
 HAVE ANY RECORD OF PERMIT OR INSPECTIONS ON THESE ITEMS
 IN GARAGE AREA.
  
 2. SHOWER IS NOT SHOWN ON THE ISOMETRIC AND NO
 DIMENSIONS OF THE SHOWER ARE SHOWN PLEASE PROVIDE PER
 THE 2017 FBC SEC. R2708.1 GENERAL.
  
 3. THERE IS A WASHING MACHINE SHOWN WHERE LAV IS
 SUPPOSE TO BE. IS THIS A LAUNDRY SINK TYPE SETUP,
 PLEASE CLARIFY IN SOME TYPE OF NARRATIVE AS FAR AS THE
 SCOPE OF WORK TO BE DONE PER THE WPB AMENDMENTS TO THE
 FBC SEC 101.2 SCOPE.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-01-15 Cont ID  
Sent By medwards Date 2021-01-15 Time 06:38 Rev Time 0.00
Received By medwards Date 2021-01-15 Time 06:38 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-11-12 Cont ID  
Sent By medwards Date 2020-11-12 Time 15:32 Rev Time 0.00
Received By medwards Date 2020-11-12 Time 15:32 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-11-24 Cont ID  
Sent By fmittner Date 2020-11-24 Time 11:54 Rev Time 0.00
Received By fmittner Date 2020-11-24 Time 11:54 Sent To  
Notes
***NONE***