Plan Review Details - Permit 20110018
Plan Review Stops For Permit 20110018 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-01-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-01-15 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-01-15 |
Time |
09:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-11-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-14 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-14 |
Time |
10:47 |
Sent To |
|
|
Notes |
2020-11-14 11:57:30 | PLAN REVIEW / BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NEC 2014 | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | RE: HOUSE WAS GUTTED AND RE-BUILT W/O INSPECTIONS | | | | NOTICE: ACCESS TO COVERED ELEMENTS MAY BE REQUIRED AT | | CITY INSPECTORS DESCRETION. | | | | 1. SUBMITTAL CONSIST OF AN ELECTRICAL FLOOR PLAN ONLY. | | 107.2 CONSTRUCTION DOCUMENTS. | | | | 2. STATE ON PLAN THE WALL AND CEILING INSULATION R | | VALUE. | | R402.1.1 INSULATION AND FENESTRATION CRITERIA. | | THE BUILDING THERMAL ENVELOPE SHALL MEET THE | | REQUIREMENTS OF TABLE R402.1.1 BASED ON THE CLIMATE | | ZONE SPECIFIED IN CHAPTER 3. | | | | 3. IF SLAB WAS CUT FOR THE INSTALLATION OF THE NEW | | KITCHEN ISLAND, PROVIDE A SLAB REPAIR DETAIL. | | 107.2 CONSTRUCTION DOCUMENTS. | | | | 4. IF INT. WALLS WERE CONSTRUCTED FOR THE NEW HALF | | BATH, PROVIDE FRAMING DETAILS. | | 107.2 CONSTRUCTION DOCUMENTS. | | | | NOTICE: | | REVIEWING THE PLANS/SPECIFICATIONS FOR CODE COMPLIANCE | | DOES NOT RELIEVE THE OWNER, DESIGN PROFESSIONAL, | | CONTRACTOR OR THEIR REPRESENTATIVES FROM THE | | RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY | | CHANGES/ALTERATIONS TO THE APPROVED PLANS SHALL BE | | APPROVED BY THIS DEPARTMENT TO AVOID VOIDING OF THE | | PERMIT. | | | | ALL WORK SHALL COMPLY WITH THE CODES AND IS SUBJECT TO | | THE FIELD INSPECTOR?S APPROVAL. | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-01-15 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-01-15 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-01-15 |
Time |
07:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-11-13 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-11-13 |
Time |
03:35 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-11-13 |
Time |
03:33 |
Sent To |
|
|
Notes |
2020-11-13 03:55:37 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | 1) NO SMOKE/CARBON MONOXIDE ALARMS SHOWN | | | | PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED PER | | CODE. SHOW ON PLAN ALL EXISTING ALARMS. IF NONE ARE | | EXISTING OR NOT TO CODE, SHOW AS NEW INSTALLATIONS. FBC | | R314.3, FBC 107.2.1 | | | | 2) ALL OUTLETS IN THE GARAGE 120V SHALL BE GFCI | | PROTECTED. | | E3902.2 GARAGE AND ACCESSORY BUILDING RECEPTACLES. | | 125-VOLT, SINGLE-PHASE, 15- OR 20-AMPERE RECEPTACLES | | INSTALLED IN GARAGES AND GRADE-LEVEL PORTIONS OF | | UNFINISHED ACCESSORY BUILDINGS USED FOR STORAGE OR WORK | | AREAS SHALL HAVE GROUND-FAULT CIRCUIT-INTERRUPTER | | PROTECTION FOR PERSONNEL. [210.8(A)(2)] | | | | 3) OUTLETS NEEDED AT FRONT AND REAR OF RESIDENCE. | | FOR A ONE FAMILY DWELLING AND EACH UNIT OF A TWO-FAMILY | | DWELLING THAT IS AT GRADE LEVEL, AT LEAST ONE | | RECEPTACLE OUTLET READILY ACCESSIBLE FROM GRADE AND NOT | | MORE THAN 2.0 M (6.5 FT) ABOVE GRADE LEVEL SHALL BE | | INSTALLED AT THE FRONT AND BACK OF THE DWELLING. NEC | | 210.52(E)(1) FBC RE3901.7 | | | | 4) OUTLETS FOR THE LAUNDRY AREA TO BE AFCI AND GFCI | | ALL 120-VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH | | CIRCUITS SUPPLYING OUTLETS IN DWELLING UNIT KITCHENS, | | LAUNDRY ROOMS, FAMILY ROOMS, DINING ROOMS, LIVING | | ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, | | RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR AREAS | | OR ROOMS, SHALL HAVE AFCI PROTECTION. NEC 210.12; FBC | | RE3902.16 | | | | 5) ISLAND NEEDS ANOTHER OUTLET ON DISHWASHER END FOR | | COUNTER SPACE RECEPTACLES. | | COUNTERTOP SPACES SEPARATED BY RANGETOPS, | | REFRIGERATORS, OR SINKS SHALL BE CONSIDERED AS SEPARATE | | COUNTERTOP SPACES IN APPLYING THE REQUIREMENTS OF | | 210.52(C)(1). IF A RANGE, COUNTER-MOUNTED COOKING UNIT, | | OR SINK IS INSTALLED IN AN ISLAND OR PENINSULAR | | COUNTERTOP AND THE DEPTH OF THE COUNTERTOP BEHIND THE | | RANGE, COUNTER-MOUNTED COOKING UNIT, OR SINK IS LESS | | THAN 300 MM (12 IN.), THE RANGE, COUNTER-MOUNTED | | COOKING UNIT, OR SINK SHALL BE CONSIDERED TO DIVIDE THE | | COUNTERTOP SPACE INTO TWO SEPARATE COUNTERTOP SPACES. | | EACH SEPARATE COUNTERTOP SPACE SHALL COMPLY WITH THE | | APPLICABLE REQUIREMENTS IN 210.52(C). | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
N |
Date |
2020-11-24 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2020-11-24 |
Time |
11:53 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2020-11-24 |
Time |
11:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-01-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-01-15 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-01-13 |
Time |
12:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-12-03 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-12-03 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-11-10 |
Time |
13:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2021-01-15 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-01-15 |
Time |
06:36 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-01-15 |
Time |
06:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-11-12 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-11-12 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-11-12 |
Time |
15:17 |
Sent To |
|
|
Notes |
2020-11-12 15:31:08 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT-20110018 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE PERMIT APPLICATION STATES THAT EVERYTHING WAS | | GUTTED INSIDE THEN EVERYTHING WAS PUT BACK THE SAME. | | PLEASE PROVIDE THE SCOPE OF WORK FOR THE MECHANICAL | | SYSTEMS. WAS THE HVAC SYSTEM REPLACED? IF SO PLEASE | | PROVIDE THE A/C LIKE FOR LIKE CHANGE OUT FORM. FBC | | 107.2 | | | | 2) PLEASE PROVIDE A MECHANICAL DRAWING INDICATING THE | | NEW HVAC SYSTEM, THE DRYER DUCT INCLUDING LENGTH AND | | TERMINATION LOCATION. PROVIDE ON THE MECHANICAL DRAWING | | THE BATH EXHAUST FANS AND THE VENTING TERMINATION | | LOCATIONS. FBC 107.2 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2021-01-15 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-01-15 |
Time |
09:36 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-01-15 |
Time |
08:38 |
Sent To |
|
|
Notes |
2021-01-15 09:37:41 | 01/15/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-11-12 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-11-12 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-11-12 |
Time |
15:40 |
Sent To |
|
|
Notes |
2020-11-12 16:25:37 | 11/12/20 2ND PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | 1. THE PLANS SUBMITTED A STATE THAT THERE IS AN | | EXISTING FIXTURES IN THE GARAGE I.E. LAV, WATER CLOSET | | AND SHOWER BUT THE CITY OF WEST PALM BEACH DOES NOT | | HAVE ANY RECORD OF PERMIT OR INSPECTIONS ON THESE ITEMS | | IN GARAGE AREA. | | | | 2. SHOWER IS NOT SHOWN ON THE ISOMETRIC AND NO | | DIMENSIONS OF THE SHOWER ARE SHOWN PLEASE PROVIDE PER | | THE 2017 FBC SEC. R2708.1 GENERAL. | | | | 3. THERE IS A WASHING MACHINE SHOWN WHERE LAV IS | | SUPPOSE TO BE. IS THIS A LAUNDRY SINK TYPE SETUP, | | PLEASE CLARIFY IN SOME TYPE OF NARRATIVE AS FAR AS THE | | SCOPE OF WORK TO BE DONE PER THE WPB AMENDMENTS TO THE | | FBC SEC 101.2 SCOPE. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-01-15 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-01-15 |
Time |
06:38 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-01-15 |
Time |
06:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-11-12 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-11-12 |
Time |
15:32 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-11-12 |
Time |
15:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2020-11-24 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2020-11-24 |
Time |
11:54 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2020-11-24 |
Time |
11:54 |
Sent To |
|
|
Notes |
|
|
|