Plan Review Details - Permit 20101437
Plan Review Stops For Permit 20101437
Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-12-03 Cont ID  
Sent By medwards Date 2020-12-03 Time 13:31 Rev Time 0.00
Received By medwards Date 2020-11-30 Time 12:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-11-25 Cont ID  
Sent By medwards Date 2020-11-25 Time 07:17 Rev Time 0.00
Received By medwards Date 2020-11-24 Time 15:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-11-04 Cont ID  
Sent By medwards Date 2020-11-04 Time 07:31 Rev Time 0.00
Received By medwards Date 2020-11-03 Time 09:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2020-12-03 Cont ID  
Sent By medwards Date 2020-12-03 Time 13:31 Rev Time 0.00
Received By medwards Date 2020-12-03 Time 13:31 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-11-25 Cont ID  
Sent By medwards Date 2020-11-25 Time 07:16 Rev Time 0.00
Received By medwards Date 2020-11-25 Time 07:16 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-11-25 Cont ID  
Sent By medwards Date 2020-11-04 Time 07:27 Rev Time 0.00
Received By medwards Date 2020-11-04 Time 06:59 Sent To  
Notes
2020-11-04 07:27:261ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20101437
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE MORE DETAIL FOR THE SCOPE OF WORK. IS
 THIS A LIKE FOR LIKE CHANGE OUT FOR EACH HVAC SYSTEM?
 IF SO PLEASE SUBMIT A LIKE FOR LIKE CHANGE OUT FORM FOR
 EACH SYSTEM. IF THIS IS NOT A LIKE FOR LIKE CHANGE OUT
 FOR EACH SYSTEM BUT IS AN UPGRADE, THEN PLEASE SUBMIT
 THE ENERGY CALCULATIONS AND THE EQUIPMENT SIZING
 CALCULATIONS. FBC 107.2; FBC EC 101.5.1.1.2; FBC EC
 R403.7; FBC RES M1401.3
  
 2) PLEASE PROVIDE DETAILS OF THE CONDENSING UNITS TIE
 DOWN. FBC RES M1307.2
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-12-03 Cont ID  
Sent By medwards Date 2020-12-03 Time 13:31 Rev Time 0.00
Received By medwards Date 2020-12-03 Time 13:31 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-11-25 Cont ID  
Sent By medwards Date 2020-11-25 Time 07:14 Rev Time 0.00
Received By medwards Date 2020-11-25 Time 07:13 Sent To  
Notes
2020-11-25 07:16:04FARINO CALCULATIONS MUST BE DIGITALLY SIGNED AND SEALED
 AND THIRD PARTY VERIFIED. IT APPEARS THE SIGNATURE AND
 SEAL IS A COPY.
  
 PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-11-04 Cont ID  
Sent By medwards Date 2020-11-04 Time 07:29 Rev Time 0.00
Received By medwards Date 2020-11-04 Time 07:29 Sent To  
Notes
2020-11-04 07:31:15ENGINEER CAN NOT SELF CERTIFY, HE MUST USE A THIRD
 PARTY TO VERIFY HIS DIGITAL SIGNATURE AND SEAL.
  
 PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  