Plan Review Details - Permit 20101413
Plan Review Stops For Permit 20101413
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-05-26 Cont ID  
Sent By rmcphers Date 2021-05-26 Time 08:58 Rev Time 0.00
Received By rmcphers Date 2021-05-26 Time 08:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-02-05 Cont ID  
Sent By rmcphers Date 2021-02-05 Time 10:12 Rev Time 0.00
Received By rmcphers Date 2021-02-05 Time 09:36 Sent To  
Notes
2021-02-05 10:09:08SFR ADDITION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) FOR AIR-PERMEABLE RAFTER SPACE INSULATION - PLEASE
 SHOW THE RIGID BOARD OR SHEET INSULATION ON TOP OF THE
 ROOF SHEATHING TO COMPLY WITH FBC R806.5 UNVENTED ATTIC
 AND UNVENTED ENCLOSED RAFTER ASSEMBLIES. UNVENTED
 ATTICS AND UNVENTED ENCLOSED ROOF FRAMING ASSEMBLIES
 CREATED BY CEILINGS THAT ARE APPLIED DIRECTLY TO THE
 UNDERSIDE OF THE ROOF FRAMING MEMBERS AND STRUCTURAL
 ROOF SHEATHING APPLIED DIRECTLY TO THE TOP OF THE ROOF
 FRAMING MEMBERS/RAFTERS, SHALL BE PERMITTED WHERE ALL
 THE FOLLOWING CONDITIONS ARE MET:
  
 5.INSULATION SHALL BE LOCATED IN ACCORDANCE WITH THE
 FOLLOWING:
  
 5.1.ITEM 5.1.1, 5.1.2, 5.1.3 OR 5.1.4 SHALL BE MET,
 DEPENDING ON THE AIR PERMEABILITY OF THE INSULATION
 DIRECTLY UNDER THE STRUCTURAL ROOF SHEATHING.
  
 5.1.1.WHERE ONLY AIR-IMPERMEABLE INSULATION IS
 PROVIDED, IT SHALL BE APPLIED IN DIRECT CONTACT WITH
 THE UNDERSIDE OF THE STRUCTURAL ROOF SHEATHING.
  
 5.1.2.WHERE AIR-PERMEABLE INSULATION IS PROVIDED INSIDE
 THE BUILDING THERMAL ENVELOPE, IT SHALL BE INSTALLED IN
 ACCORDANCE WITH SECTION 5.1.1. IN ADDITION TO THE
 AIR-PERMEABLE INSULATION INSTALLED DIRECTLY BELOW THE
 STRUCTURAL SHEATHING, RIGID BOARD OR SHEET INSULATION
 SHALL BE INSTALLED DIRECTLY ABOVE THE STRUCTURAL ROOF
 SHEATHING IN ACCORDANCE WITH THE R-VALUES IN TABLE
 R806.5 FOR CONDENSATION CONTROL.
  
  
 2) PLEASE PROVIDE A COMPLETE MIAMI DADE OR FLORIDA
 STATE PRODUCT APPROVAL FOR THE ROOFING TILE - PLEASE
 CIRCLE THE TILE ATTACHMENT TO BE USED IN THE PRODUCT
 APPROVAL - IF USING ADHESIVE PLEASE PROVIDE THE PRODUCT
 APPROVAL FOR THE ADHESIVE.
  
 3) THE POOL CABANA WILL NEED A SEPARATE PERMIT - WHICH
 WILL ALLOW FOR SEPARATE BUILDING INSPECTIONS FOR EACH
 BUILDING.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-11-16 Cont ID  
Sent By rmcphers Date 2020-11-16 Time 11:25 Rev Time 0.00
Received By rmcphers Date 2020-11-16 Time 10:06 Sent To  
Notes
2020-11-16 11:25:45SFR ADDITION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW THE SMOKE DETECTOR LOCATIONS PER FBC
 R314.2.2 ALTERATIONS, REPAIRS AND ADDITIONS.
 WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS.
 2) PLEASE SHOW THE VENTILATION FOR THE RAFTER SPACES
 PER FBC R806.1 VENTILATION REQUIRED.
 ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE
 CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF
 RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE
 SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE
 ENTRANCE OF RAIN OR SNOW.
 3) PLEASE SHOW THE ROOF SLOPE AT THE TILE ROOF AREA FBC
 R905.3.2
 4) PLEASE PROVIDE A COMPLETE MIAMI DADE OR FLORIDA
 STATE PRODUCT APPROVAL FOR THE ROOFING TILE - PLEASE
 CIRCLE THE TILE ATTACHMENT TO BE USED IN THE PRODUCT
 APPROVAL - IF USING ADHESIVE PLEASE PROVIDE THE PRODUCT
 APPROVAL FOR THE ADHESIVE.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-01-29 Cont ID  
Sent By equinone Date 2021-01-29 Time 12:54 Rev Time 0.00
Received By equinone Date 2021-01-29 Time 12:46 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-11-13 Cont ID  
Sent By equinone Date 2020-11-13 Time 12:04 Rev Time 0.00
Received By equinone Date 2020-11-13 Time 12:04 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2020-11-03 Cont ID  
Sent By lcrespo Date 2020-11-03 Time 18:00 Rev Time 0.00
Received By lcrespo Date 2020-11-03 Time 18:00 Sent To  
Notes
2020-11-03 18:01:27GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN
 THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN
 PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS
 WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE
 RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT
 REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER
 THE WPB AMENDMENTS TO FBC SEC. 107.2.1.
  
 A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR
 FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC
 SEC. 105.1.
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2020-11-23 Cont ID  
Sent By fmittner Date 2020-11-23 Time 12:15 Rev Time 0.00
Received By fmittner Date 2020-11-23 Time 12:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-02-05 Cont ID  
Sent By rmcphers Date 2021-02-05 Time 10:13 Rev Time 0.00
Received By rmcphers Date 2021-01-22 Time 16:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-12-02 Cont ID  
Sent By lmarchan Date 2020-12-02 Time 10:53 Rev Time 0.00
Received By lmarchan Date 2020-10-30 Time 10:25 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2021-08-13 Cont ID  
Sent By ccarvaja Date 2021-08-13 Time 14:39 Rev Time 0.00
Received By ccarvaja Date 2021-05-05 Time 15:27 Sent To  
Notes
2021-05-05 15:27:435/5/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-11-16 Cont ID  
Sent By rmcphers Date 2020-11-16 Time 11:26 Rev Time 0.00
Received By rmcphers Date 2020-11-16 Time 11:26 Sent To  
Notes
2020-11-16 11:26:43PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2021-01-25 Cont ID  
Sent By medwards Date 2021-01-25 Time 17:14 Rev Time 0.00
Received By medwards Date 2021-01-25 Time 17:04 Sent To  
Notes
2021-01-25 17:15:14APPROVED 1ST CYCLE NO CHANGES THIS CYCLE. ME

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-11-04 Cont ID  
Sent By medwards Date 2020-11-04 Time 13:56 Rev Time 0.00
Received By medwards Date 2020-11-04 Time 13:41 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-01-26 Cont ID  
Sent By lcrespo Date 2021-01-26 Time 17:22 Rev Time 0.00
Received By lcrespo Date 2021-01-26 Time 17:22 Sent To  
Notes
2021-01-26 17:22:4301/26/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2020-11-03 Cont ID  
Sent By lcrespo Date 2020-11-03 Time 18:19 Rev Time 0.00
Received By lcrespo Date 2020-11-03 Time 18:01 Sent To  
Notes
2020-11-03 18:20:2211/03/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status N Date 2021-05-26 Cont ID  
Sent By rmcphers Date 2021-05-26 Time 08:51 Rev Time 0.00
Received By rmcphers Date 2021-05-26 Time 08:51 Sent To  
Notes
2021-05-26 08:52:24ROOFING TO BE DEFERRED AT THIS TIME
 ITEMS NEEDED FOR ROOFING SYSTEM
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) FOR AIR-PERMEABLE RAFTER SPACE INSULATION - PLEASE
 SHOW THE RIGID BOARD OR SHEET INSULATION ON TOP OF THE
 ROOF SHEATHING TO COMPLY WITH FBC R806.5 UNVENTED ATTIC
 AND UNVENTED ENCLOSED RAFTER ASSEMBLIES. UNVENTED
 ATTICS AND UNVENTED ENCLOSED ROOF FRAMING ASSEMBLIES
 CREATED BY CEILINGS THAT ARE APPLIED DIRECTLY TO THE
 UNDERSIDE OF THE ROOF FRAMING MEMBERS AND STRUCTURAL
 ROOF SHEATHING APPLIED DIRECTLY TO THE TOP OF THE ROOF
 FRAMING MEMBERS/RAFTERS, SHALL BE PERMITTED WHERE ALL
 THE FOLLOWING CONDITIONS ARE MET:
  
 5.INSULATION SHALL BE LOCATED IN ACCORDANCE WITH THE
 FOLLOWING:
  
 5.1.ITEM 5.1.1, 5.1.2, 5.1.3 OR 5.1.4 SHALL BE MET,
 DEPENDING ON THE AIR PERMEABILITY OF THE INSULATION
 DIRECTLY UNDER THE STRUCTURAL ROOF SHEATHING.
  
 5.1.1.WHERE ONLY AIR-IMPERMEABLE INSULATION IS
 PROVIDED, IT SHALL BE APPLIED IN DIRECT CONTACT WITH
 THE UNDERSIDE OF THE STRUCTURAL ROOF SHEATHING.
  
 5.1.2.WHERE AIR-PERMEABLE INSULATION IS PROVIDED INSIDE
 THE BUILDING THERMAL ENVELOPE, IT SHALL BE INSTALLED IN
 ACCORDANCE WITH SECTION 5.1.1. IN ADDITION TO THE
 AIR-PERMEABLE INSULATION INSTALLED DIRECTLY BELOW THE
 STRUCTURAL SHEATHING, RIGID BOARD OR SHEET INSULATION
 SHALL BE INSTALLED DIRECTLY ABOVE THE STRUCTURAL ROOF
 SHEATHING IN ACCORDANCE WITH THE R-VALUES IN TABLE
 R806.5 FOR CONDENSATION CONTROL.
  
  
 2) PLEASE PROVIDE A COMPLETE MIAMI DADE OR FLORIDA
 STATE PRODUCT APPROVAL FOR THE ROOFING TILE - PLEASE
 CIRCLE THE TILE ATTACHMENT TO BE USED IN THE PRODUCT
 APPROVAL - IF USING ADHESIVE PLEASE PROVIDE THE PRODUCT
 APPROVAL FOR THE ADHESIVE.
  
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2021-02-05 Cont ID  
Sent By rmcphers Date 2021-02-05 Time 10:09 Rev Time 0.00
Received By rmcphers Date 2021-02-05 Time 10:09 Sent To  
Notes
2021-02-05 10:11:34SEE BUILDING PLAN REVIEW

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2020-11-16 Cont ID  
Sent By rmcphers Date 2020-11-16 Time 11:26 Rev Time 0.00
Received By rmcphers Date 2020-11-16 Time 11:26 Sent To  
Notes
2020-11-16 11:27:11SEE BUILDING PLAN REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-08-18 Cont ID  
Sent By shill Date 2021-08-18 Time 16:08 Rev Time 0.00
Received By shill Date 2021-08-18 Time 16:08 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-01-25 Cont ID  
Sent By medwards Date 2021-01-25 Time 06:55 Rev Time 0.00
Received By medwards Date 2021-01-25 Time 06:53 Sent To  
Notes
2021-01-25 06:58:18ORIGINAL SIGNED AND SEALED PAPER DRAWINGS OR DIGITALLY
 SUBMITTED SIGNED AND SEALED DRAWINGS WILL NEED TO BE
 SUBMITTED FOR REVIEW. THESE COPIES APPEAR TO BE COPIES
 OF A DIGITALLY SIGNED AND SEALED DRAWINGS. AS OF DEC.
 30 2020 WE CAN NO LONGER ACCEPT A COPY OF A DIGITAL
 SIGNATURE.
  
 PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-10-30 Cont ID  
Sent By equinone Date 2020-10-30 Time 14:46 Rev Time 0.00
Received By equinone Date 2020-10-30 Time 14:46 Sent To  
Notes
2020-10-30 14:47:14PAPER DRAWINGS HAVE ORIGINAL SEAL AND SIGNATURE. ROUTED
 TO STORAGE. EQ

Review Stop Z ZONING
Rev No 1 Status P Date 2020-11-23 Cont ID  
Sent By fmittner Date 2020-11-23 Time 12:15 Rev Time 0.00
Received By fmittner Date 2020-11-23 Time 12:15 Sent To  
Notes
***NONE***