Plan Review Details - Permit 20101189
Plan Review Stops For Permit 20101189
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2021-01-19 Cont ID  
Sent By cpuell Date 2021-01-19 Time 16:37 Rev Time 0.00
Received By cpuell Date 2021-01-19 Time 16:37 Sent To  
Notes
2021-01-19 16:38:20INFO GIVEN AND DESCRIPTION UPDATED

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2020-11-19 Cont ID  
Sent By cpuell Date 2020-11-19 Time 17:21 Rev Time 0.00
Received By cpuell Date 2020-11-19 Time 17:21 Sent To  
Notes
2020-11-19 17:22:04PLEASE PROVIDE A SURVEY OR SITE PLAN, SHOWING THE EXACT
 LOCATION OF THE SIGN, PLEASE EMAIL TO [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2021-04-15 Cont ID  
Sent By jgomez Date 2021-04-15 Time 09:50 Rev Time 0.00
Received By jgomez Date 2021-04-14 Time 18:35 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2021-01-29 Cont ID  
Sent By jgomez Date 2021-01-29 Time 11:04 Rev Time 0.00
Received By jgomez Date 2021-01-29 Time 10:56 Sent To  
Notes
2021-01-29 11:11:08SIGN THIRD BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
 PERMIT #20101189
  
 NOTE: SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK
 SHALL COMPLY WITH THE MATERIALS AND METHODS
 REQUIREMENTS IN THE FLORIDA BUILDING CODE.
  
 1- COMPLIED .
  
 ORIGINAL COMMENT FROM PREVIOUS PLANS EXAMINER:
 2. FBC B 1609 PROVIDE A COMPLETE SET OF SIGNED AND
 SEALED ENGINEERED WIND DESIGN CALCULATIONS ALONG WITH
 INSTALLATION METHOD FOR PROPOSED NEW WALL SIGN.
  
 RESPONSE:
 ENGINEER'S CALCULATIONS EMAILED BY LAUREN MEEKER ON
 01/28/2021 NEED TO BE REVISED. CALCULATIONS SUBMITTED
 ARE FOR THE ORIGINAL DESIGN SHOWING A CANOPY WITH A 2
 FEET PROJECTION. THE CANOPY WAS REVISED TO 4 FEET
 PROJECTION. CALCULATIONS NEED TO BE REVISED ACCORDINGLY
 AND RESUBMITTED TO PROJECTDOX.
 SEC. 1609.1 FBC-BUILDING.
  
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-01-27 Cont ID  
Sent By jgomez Date 2021-01-27 Time 09:40 Rev Time 0.00
Received By jgomez Date 2021-01-27 Time 09:40 Sent To  
Notes
2021-01-27 09:41:19SIGN SECOND BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
 PERMIT #20101189
  
 NOTE: SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK
 SHALL COMPLY WITH THE MATERIALS AND METHODS
 REQUIREMENTS IN THE FLORIDA BUILDING CODE.
  
 1- COMPLIED .
  
 ORIGINAL COMMENT FROM PREVIOUS PLANS EXAMINER:
 2. FBC B 1609 PROVIDE A COMPLETE SET OF SIGNED AND
 SEALED ENGINEERED WIND DESIGN CALCULATIONS ALONG WITH
 INSTALLATION METHOD FOR PROPOSED NEW WALL SIGN.
  
 RESPONSE:
 ENGINEERED PLANS SUBMITTED ARE MISSING THE REQUESTED
 WIND DESIGN INFORMATION. SEE SEC. 1609.1, SEC. 1609.1.1
 AND SEC. 1603.1.4 FBC-BUILDING AND PROVIDE REQUIRED
 INFORMATION.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-10-29 Cont ID  
Sent By jbrooks Date 2020-10-29 Time 14:05 Rev Time 0.00
Received By jbrooks Date 2020-10-29 Time 13:45 Sent To  
Notes
2020-10-29 14:05:54JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM
 ALTERNATE: CONTACT PETER VALENTI (561) 805-6673
 [email protected]
  
 1ST REVIEW: FBC 2017 6TH EDITION
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected] AND REQUEST
 THAT IT BE CONVERTED TO PROJECTDOX.
  
 1. FBC B 107.1 FS 481.229 ( C ) BUILDINGS INTENDED FOR
 PUBLIC USE; PLANS REQUIRE PREPARATION BY A REGISTERED
 DESIGN PROFESSIONAL. PROVIDE A COMPLETE SET.
 2. FBC B 1609 PROVIDE A COMPLETE SET OF SIGNED AND
 SEALED ENGINEERED WIND DESIGN CALCULATIONS ALONG WITH
 INSTALLATION METHOD FOR PROPOSED NEW WALL SIGN.
  

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2020-11-05 Cont ID  
Sent By fgiaquin Date 2020-11-05 Time 21:32 Rev Time 0.00
Received By fgiaquin Date 2020-11-05 Time 21:09 Sent To  
Notes
2020-11-05 21:32:35NON-ILLUMINATED SIGN, NO ELECTRICAL WORK REVIEWED OR
 APPROVED

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-04-15 Cont ID  
Sent By jgomez Date 2021-04-15 Time 10:18 Rev Time 0.00
Received By jgomez Date 2021-03-16 Time 14:55 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-03-03 Cont ID  
Sent By lmarchan Date 2021-03-03 Time 11:05 Rev Time 0.00
Received By lmarchan Date 2021-01-21 Time 10:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-11-19 Cont ID  
Sent By cpuell Date 2020-11-19 Time 17:22 Rev Time 0.00
Received By cpuell Date 2020-10-26 Time 12:49 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2021-04-15 Cont ID  
Sent By jgomez Date 2021-04-15 Time 11:07 Rev Time 0.00
Received By jgomez Date 2021-04-15 Time 11:07 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2021-04-15 Cont ID  
Sent By jgomez Date 2021-04-15 Time 10:07 Rev Time 0.00
Received By jgomez Date 2021-04-15 Time 10:04 Sent To  
Notes
2021-04-15 10:12:12SIGNATURE REVIEW COMMENTS.
  
 1- UNABLE TO VERIFY ENGINEER'S DIGITAL SIGNATURE. IT
 LOOKS LIKE THE PLANS MIGHT HAVE LOST THE DIGITAL
 SIGNATURE WHEN THE CITY PLACE STAMP WAS PLACED. TO
 EXPEDITE THE SIGNATURE REVIEW PROCESS, PLEASE UPLOAD
 DRAWINGS WITH ENGINEER'S DIGITAL SIGNATURE TO THE
 SIGNATURE FOLDER.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-01-27 Cont ID  
Sent By jgomez Date 2021-01-27 Time 10:02 Rev Time 0.00
Received By jgomez Date 2021-01-27 Time 10:02 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-10-29 Cont ID  
Sent By jbrooks Date 2020-10-29 Time 14:06 Rev Time 0.00
Received By jbrooks Date 2020-10-29 Time 13:45 Sent To  
Notes
2020-10-29 14:06:45JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM
 ALTERNATE: CONTACT PETER VALENTI (561) 805-6673
 [email protected]
  
 1ST REVIEW: FBC 2017 6TH EDITION
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
  
 FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN
 ORIGINAL.
 EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN
 TO ME, OR YOU CAN MAIL ONE ORIGINAL SIGNED AND SEALED
 PAPER ORIGINAL WITH A WET SIGNATURE TO:
 PETER VALENTI
 BUILDING PLANS EXAMINER II
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,
 561-805-6673.
  

Review Stop Z ZONING
Rev No 3 Status P Date 2021-03-30 Cont ID  
Sent By eschneid Date 2021-03-30 Time 17:23 Rev Time 0.25
Received By eschneid Date 2021-03-30 Time 16:40 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2021-03-03 Cont ID  
Sent By eschneid Date 2021-03-03 Time 08:51 Rev Time 0.25
Received By eschneid Date 2021-03-03 Time 08:28 Sent To  
Notes
2021-03-03 08:51:54FAILED
  
 PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 1) THE REVISED PLANS NEED TO INCLUDE THE CITYPLACE
 RETAIL MANAGEMENT APPROVAL STAMP OR A SIGNED LETTER
 THAT CITES THE PLANS THAT ARE PART OF THE PERMIT
 SUBMITTAL. THE PREVIOUS STAMP WAS FOR AN INCORRECT
 DESIGN.
  
 2) THE ALUMINUM BAR SHOWN AS INCLUDED WITH THE SIGN
 MOUNTED TO IT IS CLASSIFIED AS A CANOPY UNDER THE
 ROSEMARY SQUARE TENANT SIGN CRITERIA.
  
 A. REVISED COMMENT: THE ROSEMARY SQUARE TENANT SIGN
 CRITERIA CONTAIN SPECIFIC REQUIREMENTS FOR CANOPIES,
 INCLUDING THAT THE CANOPY PROJECT A MINIMUM OF EIGHT
 (8) FEET FROM THE WALL. THE ROSEMARY SQUARE TENANT SIGN
 CRITERIA INCLUDE A WAIVER I PROVISION THAT PERMITS THE
 CANOPY PROJECTION TO BE REDUCED TO FOUR (4) FEET. THE
 WAIVER I APPROVAL REQUIRES THE SUBMITTAL OF WRITTEN
 APPROVAL FROM CITYPLACE, LLC, OF THE SPECIFIC
 PROVISIONS BEING WAIVED WITH THE PERMIT. THE WAIVER I
 APPROVAL HAS NOT BEEN SUBMITTED.
  
 B. THE ROSEMARY SQUARE TENANT SIGN CRITERIA CONTAIN
 SPECIFIC REQUIREMENTS FOR CANOPIES, INCLUDING THAT THE
 CANOPY HAS A MINIMUM VERTICAL CLEARANCE FROM THE
 SIDEWALK ELEVATION OF TEN (10) FEET. PROVIDE THE
 DIMENSION FROM THE SIDEWALK (NOT THE ROADWAY) THAT
 VERIFIES THE MINIMUM REQUIRED HEIGHT. THE RESUBMITTED
 PLANS SHOW 0 FEET 0 INCHES AFF.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2020-11-19 Cont ID  
Sent By eschneid Date 2020-11-19 Time 15:55 Rev Time 0.50
Received By eschneid Date 2020-11-17 Time 14:37 Sent To  
Notes
2020-11-19 16:00:37FAILED
  
 PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 1) THE PLANS INCLUDE A NOTE THAT THE SIGN WILL BE
 PLACED ON THE EAST ELEVATION. THE HIBISCUS GARAGE DOES
 NOT HAVE AN ENTRANCE ON THE EAST SIDE AS THIS IS THE
 FEC RAILROAD. THE CORRECT CONDITIONS MUST BE SHOWN.
 PROVIDE A SITE PLAN SHOWING THE SIGN'S LOCATION.
  
 2) THE ALUMINUM BAR SHOWN AS INCLUDED WITH THE SIGN
 MOUNTED TO IT IS CLASSIFIED AS A CANOPY UNDER THE
 ROSEMARY SQUARE TENANT SIGN CRITERIA.
  
 A. THE ROSEMARY SQUARE TENANT SIGN CRITERIA CONTAIN
 SPECIFIC REQUIREMENTS FOR CANOPIES, INCLUDING THAT THE
 CANOPY PROJECT A MINIMUM OF EIGHT (8) FEET FROM THE
 WALL. THE PROPOSED CANOPY ONLY PROJECTS TWO (2) FEET
 FROM THE WALL. THE ROSEMARY SQUARE TENANT SIGN CRITERIA
 INCLUDE A WAIVER I PROVISION THAT PERMITS THE CANOPY
 PROJECTION TO BE REDUCED TO FOUR (4) FEET. A WAIVER I
 IS APPROVED IN WRITING BY CITYPLACE RETAIL, LLC.
  
 B. THE ROSEMARY SQUARE TENANT SIGN CRITERIA CONTAIN
 SPECIFIC REQUIREMENTS FOR CANOPIES, INCLUDING THAT THE
 CANOPY HAS A MINIMUM VERTICAL CLEARANCE FROM THE
 SIDEWALK ELEVATION OF TEN (10) FEET. PROVIDE THE
 DIMENSION FROM THE SIDEWALK (NOT THE ROADWAY) THAT
 VERIFIES THE MINIMUM REQUIRED HEIGHT.
  
 3) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE
 THAT RIVETS, SCREWS AND OTHER FASTENERS THAT EXTEND TO
 VISIBLE SURFACES SHALL BE FLUSH, FILLED AND FINISHED SO
 AS TO BE UNNOTICEABLE. THE PLANS SHOW THE STUD WEDGE
 ANCHOR EXTENDING PAST THE WALL IN THE SECTION VIEW;
 HOWEVER, NO INFORMATION IS PROVIDED THAT THE BOLTS ARE
 COVERED FROM THE FRONT OR SIDES. PROVIDE VERIFICATION
 THAT THE BOLTS SECURING THE CANOPY TO THE WALL MEET
 THIS CRITERION. THIS CAN BE ACHIEVED BY USING CAPS
 PAINTED TO MATCH THE BRACKET COLOR.
  
 4) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE
 THAT ALL INSTALLATION COMPONENTS OR HANGING DEVICES
 CONSIST OF ANODIZED ALUMINUM. PROVIDE ON THE PLANS
 VERIFICATION THAT THE MOUNTING PLATE IS ANODIZED
 ALUMINUM.
  
 5) THE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT UP
 TO THREE COLORS ON A SIGN. PROVIDE ON THE PLANS
 VERIFICATION OF THE COLORS USED ON THE SIGN.
  
 6) PLEASE CLARIFY HOW THE SIGN WILL BE ILLUMINATED.
  
 7) THE PROPOSED SIGN IS A WAYFINDING SIGN.
  
 A. THE ROSEMARY SQUARE TENANT SIGN CRITERIA DO NOT SHOW
 THE PROPOSED SIGN AS AN APPROVED SIGN TYPE. THE
 ROSEMARY SQUARE TENANT SIGN CRITERIA INCLUDE A WAIVER
 II PROVISION THAT PERMITS, "ALTERNATIVE PLACEMENT,
 DESIGN OR QUANTITY OF WAYFINDING SIGNS (DIRECTIONAL OR
 INFORMATIONAL) FROM THAT WHICH IS DEPICTED ON THE
 WAYFINDING SIGN LOCATION MAP UNDER ROSEMARY SQUARE
 WAYFINDING SIGN CRITERIA (EXHIBIT D)". THE WAIVER II IS
 A MINOR PLANNED DEVELOPMENT AMENDMENT THAT MUST BE
 SUBMITTED TO AND APPROVED BY THE PLANNING DIVISION
 PRIOR TO THE ZONING SIGN OFF FOR A SIGN AT THIS
 LOCATION. THE WAIVER II WILL NEED TO JUSTIFY THE SIZE
 AND DESIGN OF THE PROPOSED SIGN, INCLUDING THE COLORS
 OF THE VARIOUS SIGN ELEMENTS (IF MORE THAN THREE
 COLORS).
  
 B. ALTERNATIVELY, THIS SIGN CAN BE REVIEWED AS A CANOPY
 SIGN. THE RESPONSES TO COMMENTS 3-6 WILL BE USED TO
 VERIFY IF IT COMPLIES WITH THE CANOPY SIGN REQUIREMENTS
 IF THIS IS THE SIGN TYPE CHOSEN.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  