Plan Review Stops For Permit 20101176 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2020-11-06 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-11-06 |
Time |
11:49 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-11-06 |
Time |
11:49 |
Sent To |
|
|
Notes |
2020-11-06 11:50:27 | APPLICANT REACHED PUT TO ME 6/2/2020 NEW ADDRESS | | ESTANLISHED AS 221 A E ISAACS AVE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-01-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-01-14 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-01-14 |
Time |
15:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-11-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-06 |
Time |
08:24 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-05 |
Time |
16:30 |
Sent To |
|
|
Notes |
2020-11-06 08:40:31 | PLAN REVIEW / BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NEC 2014 | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | RE: | | | | 1. PROVIDE A SOILS REPORT. | | GEOTECHNICAL INVESTIGATIONS | | FBC 1803.1 GENERAL. GEOTECHNICAL INVESTIGATIONS SHALL | | BE CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND | | REPORTED IN ACCORDANCE WITH SECTION 1803.6. WHERE | | REQUIRED BY THE BUILDING OFFICIAL OR WHERE GEOTECHNICAL | | INVESTIGATIONS INVOLVE IN-SITU TESTING, LABORATORY | | TESTING OR ENGINEERING CALCULATIONS, SUCH | | INVESTIGATIONS SHALL BE CONDUCTED BY A REGISTERED | | DESIGN PROFESSIONAL. | | | | 2. PROVIDE THE FINISHED FLOOR ELEVATION. | | R403.1.7.3 FOUNDATION ELEVATION. | | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION | | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER | | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED | | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 | | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO | | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN | | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF | | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT | | ALL LOCATIONS ON THE SITE. | | | | FINISHED FLOOR ELEVATIONS SHALL BE PLACED ON FOUNDATION | | PLAN AND/OR FLOOR PLAN. | | | | 3. PROVIDE A SITE DRAINAGE PLAN AND SURVEY. | | FBC R401.3 SITE DRAINAGE | | PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH | | FBC R401.3 DRAINAGE. | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | DOES NOT CREATE A HAZARD. | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | INCHES WITHIN THE FIRST 10 FEET. | | | | NOTE-1: VALUE HAS BEEN ADJUSTED TO $219,741.00 BASED ON | | THE ICC BUILDING VALUATION TABLES. | | | | NOTE-2: PALM BEACH COUNTY IMPACT FEES REQUIRED. SEE | | COMMENTS UNDER IMPACT FEE REVIEW. | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2021-01-15 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-01-15 |
Time |
12:31 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-01-15 |
Time |
12:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-11-12 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2020-11-12 |
Time |
13:27 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2020-11-12 |
Time |
13:27 |
Sent To |
|
|
Notes |
2020-11-12 13:27:34 | CODES IN EFFECT | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | REVIEW STATUS: FAILED | | | | 1) OUTDOOR RECEPTACLE REQUIRED ON BACK OF STRUCTURE. | | MUST BE WEATHERPROOF AND GFCI PROTECTED. FBC RE | | E3902.3, E3901.7 | | 2) RECEPTACLE IN LAUNDRY AREA MUST BE GFCI PROTECTED. | | FBC RE E3902.9 | | 3) BEDROOM 2 AND HALLWAY AREA IN FRONT OF BEDROOMS 1 | | AND 2 SEEM TO BE MISSING SOME REQUIRED GENERAL-PURPOSE | | RECEPTACLES. FBC RE E3901.2, FBC RE E3901.10 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. | | | | SINCERELY, | | | | ENRIQUE QUINONEZ | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-01-19 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-01-19 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-01-08 |
Time |
19:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-11-16 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-11-16 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-10-28 |
Time |
16:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2021-02-09 |
|
|
Cont ID |
|
Sent By |
ccarvaja |
Date |
2021-02-08 |
Time |
12:44 |
Rev Time |
0.00 |
Received By |
ccarvaja |
Date |
2021-01-19 |
Time |
15:52 |
Sent To |
|
|
Notes |
2021-02-09 12:45:44 | 02/08/21 RECEIPT MU-2021-002912-000 - $4,458.88 - PAID. | | CC | 2021-01-19 15:53:15 | 1/19/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2020-11-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-06 |
Time |
08:17 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-06 |
Time |
08:17 |
Sent To |
|
|
Notes |
2020-11-06 08:18:32 | IMPACT FEES - DIGITAL SUBMITTALS | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | YOUR PROJECT OR EMAIL IT TO [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2021-01-19 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-01-19 |
Time |
12:58 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-01-19 |
Time |
12:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2021-01-12 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-01-12 |
Time |
06:07 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-01-12 |
Time |
06:07 |
Sent To |
|
|
Notes |
2021-01-12 06:10:48 | PLEASE ADDRESS THE FIRST COMMENT OF THE ORIGINAL | | REVIEW. THE MECHANICAL EQUIPMENT SIZING CALCULATIONS DO | | NOT MATCH UP WITH SHEET M-1. THE SQUARE FOOTAGE UNDER | | A/C MUST MATCH. FBC 107.2 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-11-02 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-11-02 |
Time |
16:44 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-11-02 |
Time |
16:04 |
Sent To |
|
|
Notes |
2020-11-02 16:44:27 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT-20101176 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) HVAC LOAD CALCULATIONS ARE FOR 1,257 SQ. FT. BUT | | SHEET M-1 INDICATES THAT THERE IS 1,362 SQ.FT. UNDER | | A/C. PLEASE MAKE SURE THEY MATCH. FBC 107.2 | | | | 2) SHEET M-1: NOTE 1- PLEASE SHOW THE BATH EXHAUST FANS | | AND THE TERMINATION LOCATIONS ON THE DRAWING. FBC 107.2 | | | | 3) SHEET M-1: NOTE 2- PLEASE SHOW THE MICROWAVE EXHAUST | | TERMINATION LOCATION ON THE DRAWING. FBC 107.2 | | | | 4) SHEET M-1: NOTE 5 PLEASE SHOW THE DRYER EXHAUST | | TERMINATION LOCATION ON THE DRAWING. FBC 107.2 | | | | 5) PLEASE LABEL THE AIR CONDENSING UNIT LOCATION AND | | PROVIDE ANCHORAGE DETAILS. FBC RES M1307.2 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2021-01-11 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-01-11 |
Time |
12:48 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-01-11 |
Time |
11:37 |
Sent To |
|
|
Notes |
2021-01-11 12:49:37 | 01/11/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-10-29 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-10-29 |
Time |
08:19 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-10-29 |
Time |
08:05 |
Sent To |
|
|
Notes |
2020-10-29 08:19:04 | 10/29/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | 1. A SUB PLUMBING PERMIT IS REQUIRED BY A LICENSED | | CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS | | TO THE FBC SEC. 105.1. | | | | 2. PLUMBING RISER DIAGRAM REQUIRED PER THE WPB | | AMENDMENTS TO THE FBC SEC. 107.3.5.3 (11) RESIDENTIAL | | PLUMBING. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2020-11-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-06 |
Time |
08:18 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-05 |
Time |
16:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
N |
Date |
2021-07-13 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-07-13 |
Time |
07:14 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-07-13 |
Time |
07:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-01-08 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-01-08 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-01-08 |
Time |
13:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-10-28 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2020-10-28 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2020-10-28 |
Time |
15:15 |
Sent To |
|
|
Notes |
2020-10-28 15:16:23 | PAPER DRAWINGS HAVE DIGITAL SIGNATURE AND SEAL. ROUTED | | TO STORAGE. EQ |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2021-01-19 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2021-01-19 |
Time |
|
Rev Time |
0.00 |
Received By |
rthermid |
Date |
2021-01-19 |
Time |
|
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-11-05 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-11-05 |
Time |
|
Rev Time |
|
Received By |
rthermid |
Date |
2020-11-05 |
Time |
|
Sent To |
I |
|
Notes |
2020-11-05 09:42:17 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: 11/5/2020 | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. PLEASE PROVIDE A SURVEY OF THE PROPERTY INDICATING | | THE SETBACKS OF THE PROPOSED STRUCTURE TO ALL PROPERTY | | LINES. | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | LIKE TO RESUBMIT ELECTRONICALY, EMAIL | | [email protected] AND REQUEST TO HAVE YOUR | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOGIN | | INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | ARE FINISHED UPLOADING. | | | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | TTY: 800.955.8771 | | E: [email protected] | | W: WPB.ORG | | |
|
|