Plan Review Stops For Permit 20101143 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-11-25 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-11-25 |
Time |
13:32 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-11-25 |
Time |
13:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-11-17 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-11-17 |
Time |
13:28 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-11-17 |
Time |
13:12 |
Sent To |
|
|
Notes |
2020-11-17 13:27:45 | GENERATOR | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE SHOW CONCRETE GENERATOR PAD THICKNESS AND ANY | | REQUIRED REINFORCEMENT. FBC 1901.2 | | 2) PLEASE PROVIDE SIGNED AND SEALED GENERATOR TIEDOWN | | REQUIREMENTS SHOWING THE WIND DESIGN DATA USED FROM AN | | ARCHITECT OR ENGINEER PER FBC 1603.1 TO COMPLY WITH THE | | REQUIRED WIND LOADS PER FBC 1609 | | 3) PLEASE SHOW THE CONCRETE PAD SETBACKS FROM THE | | PROPERTY LINES AND THE WATER RUN OFF TO BE MAINTAINED | | ON THIS PROPERTY. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-12-02 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2020-12-02 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2020-12-02 |
Time |
10:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-11-16 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2020-11-16 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2020-11-16 |
Time |
13:10 |
Sent To |
|
|
Notes |
2020-11-16 16:00:16 | CODES IN EFFECT | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | REVIEW STATUS: FAILED. PLEASE SEE COMMENTS BELOW: | | | | 1) SHEET NUMBER E-3.0 KEYNOTE NUMBER 2 STATES THAT | | GENERATOR IS NOT A SEPARATELY DERIVED SYSTEM. RISER | | DIAGRAMS SHOWS A #6 GROUND AT THE GENERATOR. FOR | | GENERATORS INSTALLED AS NOT SEPARATELY DERIVED SYSTEM | | NORMALLY THE EQUIPMENT GROUNDING CONDUCTOR THAT IS PART | | OF THE FIVE WIRE FEEDER FROM THE GENERATOR TO THE | | TRANSFER EQUIPMENT WILL GROUND AND BOND ALL OF THE | | NON-CURRENT CARRYING METAL PARTS OF THE GENERATOR | | THROUGH THE TRANSFER EQUIPMENT TO THE GROUNDING | | ELECTRODE SYSTEM BACK AT THE SERVICE. NEC 250.35. ONLY | | ONE FAULT RETURN PATH SHOULD EXIST. | | 2) PROVIDE NOTE REQUIRING WARNING LABEL TO COMPLY WITH | | NEC 702.7 | | 3) SEE SIGNATURE COMMENTS. | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. | | | | SINCERELY, | | | | ENRIQUE QUINONEZ | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2020-11-25 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-11-25 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-11-25 |
Time |
09:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2020-11-19 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-11-19 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-11-19 |
Time |
10:53 |
Sent To |
|
|
Notes |
2020-11-19 11:17:05 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) SHEET # 3.0 INDICATES THE FUEL TYPE AS NATURAL GAS; | | HOWEVER, THERE IS NO INDICATIONS OF A FUEL LINE TO THE | | GENERATOR. | | | | PLEASE PROVIDE DETAILS OF THE LOCATION AND SIZE OF THE | | FUEL LINE IN COMPLAINCE WITH THE REQUIRMENTS OF NFPA | | 54. | | | | 5.1 PIPING PLAN. | | 5.1.1 INSTALLATION OF PIPING SYSTEM. WHERE REQUIRED BY | | THE | | AUTHORITY HAVING JURISDICTION, A PIPING SKETCH OR PLAN | | SHALL BE | | PREPARED BEFORE PROCEEDING WITH THE INSTALLATION. THE | | PLAN | | SHALL SHOW THE PROPOSED LOCATION OF PIPING, THE SIZE OF | | DIFFERENT | | BRANCHES, THE VARIOUS LOAD DEMANDS, AND THE LOCATION OF | | THE POINT OF DELIVERY. | | | | CHAPTER 7 GAS PIPING INSTALLATION | | 7.1 PIPING UNDERGROUND. | | 7.1.1 CLEARANCES. UNDERGROUND GAS PIPING SHALL BE | | INSTALLED | | WITH SUFFICIENT CLEARANCE FROM ANY OTHER UNDERGROUND | | STRUCTURE | | TO AVOID CONTACT THEREWITH, TO ALLOW MAINTENANCE, AND | | TO PROTECT | | AGAINST DAMAGE FROM PROXIMITY TO OTHER STRUCTURES. IN | | ADDITION, | | UNDERGROUND PLASTIC PIPING SHALL BE INSTALLED WITH | | SUFFICIENT | | CLEARANCE OR SHALL BE INSULATED FROM ANY SOURCE OF HEAT | | SO AS TO | | PREVENT THE HEAT FROM IMPAIRING THE SERVICEABILITY OF | | THE PIPE. | | 7.1.2 PROTECTION AGAINST DAMAGE. MEANS SHALL BE | | PROVIDED TO | | PREVENT EXCESSIVE STRESSING OF THE PIPING WHERE | | VEHICULAR TRAFFIC IS | | HEAVY OR SOIL CONDITIONS ARE UNSTABLE AND SETTLING OF | | PIPING OR | | FOUNDATION WALLS COULD OCCUR. PIPING SHALL BE BURIED OR | | COVERED | | IN A MANNER SO AS TO PROTECT THE PIPING FROM PHYSICAL | | DAMAGE. | | PIPING SHALL BE PROTECTED FROM PHYSICAL DAMAGE WHERE IT | | PASSES | | THROUGH FLOWER BEDS, SHRUB BEDS, AND OTHER SUCH | | CULTIVATED AREAS | | WHERE SUCH DAMAGE IS REASONABLY EXPECTED. | | 7.1.2.1 COVER REQUIREMENTS. UNDERGROUND PIPING SYSTEMS | | SHALL BE INSTALLED WITH A MINIMUM OF 12 IN. (300 MM) OF | | COVER. | | | | (A) THE MINIMUM COVER SHALL BE INCREASED TO 18 IN. | | (460MM)IF | | EXTERNAL DAMAGE TO THE PIPE OR TUBING FROM EXTERNAL | | FORCES IS | | LIKELY TO RESULT.*******LIKE A UNDER A PARKING | | LOT******** | | | | | | | | 2) SHEET E 1.0 - THERE ARE NO DIMENSIONS INDICATED | | AROUND THE LOCATION OF THE GENERATOR. | | | | 7.2.6 THE EPS EQUIPMENT SHALL BE INSTALLED IN A | | LOCATION THAT | | PERMITS READY ACCESSIBILITY AND A MINIMUM OF 0.9M(36 | | IN.) FROM | | THE SKID RAILS? OUTERMOST POINT IN THE DIRECTION OF | | ACCESS FOR INSPECTION, | | REPAIR, MAINTENANCE, CLEANING, OR REPLACEMENT. THIS | | REQUIREMENT | | SHALL NOT APPLY TO UNITS IN OUTDOOR HOUSINGS. | | | | | | PLEASE PROVIDE DETAILED DIMENSION FROM PROPERTY LINES, | | PAVEMENT EDGES AND BUIDLINGS OR PROVIDE THE SPECIFIC | | MANUFACTURES SPEC SHEETS INDICATING OUTDOOR HOUSING. | | | | | | | | 3) SHEET E 1.0 & E 2.0 - THERE ARE NO ELEVATION | | DIMENSIONS OF THE FOUNDATION. | | | | PER NFPA 110 | | | | 7.4.1.1 SUCH FOUNDATIONS OR STRUCTURAL BASES SHALL | | RAISE THE | | ENGINE AT LEAST 150 MM (6 IN.) ABOVE THE FLOOR OR GRADE | | LEVEL | | AND BE OF SUFFICIENT ELEVATION TO FACILITATE | | LUBRICATING-OIL DRAINAGE | | AND EASE OF MAINTENANCE. | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
N |
Date |
2020-12-09 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-12-09 |
Time |
17:17 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-12-09 |
Time |
17:17 |
Sent To |
|
|
Notes |
2020-12-09 17:18:01 | SEE PERMIT #20120401 ME |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2020-12-01 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-12-01 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-12-01 |
Time |
07:20 |
Sent To |
|
|
Notes |
2020-12-01 08:55:45 | 2ND REVIEW FBC-2017 FUEL GAS | | PERMIT- 20101143 | | 12/1/2020 | | | | CODES IN EFFECT: | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | COMMENTS #6- 14 FROM THE 1ST REVIEW WERE NOT ADDRESSED. | | PLEASE COMPLY. | | | | 6) P3.0: CORRECT THE NOTE SPECIFYING THE ASPHALT PAINT | | ON THE UG GAS LINE- SECTION 404.17 FBC FG. | | | | 7) P3.0: CORRECT OR REMOVE NOTE #4 AT THE GENERATOR | | RISER. IT APPEARS NOTE #5 SHOULD BE PROVIDED TO | | INDICATE 2ND STAGE REGULATOR. SHOW THE REQUIRED PIPE | | UNIONS WITHIN 1 FT. OF EITHER SIDE OF THE REGULATOR- | | SECTIONS 410.1 & 410.2(7) FBC FG, AND SECTION 107.2.1 | | WPB. PLEASE SHOW OR NOTE THE REQUIRED PIPE UNIONS AT | | THE REGULATOR LOCATED ON THE EXTERIOR WALL. | | | | 8) P3.0: INDICATE A FLEXIBLE GAS SUPPLY LINE WILL BE | | INSTALLED AT THE GENERATOR AND PROVIDE THE LENGTH AND | | SIZE- SECTION 411.1 FBC FG. | | | | 9) P1.0 & P3.0: SINGLE DEDICATED AND ACCESSIBLE SHUT | | OFF VALVES FOR THE EQUIPMENT IN THE MAIN LAB ROOM AND | | IN THE EQUIPMENT/COMPRESSOR ROOM SHALL BE PROVIDED. THE | | VALVES SHALL SERVE AS MAIN SHUTOFFS FOR ALL EQUIPMENT | | IN EACH ROOM AND SHALL BE LOCATED ADJACENT TO THE | | EGRESS DOOR FROM THE ROOM OR SPACE, AND SHALL BE | | IDENTIFIED BY APPROVED SIGNAGE STATING "GAS SHUTOFF"- | | SECTION 409.6 FBC FG. | | | | 10) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | GENERATOR AND INTERIOR GAS-FIRED EQUIPMENT. THE SPECS | | SHALL BE HIGHLIGHTED OR MARKED UP TO SHOW THE MBTU/H | | LOADS, INPUT PRESSURES, AND LISTING STANDARDS- SECTIONS | | 301.3, 301.5, & 305.1 FBC FG. | | | | 11) CLARIFY IF THE INTERIOR EQUIPMENT WILL BE DIRECTLY | | CONNECTED VIA THE RIGID PIPING OR IF APPLIANCE | | CONNECTORS OR QUICK DISCONNECT DEVICES WILL BE | | INSTALLED. SUBMIT SPECS FOR ALL MANUFACTURED CONNECTORS | | HIGHLIGHTED OR MARKED UP TO SHOW LISTINGS- SECTION | | 411.1 FBC FG. | | | | 12) PROVIDE COMBUSTION AIR CALCULATIONS FOR THE | | INTERIOR GAS-FIRED EQUIPMENT AND INDICATE HOW THE AIR | | WILL BE PROVIDED- SECTION 304.1 & 305.1 FBC FG. | | | | 13) PLEASE REFER TO SECTION 501.8 ITEMS #10 & 11 FBC | | FG: VENTING SYSTEMS APPEAR NOT TO BE REQUIRED FOR THE | | GAS BURNERS BECAUSE THE TOTAL GAS LOAD IN EACH ROOM | | DOES NOT EXCEED 20 MBTU/H, HOWEVER PLEASE SUBMIT | | MANUFACTURER'S SPECIFICATIONS AND INSTALLATION MANUALS | | FOR THE EQUIPMENT TO CONFIRM COMPLIANCE- SECTION 305.1 | | FBC FG. | | | | 14) REFER TO SECTION 307.2 FBC FG AND PROVIDE | | CONDENSATE DISPOSAL PLANS FOR EQUIPMENT PRODUCING | | LIQUID COMBUSTION BY PRODUCTS. | | | | NEW COMMENT: | | | | 15) INDICATE HOW THE GENERATOR IN THE PARKING LOT WILL | | BE PROTECTED FROM DAMAGE BY VEHICULAR IMPACT- SECTION | | 303.4 FBC FG. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | CCOLE@WPB | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-11-19 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-11-19 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-11-19 |
Time |
07:59 |
Sent To |
|
|
Notes |
2020-11-19 11:13:07 | 1ST REVIEW FBC-2017 FUEL GAS | | PERMIT- 20101143 | | 11/19/2020 | | | | CODES IN EFFECT: | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET P1.0: KEY NOTES AND GAS LOADS MISSING AT SHUT | | OFF VALVE LOCATIONS IN THE EQUIPMENT ROOM AND MODEL | | ROOM- SECTION 107.2.1 WPB. | | | | 2) P1.0 & P3.0: CORRECT THE TOTAL LOAD IN THE FUEL/GAS | | SCHEDULE ON P1.0 TO INDICATE 2424.2 MBTU/H TO MATCH THE | | RISER DRAWING- SECTION 107.2.1 WPB. | | | | 3) P1.0, P2.0, P3.0: CORRECT THE TOTAL LOADS INDICATED | | IN FUEL/GAS/SCHEDULE ON P2.0 TO MATCH THE TOTAL LOADS | | SPECIFIED IN THE OTHER DRAWINGS AND LOAD SUMMARIES- | | SECTION 107.2.1 WPB. | | | | 4) P3.0: SHOW THE TOTAL MBTU/H LOAD AT THE METER AND | | THE LOAD AT THE GENERATOR. CORRECT THE TOTAL LOAD IN | | THE FUEL/GAS SCHEDULE- SECTION 107.2.1 WPB. | | | | 5) P3.0: CORRECT THE NFPA 58 REFERENCE IN THE GAS | | NOTES. NFPA 58 IS THE LIQUIFIED PETROLEUM GAS CODE- SEE | | FBC FG REFERENCED STANDARDS. | | | | 6) P3.0: CORRECT THE NOTE SPECIFYING THE ASPHALT PAINT | | ON THE UG GAS LINE- SECTION 404.17 FBC FG. | | | | 7) P3.0: CORRECT OR REMOVE NOTE #4 AT THE GENERATOR | | RISER. IT APPEARS NOTE #5 SHOULD BE PROVIDED TO | | INDICATE 2ND STAGE REGULATOR. SHOW THE REQUIRED PIPE | | UNIONS WITHIN 1 FT. OF EITHER SIDE OF THE REGULATOR- | | SECTIONS 410.1 & 410.2(7) FBC FG, AND SECTION 107.2.1 | | WPB. PLEASE SHOW OR NOTE THE REQUIRED PIPE UNIONS AT | | THE REGULATOR LOCATED ON THE EXTERIOR WALL. | | | | 8) P3.0: INDICATE A FLEXIBLE GAS SUPPLY LINE WILL BE | | INSTALLED AT THE GENERATOR AND PROVIDE THE LENGTH AND | | SIZE- SECTION 411.1 FBC FG. | | | | 9) P1.0 & P3.0: SINGLE DEDICATED AND ACCESSIBLE SHUT | | OFF VALVES FOR THE EQUIPMENT IN THE MAIN LAB ROOM AND | | IN THE EQUIPMENT/COMPRESSOR ROOM SHALL BE PROVIDED. THE | | VALVES SHALL SERVE AS MAIN SHUTOFFS FOR ALL EQUIPMENT | | IN EACH ROOM AND SHALL BE LOCATED ADJACENT TO THE | | EGRESS DOOR FROM THE ROOM OR SPACE, AND SHALL BE | | IDENTIFIED BY APPROVED SIGNAGE STATING "GAS SHUTOFF"- | | SECTION 409.6 FBC FG. | | | | 10) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | GENERATOR AND INTERIOR GAS-FIRED EQUIPMENT. THE SPECS | | SHALL BE HIGHLIGHTED OR MARKED UP TO SHOW THE MBTU/H | | LOADS, INPUT PRESSURES, AND LISTING STANDARDS- SECTIONS | | 301.3, 301.5, & 305.1 FBC FG. | | | | 11) CLARIFY IF THE INTERIOR EQUIPMENT WILL BE DIRECTLY | | CONNECTED VIA THE RIGID PIPING OR IF APPLIANCE | | CONNECTORS OR QUICK DISCONNECT DEVICES WILL BE | | INSTALLED. SUBMIT SPECS FOR ALL MANUFACTURED CONNECTORS | | HIGHLIGHTED OR MARKED UP TO SHOW LISTINGS- SECTION | | 411.1 FBC FG. | | | | 12) PROVIDE COMBUSTION AIR CALCULATIONS FOR THE | | INTERIOR GAS-FIRED EQUIPMENT AND INDICATE HOW THE AIR | | WILL BE PROVIDED- SECTION 304.1 & 305.1 FBC FG. | | | | 13) PLEASE REFER TO SECTION 501.8 ITEMS #10 & 11 FBC | | FG: VENTING SYSTEMS APPEAR NOT TO BE REQUIRED FOR THE | | GAS BURNERS BECAUSE THE TOTAL GAS LOAD IN EACH ROOM | | DOES NOT EXCEED 20 MBTU/H, HOWEVER PLEASE SUBMIT | | MANUFACTURER'S SPECIFICATIONS AND INSTALLATION MANUALS | | FOR THE EQUIPMENT TO CONFIRM COMPLIANCE- SECTION 305.1 | | FBC FG. | | | | 14) REFER TO SECTION 307.2 FBC FG AND PROVIDE | | CONDENSATE DISPOSAL PLANS FOR EQUIPMENT PRODUCING | | LIQUID COMBUSTION BY PRODUCTS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | CCOLE@WPB | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-12-15 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-12-15 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-12-09 |
Time |
09:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-12-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-12-03 |
Time |
18:32 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-11-24 |
Time |
08:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-11-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-11-19 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-11-12 |
Time |
21:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
N |
Date |
2020-12-09 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-12-09 |
Time |
17:19 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-12-09 |
Time |
17:19 |
Sent To |
|
|
Notes |
2020-12-09 17:19:50 | SEE PERMIT #20120511 FOR THE AIR COMPRESSOR. ME |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2020-12-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-12-09 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-12-09 |
Time |
10:18 |
Sent To |
|
|
Notes |
2020-12-09 10:18:42 | SEPARATE PERMIT REQUIRED (AIR COMPRESSOR LINES CANNOT | | BE ON A GENERATOR PERMIT) | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-12-07 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-12-07 |
Time |
09:31 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-12-07 |
Time |
09:31 |
Sent To |
|
|
Notes |
2020-12-07 09:32:47 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT- 20101143 | | 11/19/2020 | | | | CODES IN EFFECT: | | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET P4.0 SUBMIT MANUFACTURER'S SPECIFICATIONS FOR | | THE COMPRESSORS, COMPRESSED AIR PIPING, AND PIPE | | CONNECTORS TO EQUIPMENT- SECTION 1003.1 AND 1003.2 FBC | | M. THE SPECS SHALL SHOW THE MAXIMUM PRESSURE RATINGS OF | | THE COMPRESSORS, PIPING, AND CONNECTORS. | | | | 2) P4.0: INDICATE ON THE PLAN THE TYPE OF COMPRESSED | | AIR PIPING AND PIPE SLEEVES TO BE INSTALLED- SECTION | | 1003.2 FBC M. PROVIDE PIPE SUPPORT AND HANGING DETAILS- | | TYPES, SIZES, AND SPACINGS OF HANGERS. | | | | 3) P4.0: SUBMIT SPECS FOR THE AIR INTAKES AT THE | | EXTERIOR WALL AND PROVIDE A DETAIL SHOWING HOW THE AIR | | WILL BE DUCTED TO THE CEILING AIR INTAKE. CLARIFY HOW | | THE AMOUNT OF REQUIRED AIR FOR THE COMPRESSOR ROOM WAS | | DETERMINED OR CALCULATED- SECTION 107.2.1 WPB. | | | | 4) P4.0: SHOW HOW CONDENSATION FROM THE COMPRESSORS | | WILL BE DRAINED AND DISPOSED OF- SECTION 307.1 FBC M. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
N |
Date |
2020-12-09 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-12-09 |
Time |
17:20 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-12-09 |
Time |
17:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2020-12-01 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-12-01 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-12-01 |
Time |
07:20 |
Sent To |
|
|
Notes |
2020-12-01 09:19:06 | THE PLUMBING REVIEW COMMENTS FOR THE AIR COMPRESSOR AND | | PIPING WERE MOVED TO THE MECHANICAL REVIEW. | | CCOLE- 12/7/20 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-11-19 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-11-19 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-11-19 |
Time |
07:59 |
Sent To |
|
|
Notes |
2020-12-07 09:34:53 | THE PLUMBING REVIEW COMMENTS FOR THE AIR COMPRESSOR AND | | PIPING WERE MOVED TO THE MECHANICAL REVIEW. | | CCOLE- 12/7/20 | | | 2020-11-19 11:50:36 | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
P |
Date |
2020-12-11 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-12-11 |
Time |
17:31 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-12-11 |
Time |
17:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
F |
Date |
2020-12-09 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-12-09 |
Time |
17:20 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-12-09 |
Time |
17:20 |
Sent To |
|
|
Notes |
2020-12-09 17:21:11 | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2020-11-25 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-11-25 |
Time |
13:32 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-11-25 |
Time |
13:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2020-11-17 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-11-17 |
Time |
13:29 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-11-17 |
Time |
13:29 |
Sent To |
|
|
Notes |
2020-11-17 13:29:31 | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | ARCHITECT OR ENGINEER DOES NOT HAVE AN ELECTRONIC OR | | DIGITAL SIGNATURE - PLEASE DROP OFF (CITY HALL DROP | | BOX) THE ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS | | ALONG WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE | | REASON FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN | | REVIEW REQUEST FORM CAN BE OBTAINED BY E MAILING | | [email protected] AND ASKING FOR THE FORM. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-11-16 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2020-11-16 |
Time |
14:41 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2020-11-16 |
Time |
14:41 |
Sent To |
|
|
Notes |
2020-11-16 14:44:17 | ENRIQUE QUINONEZ | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6746 | | | | ELECTRICAL PLANS AND GAR AND AIR LINES PLANS: DOCUMENTS | | PREPARED BY AN ARCHITECT OR ENGINEER AND SUBMITTED FOR | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | ORIGINAL. FS471, FS481, | | | | EITHER UPLOAD DIGITALLY OR ELECTRONICALLY SIGNED PLANS | | OR YOU CAN SUBMIT SIGNED AND SEALED PAPER ORIGINALS | | WITH A WET SIGNATURE. | | | | ENRIQUE QUINONEZ | | ELECTRICAL PLANS EXAMINER | | DEVELOPMENT SERVICES | | CITY OF WEST PALM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | 561-805-6746. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2020-12-14 |
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2020-12-14 |
Time |
17:00 |
Rev Time |
0.00 |
Received By |
kalexand |
Date |
2020-12-14 |
Time |
17:00 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2020-12-02 |
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2020-12-02 |
Time |
15:01 |
Rev Time |
0.00 |
Received By |
kalexand |
Date |
2020-12-02 |
Time |
15:01 |
Sent To |
I |
|
Notes |
2020-12-02 15:26:46 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. GENERATOR EQUIPMENT ENCROACHES TOO FAR INTO SETBACK. | | PURSUANT TO ZLDR SEC. 94-305 MECHANICAL EQUIPMENT MAY | | NO PROJECT MORE THAN 4FT INTO ANY REQUIRED SETBACK. THE | | REQUIRED SETBACK FOR THIS PARCEL IS 15FT. | | | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | LIKE TO RESUBMIT ELECTRONICALLY, EMAIL | | [email protected] AND REQUEST TO HAVE YOUR | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG | | IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | ARE FINISHED UPLOADING. | | ________________________________________ | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-11-19 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2020-11-19 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2020-11-19 |
Time |
15:15 |
Sent To |
|
|
Notes |
2020-11-19 15:17:46 | 11/19/20- FAILED- PLEASE SHOW SETBACKS OF GENERATOR AND | | AC UNIT FROM THE PROPERTY LINES. | | | | ANGELLA VANN, AICP | | 551-822-1441 | | [email protected] |
|
|