Plan Review Details - Permit 20100957
Plan Review Stops For Permit 20100957
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-11-04 Cont ID  
Sent By rmcdouga Date 2020-11-04 Time 13:51 Rev Time 0.00
Received By rmcdouga Date 2020-11-04 Time 13:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-11-04 Cont ID  
Sent By jleahy Date 2020-11-04 Time 13:05 Rev Time 0.00
Received By jleahy Date 2020-11-04 Time 12:47 Sent To  
Notes
2020-11-04 13:06:36SERVICE AND FEEDER CONDUCTORS TO BE 3/0 JLEAHY

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2020-11-13 Cont ID  
Sent By ccole Date 2020-11-13 Time 15:10 Rev Time 0.00
Received By ccole Date 2020-11-13 Time 14:03 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-11-02 Cont ID  
Sent By ccole Date 2020-11-02 Time 16:42 Rev Time 0.00
Received By ccole Date 2020-11-02 Time 15:59 Sent To  
Notes
2020-11-02 16:42:471ST REVIEW FBC-2017 RES. FUEL GAS
 PERMIT- 20100957
 11/2/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) GAS RISER DRAWING: PLEASE PROVIDE A COMPLETE RISER
 DRAWING THAT INCLUDES THE INTERIOR GAS APPLIANCES AND
 BRANCH PIPING INSTALLED UNDER PERMIT- 01030466 AND THE
 GAS GENERATOR INSTALLED UNDER PERMIT- 06040973. PERMIT-
 0130466 INDICATES A TOTAL LOAD OF 675,000 BTUH, AND
 PERMIT- 06040973 INDICATES A LOAD OF 550,000 BTUH FOR
 THE GENERATOR- SECTION 107.2.1 WPB AND SECTIONS G2412.3
 & G2412.4 FBC RES.
  
 A) SHOW THE CORRECT TOTAL LOAD AND THE INDIVIDUAL LOADS
 OF THE SYSTEM- SECTIONS G2412.3, G2412.4, & G2413.2 FBC
 RES.
  
 B) PROVIDE THE TOTAL LENGTH DEVELOPED LENGTH OF THE
 PIPING FROM THE METER TO THE MOST REMOTE OUTLET, AND
 THE INDIVIDUAL BRANCH LENGTHS- SECTIONS G2413.4.1 AND
 G2413.4.2 FBC RES.
  
 C) SHOW THE REQUIRED PIPE UNIONS FOR RIGID PIPING
 WITHIN 1 FT. OF EITHER SIDE THE REGULATOR- SECTION
 G2421.2(7) FBC RES.
  
 D) THE 1 IN. SCH 40 METALLIC PIPE IS UNDERSIZED FOR THE
 638,000 BTUH IS UNDERSIZED ACCORDING TO SIZING TABLE
 402.4(2) FBC FG THAT IS LISTED ON THE RISER.
  
 2) THE SURVEY SHOWS A 5 FT. CLEARANCE FROM THE
 GENERATOR EXHAUST TO OPENINGS INTO THE HOUSE HOWEVER A
 MINIMUM 10 FT. CLEARANCE IS REQUIRED TO MECHANICAL AND
 GRAVITY AIR INTAKES INTO THE BUILDING- SECTION-R303.5.1
 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-12-11 Cont ID  
Sent By jleahy Date 2020-12-11 Time 10:14 Rev Time 0.00
Received By jleahy Date 2020-11-12 Time 15:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-11-04 Cont ID  
Sent By rmcdouga Date 2020-11-04 Time 13:52 Rev Time 0.00
Received By rmcdouga Date 2020-10-23 Time 11:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2020-11-13 Cont ID  
Sent By ccole Date 2020-11-13 Time 15:10 Rev Time 0.00
Received By ccole Date 2020-11-13 Time 14:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-11-02 Cont ID  
Sent By ccole Date 2020-11-02 Time 16:43 Rev Time 0.00
Received By ccole Date 2020-11-02 Time 15:59 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-11-04 Cont ID  
Sent By rmcdouga Date 2020-11-04 Time 13:52 Rev Time 0.00
Received By rmcdouga Date 2020-11-04 Time 13:42 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2020-12-04 Cont ID  
Sent By kalexand Date 2020-12-04 Time 10:25 Rev Time 0.00
Received By kalexand Date 2020-12-04 Time 10:25 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2020-10-30 Cont ID  
Sent By aaponte Date 2020-10-30 Time 14:59 Rev Time 0.00
Received By kalexand Date 2020-10-30 Time 14:55 Sent To I
Notes
2020-10-30 15:36:45ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW:
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. INDICATE GENERATOR SETBACKS ON SURVEY
  
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD
 LIKE TO RESUBMIT ELECTRONICALLY, EMAIL
 [email protected] AND REQUEST TO HAVE YOUR
 PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG
 IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL.
 PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU
 ARE FINISHED UPLOADING.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 KIZZI ALEXANDRE, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1442
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved