Plan Review Stops For Permit 20100911 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-11-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-11-12 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-11-12 |
Time |
14:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-10-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-10-22 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-10-22 |
Time |
08:19 |
Sent To |
|
|
Notes |
2020-10-22 09:19:08 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE REVISION TO SHEET AE407 TO REPLACE THE WALL HUNG | | LAVATORIES WITH VANITIES IN RESTROOMS 268 AND 269 | | APPEARS TO CAUSE AN ISSUE. THE VANITIES APPEAR TO | | ENCROACH INTO THE REQUIRED MINIMUM 60" DIAMETER TURNING | | SPACE WITHOUT ALLOWING FOR KNEE AND TOE CLEARANCE. FBC | | ACCESSIBILITY 603 | | | | 2) THE REVISION TO SHEET AE404 IS TO REPLACE THE WALL | | HUNG LAVATORIES WITH VANITIES IN RESTROOMS E135 AND | | E136. SHOW THE REQUIRED CLEARANCES AT THE PLUMBING | | FIXTURES AND THE TURNING SPACE IN THE REVISED RESTROOMS | | ON SHEET AE404. FBC ACCESSIBILITY 603 | | | | 3) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | CITY RE-SUBMITTAL FORM. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-10-21 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-10-21 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-10-21 |
Time |
08:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2020-11-03 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-11-03 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-11-03 |
Time |
15:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2020-10-21 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-10-21 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-10-21 |
Time |
15:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2020-10-27 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-10-27 |
Time |
11:45 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-10-27 |
Time |
11:45 |
Sent To |
|
|
Notes |
2020-10-27 11:45:45 | 10/27/20 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-11-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-11-12 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-11-02 |
Time |
11:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-10-27 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-10-27 |
Time |
16:19 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-10-20 |
Time |
07:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2020-10-27 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-10-27 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-10-27 |
Time |
15:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2020-10-27 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-10-27 |
Time |
11:45 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-10-27 |
Time |
11:45 |
Sent To |
|
|
Notes |
2020-10-27 11:46:28 | 10/27/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-11-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-11-12 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-11-12 |
Time |
14:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-10-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-10-22 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-10-22 |
Time |
09:04 |
Sent To |
|
|
Notes |
2020-10-21 09:09:22 | ELECTRICAL PAGES OK FOR SIGNATURES JLEAHY |
|
|