Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-11-20 Cont ID  
Sent By pvalenti Date 2020-11-20 Time 13:09 Rev Time 0.00
Received By pvalenti Date 2020-11-20 Time 13:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-10-24 Cont ID  
Sent By pvalenti Date 2020-10-24 Time 10:53 Rev Time 0.00
Received By pvalenti Date 2020-10-24 Time 10:44 Sent To  
Notes
2020-10-24 10:54:52PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 1. FBC R 301, COMPLETE THE "SCHEDULE FOR INSTALLATION
 OF OPENING PROTECTIVE DEVICES" OR PROVIDE ALL
 INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS EXCEL
 SPREADSHEET):
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS?PAGE=2
  
 2. WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE
 NOTE FACTORS APPLY DEPENDING ON SUBSTRATE, EDGE
 DISTANCE AND FASTENER. FOR FASTENER, IF USING TAPCON,
 BE SPECIFIC AS TO WHICH TAPCON.
  
 PLEASE CONTACT ME IF YOU NEED ASSISTANCE.
  
 3. REVISE PLAN TO SHOW MEANS OF ESCAPE REQUIRED BY FBC
 R 310.4; INCLUDE ROOM DESIGNATION.
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-10-24 Cont ID  
Sent By pvalenti Date 2020-10-24 Time 10:55 Rev Time 0.00
Received By pvalenti Date 2020-10-23 Time 09:58 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET