Plan Review Stops For Permit 20100733 |
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
P |
Date |
2021-01-14 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-01-14 |
Time |
16:51 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-01-14 |
Time |
16:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
F |
Date |
2020-12-08 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-12-08 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-12-08 |
Time |
10:47 |
Sent To |
|
|
Notes |
2020-12-08 10:52:30 | 3RD REVIEW: CORRECTED PLANS WERE NOT SUBMITTED. SEE 2ND | | REVIEW COMMENTS BELOW. | | 12/8/2020 | | | | 2ND REVIEW FBC-2017 RES. FUEL GAS | | PERMIT- 20100733 | | 12/4/2020 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) BASED ON PIPE SIZING TABLE G2413.4(1) [402.4(2)] FBC | | RES. FUEL GAS THE 1/2 IN. SCHEDULE 40 GALVANIZED GAS | | PIPE IS UNDERSIZED TO SUPPLY THE 199,000 BTUH TANKLESS | | WATER HEATER. PLEASE PROVIDE A 3/4 IN. PIPE. | | | | 2) BASED ON PAGE 5 ON THE RHEEM WATER HEATER | | INSTALLATION MANUAL THE GAS INPUT PRESSURE RANGE IS | | 4.0- 10.5 IN. W.C. PLEASE PROVIDE A REGULATOR AT THE | | NEW WATER HEATER IN COMPLIANCE WITH SECTION G2421 FBC | | RES. SHOW THE MAKE AND MODEL OF THE REGULATOR ON THE | | PLAN AND SUBMIT SPECS MARKED UP OR HIGHLIGHTED TO THE | | SELECTED MODEL, INLET AND OUTLET PIPE SIZES AND | | PRESSURES, AND ORIFICE SIZE. SHOW THE REQUIRED PIPE | | UNIONS WITHIN 1 FT. OF EITHER SIDE OF THE REGULATOR- | | SECTION 2421.2(7) FBC RES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2020-12-04 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-12-04 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-12-04 |
Time |
09:18 |
Sent To |
|
|
Notes |
2020-12-04 09:55:20 | 2ND REVIEW FBC-2017 RES. FUEL GAS | | PERMIT- 20100733 | | 12/4/2020 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) BASED ON PIPE SIZING TABLE G2413.4(1) [402.4(2)] FBC | | RES. FUEL GAS THE 1/2 IN. SCHEDULE 40 GALVANIZED GAS | | PIPE IS UNDERSIZED TO SUPPLY THE 199,000 BTUH TANKLESS | | WATER HEATER. PLEASE PROVIDE A 3/4 IN. PIPE. | | | | 2) BASED ON PAGE 5 ON THE RHEEM WATER HEATER | | INSTALLATION MANUAL THE GAS INPUT PRESSURE RANGE IS | | 4.0- 10.5 IN. W.C. PLEASE PROVIDE A REGULATOR AT THE | | NEW WATER HEATER IN COMPLIANCE WITH SECTION G2421 FBC | | RES. SHOW THE MAKE AND MODEL OF THE REGULATOR ON THE | | PLAN AND SUBMIT SPECS MARKED UP OR HIGHLIGHTED TO THE | | SELECTED MODEL, INLET AND OUTLET PIPE SIZES AND | | PRESSURES, AND ORIFICE SIZE. SHOW THE REQUIRED PIPE | | UNIONS WITHIN 1 FT. OF EITHER SIDE OF THE REGULATOR- | | SECTION 2421.2(7) FBC RES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-11-03 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-11-03 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-11-03 |
Time |
09:34 |
Sent To |
|
|
Notes |
2020-11-03 10:46:52 | 1ST REVIEW FBC-2017 RES. FUEL GAS | | PERMIT- 20100733 | | 11/3/2020 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE PERMIT APPLICATION INDICATES THIS IS A WATER | | HEATER REPLACEMENT HOWEVER I WAS UNABLE TO FIND A | | PREVIOUS PERMIT ON FILE FOR EITHER A GAS-FIRED TANKLESS | | OR STORAGE TYPE WATER HEATER. PLEASE PROVIDE THE | | FOLLOWING ITEMS FOR PERMITTING: | | | | A) A BASIC FLOOR PLAN SHOWING LOCATION OF THE NEW | | TANKLESS WATER HEATER. IT IS NOT CLEAR IF THE UNIT WILL | | BE INSTALLED IN THE INTERIOR OR EXTERIOR- SECTION | | 107.2.1 WPB. INDICATE THE MODEL NUMBER ON THE PLAN. | | | | B) GAS RISER DRAWING THAT INCLUDES ALL NEW AND EXISTING | | APPLIANCES, EQUIPMENT, AND ALL NEW AND EXISTING GAS | | PIPING FROM THE METER TO THE MOST REMOTE OUTLET- | | SECTIONS G2412.3, G2412.4, & G2413.2 FBC RES. PLEASE | | INCLUDE THE TYPES AND SIZES OF PIPING, BRANCH AND CUT | | PIPING LENGTHS, THE TOTAL AND INDIVIDUAL GAS LOADS IN | | BTUH, TOTAL DEVELOPED LENGTH OF THE SYSTEM, DELIVERY | | PRESSURE AT THE METER, LOCATIONS OF REGULATORS AND | | OUTLET PRESSURES- SECTIONS G2413.1, G2413.3, G2413.4.1, | | G2413.4.2, G2421.1 & G2421.2 FBC RES. | | | | C) INDICATE ON THE RISER THE PIPE SIZING TABLE USED PER | | TABLES G2413.4(1)- G2413.4(8) FBC RES. | | | | D) COMBUSTION AND VENTING PLANS ARE REQUIRED FOR | | INTERIOR GAS WATER HEATERS. FOR EXTERIOR INSTALLATIONS | | PLEASE PROVIDE AN ELEVATION DRAWING SHOWING THE | | REQUIRED CLEARANCES FOR THE UNIT PER MANUFACTURER?S | | SPECIFICATIONS- SECTIONS G2407.1, G2426.2, G2426.7, & | | G2448.1 FBC RES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-01-14 |
Time |
|
Rev Time |
0.00 |
Received By |
ccarvaja |
Date |
2021-01-13 |
Time |
10:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-12-08 |
Time |
|
Rev Time |
0.00 |
Received By |
ccarvaja |
Date |
2020-12-04 |
Time |
15:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-12-04 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-12-01 |
Time |
09:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-11-03 |
Time |
|
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-10-22 |
Time |
15:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2021-01-14 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-01-14 |
Time |
16:51 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-01-14 |
Time |
16:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2020-12-08 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-12-08 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-12-08 |
Time |
10:47 |
Sent To |
|
|
Notes |
2020-12-08 10:50:51 | 3RD REVIEW: CORRECTED PLANS WERE NOT SUBMITTED. SEE 2ND | | REVIEW COMMENTS BELOW. | | 12/8/2020 | | | | 2ND REVIEW FBC-2017 RES. PLUMBING | | PERMIT- 20100733 | | 12/4/2020 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE REVISED PLAN SHOWS A NEW EXTERIOR TANKLESS WATER | | HEATER. PLEASE PROVIDE A WATER RISER SHOWING THE NEW | | PIPING CONNECTIONS TO THE EXISTING WATER DISTRIBUTION | | SYSTEM- SECTION 107.3.5.3 WPB. | | | | 2) 2ND REQUEST A PLUMBING SUB-PERMIT APPLICATION- | | SECTION 105.1 WPB. PLEASE NOTE THAT THE CITY OF WPB | | BUILDING DEPT. REQUIRES A PRIMARY GAS PERMIT FOR THE | | INSTALLATION AND A PLUMBING SUB-PERMIT. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2020-12-04 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-12-04 |
Time |
10:03 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-12-04 |
Time |
09:18 |
Sent To |
|
|
Notes |
2020-12-04 10:08:48 | 2ND REVIEW FBC-2017 RES. PLUMBING | | PERMIT- 20100733 | | 12/4/2020 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE REVISED PLAN SHOWS A NEW EXTERIOR TANKLESS WATER | | HEATER. PLEASE PROVIDE A WATER RISER SHOWING THE NEW | | PIPING CONNECTIONS TO THE EXISTING WATER DISTRIBUTION | | SYSTEM- SECTION 107.3.5.3 WPB. | | | | 2) 2ND REQUEST A PLUMBING SUB-PERMIT APPLICATION- | | SECTION 105.1 WPB. PLEASE NOTE THAT THE CITY OF WPB | | BUILDING DEPT. REQUIRES A PRIMARY GAS PERMIT FOR THE | | INSTALLATION AND A PLUMBING SUB-PERMIT. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-11-03 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-11-03 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-11-03 |
Time |
09:34 |
Sent To |
|
|
Notes |
2020-11-03 10:53:17 | 1ST REVIEW FBC-2017 RES. PLUMBING | | PERMIT- 20100733 | | 11/3/2020 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SUBMIT A PLUMBING SUB-PERMIT APPLICATION- SECTION | | 105.1 WPB. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2021-01-14 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-01-14 |
Time |
16:51 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-01-14 |
Time |
16:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2020-12-08 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-12-08 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-12-08 |
Time |
10:47 |
Sent To |
|
|
Notes |
2020-12-08 10:49:32 | 3RD REVIEW: CORRECTED PLANS WERE NOT SUBMITTED. SEE | | COMMENT FROM 2ND REVIEW BELOW. | | | | SIGNATURE REVIEW | | 12/4/2020 | | | | 1) THE CONTRACTOR OR QUALIFIER WHO PREPARED THE GAS | | RISER DRAWING SHALL PROVIDE HIS/HER SIGNATURE ON IT- | | SECTION 107.2.1 WPB, AND FLORIDA STATUTES 471.003(2)(H) | | & 471.025. PLEASE PROVIDE THE ADDRESS OF THE PROPERTY | | ON THE DRAWING. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2020-12-04 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-12-04 |
Time |
10:01 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-12-04 |
Time |
10:00 |
Sent To |
|
|
Notes |
2020-12-04 10:03:35 | SIGNATURE REVIEW | | 12/4/2020 | | | | 1) THE CONTRACTOR OR QUALIFIER WHO PREPARED THE GAS | | RISER DRAWING SHALL PROVIDE HIS/HER SIGNATURE ON IT- | | SECTION 107.2.1 WPB, AND FLORIDA STATUTES 471.003(2)(H) | | & 471.025. PLEASE PROVIDE THE ADDRESS OF THE PROPERTY | | ON THE DRAWING. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2020-11-03 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-11-03 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-11-03 |
Time |
09:34 |
Sent To |
|
|
Notes |
2020-11-03 10:49:23 | NO PLANS SUBMITTED. NEW PLANS WILL REQUIRE THE | | SIGNATURE, OR THE SIGNATURE AND SEAL OF THE OF THE PLAN | | DESIGNER- SECTION 107.2.1 WPB. |
|
|