Plan Review Details - Permit 20100675
Plan Review Stops For Permit 20100675
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2020-11-13 Cont ID  
Sent By jwitmer Date 2020-11-13 Time 15:32 Rev Time 0.00
Received By jwitmer Date 2020-11-13 Time 15:02 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-10-16 Cont ID  
Sent By jwitmer Date 2020-10-16 Time 20:02 Rev Time 0.00
Received By jwitmer Date 2020-10-16 Time 16:47 Sent To  
Notes
2020-10-16 20:03:48TO THE BUILDING CONTRACTOR:
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-11-13 Cont ID  
Sent By jwitmer Date 2020-11-13 Time 15:31 Rev Time 0.00
Received By jwitmer Date 2020-11-13 Time 15:02 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-10-16 Cont ID  
Sent By jwitmer Date 2020-10-16 Time 20:03 Rev Time 0.00
Received By jwitmer Date 2020-10-16 Time 16:47 Sent To  
Notes
2020-10-16 16:47:52WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20100675
 ADD: 2000 PRESIDENTIAL WAY # 501
 CONT: J&V RESIDENTIAL SERVICES
 TEL: 561-601-1614
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRI. OCT. 16TH/ 2020
 ACTION: DENIED
  
 1) SHEET A-1 THE DEMO FLOOR PLAN NOTES 4, 5 & 6 ALL
 QUOTE CODE SECTIONS 2017 FBC-B 1207.2 AIR-BORNE SOUND,
 1207.3 STRUCTURE-BORNE SOUND AND 603.1 EXCEPTION 2
 FLAME SPREAD.
  
 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.2.1. W.P.B.
 ADMINISTRATIVE CODE. DRAWINGS & SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC TO THE TECHNICAL CODES
 "CODE SECTIONS SHALL NOT BE CITED AS A WHOLE OR IN
 PART, NOR THE TERM "LEGAL" OR ITS EQUIVALENT BE USED AS
 A SUBSTITUTE FOR SPECIFIC INFORMATION". CONSTRUCTION
 DOCUMENTS SHALL BE SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED AND
 SHOW IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS
 OF THIS CODE AND RELEVANT LAWS, ORDINANCES, RULES AND
 REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL.
  
 2) FLOOR INSULATION (FBC-B 2017). FOR TILE, STONE,
 MARBLE, VINYL AND WOOD FLOORING ALL NEED TO HAVE HAD
 THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE
 FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS LISTED
 UNDER EACH OF THE STANDARDS FOR A 6 INCH CONCRETE FLOOR
 ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE ALL THREE TEST REPORTS SHOWING
 COMPLIANCE WITH:
 TYPE I AND II BUILDINGS
  
 2A) FBC-B 2017 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492.
  
 2B) FBC-B 2017 1207.2 AIR-BORNE SOUND. WALLS,
 PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR
 AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E
 90.
  
 2C) FLAME SPREAD- FBC-B 2017 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 3) BOTH SHEET A-2 & A-3 INDICATE THE REMOVAL OF A TUB
 AND CREATING A NEW SHOWER, THE PLANS DO NOT INDICATE
 HOW HIGH THE TILE WILL BE INSTALLED IN THE NEW SHOWER?
 SHOW COMPLIANCE WITH THE 2017 FBC-B SHOWERS & TUBS
 1210.3. SHOWER COMPARTMENTS AND BATHTUBS WITH INSTALLED
 SHOWER HEADS SHALL BE FINISHED WITH A NONABSORBENT
 SURFACE TO A HEIGHT NOT LESS THAN 72 INCHES ABOVE THE
 DRAIN INLET.
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-11-20 Cont ID  
Sent By equinone Date 2020-11-20 Time 14:37 Rev Time 0.00
Received By equinone Date 2020-11-20 Time 14:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-10-29 Cont ID  
Sent By equinone Date 2020-10-29 Time 16:04 Rev Time 0.00
Received By equinone Date 2020-10-29 Time 16:04 Sent To  
Notes
2020-10-29 16:09:44ENRIQUE QUINONEZ
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED,
 SEE COMMENTS BELOW
  
 ALL RECEPTACLES IN KITCHEN AREA MUST BE GFCI PROTECTED
 (NOT JUST THE COUNTER RECEPTACLES). NEC 210.8 (B)(2)

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-11-17 Cont ID  
Sent By pleduc Date 2020-11-17 Time   Rev Time 0.00
Received By pleduc Date 2020-11-17 Time 15:30 Sent To  
Notes
2020-11-17 15:30:41FIRE PROVISO:
  
 ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR
 CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR
 FIRE SPRINKLER SYSTEMS BY APPLICABLE LICENSED
 CONTRACTORS FOR CODE COVERAGE COMPLIANCE.
  
 ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE
 SPRINKLER SYSTEMS, INCLUDING DEMO, SHALL BE DONE UNDER
 SEPARATE PERMITS AND SHOP DRAWINGS.
  
 THE EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR
 FIRE SPRINKLER SHALL BE MAINTAINED AND REMAIN ACTIVE
 THROUGHOUT THE CONSTRUCTION PERIOD, INCLUDING DEMO.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-10-16 Cont ID  
Sent By pleduc Date 2020-10-16 Time   Rev Time 0.00
Received By pleduc Date 2020-10-16 Time 15:05 Sent To  
Notes
2020-10-16 15:09:01FIRE PROVISO:
  
 ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR
 CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR
 FIRE SPRINKLER SYSTEMS BY APPLICABLE LICENSED
 CONTRACTORS FOR CODE COVERAGE COMPLIANCE.
  
 ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE
 SPRINKLER SYSTEMS, INCLUDING DEMO, SHALL BE DONE UNDER
 SEPARATE PERMITS AND SHOP DRAWINGS.
  
 THE EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR
 FIRE SPRINKLER SHALL BE MAINTAINED AND REMAIN ACTIVE
 THROUGHOUT THE CONSTRUCTION PERIOD, INCLUDING DEMO.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-11-20 Cont ID  
Sent By equinone Date 2020-11-20 Time 14:39 Rev Time 0.00
Received By equinone Date 2020-11-10 Time 16:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-10-29 Cont ID  
Sent By jleahy Date 2020-10-29 Time 17:11 Rev Time 0.00
Received By jleahy Date 2020-10-14 Time 16:03 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-11-12 Cont ID  
Sent By medwards Date 2020-11-12 Time 10:50 Rev Time 0.00
Received By medwards Date 2020-11-12 Time 10:41 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-10-16 Cont ID  
Sent By medwards Date 2020-10-16 Time 15:06 Rev Time 0.00
Received By medwards Date 2020-10-16 Time 15:01 Sent To  
Notes
2020-10-16 15:08:46MOVING OF THE DRYER TO A NEW LOCATION WILL REQUIRE A
 MECHANICAL PERMIT FOR RUNNING THE DRYER DUCT TO THE NEW
 LOCATION. PLEASE SHOW NEW DRYER DUCT AT THE NEW
 LOCATION. PROVIDE LENGTH OF THE ENTIRE DRYER DUCT AND
 THE TERMINATION POINT. FBC M 504.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-11-13 Cont ID  
Sent By ccole Date 2020-11-13 Time 10:35 Rev Time 0.00
Received By ccole Date 2020-11-13 Time 10:35 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-10-22 Cont ID  
Sent By ccole Date 2020-10-22 Time 16:55 Rev Time 0.00
Received By ccole Date 2020-10-22 Time 15:53 Sent To  
Notes
2020-10-22 16:59:221ST REVIEW FBC-2017 PLUMBING
 PERMIT- 20100675
 10/22/2020
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A-3: THE 2 IN. WASHING MACHINE STANDPIPE DRAIN
 SHALL CONNECT TO A 3 IN. STACK OR HORIZONTAL BRANCH
 DRAIN- SECTION 406.2 FBC P.
  
 2) A-3 SHOWER DETAIL: SHOW AN APPROVED PAN LINER WILL
 BE INSTALLED IN ACCORDANCE WITH SECTIONS 417.5.2-
 417.5.2.6 FBC P, AND INDICATE IT WILL BE SLOPED TO THE
 DRAIN AT A PITCH OF 1/4 IN PER FT.
  
 3) A-2 & A-3: PLEASE PLACE A NOTE TO CLARIFY IF THE TUB
 DRAIN WILL BE RELOCATED FOR THE NEW SHOWER OR IF IT
 WILL REMAIN IN THE SAME LOCATION. A SANITARY RISER IS
 REQUIRED FOR RELOCATED DRAINS AND VENTS- SECTIONS 701.1
 AND 901.1 FBC P.
  
 4) A-2 & A-3: PLACE A NOTE TO INDICATE THE NEW SHOWER
 VALVE SHALL MEET COMPLIANCE WITH SECTION 424.3 FBC P
 AND SHALL BE BALANCED-PRESSURE, THERMOSTATIC OR
 COMBINATION BALANCED-PRESSURE/THERMOSTATIC VALVES THAT
 CONFORM TO THE REQUIREMENTS OF ASSE 1016/ASME
 A112.1016/CSA B125.16 OR ASME A112.18.1/CSA B125.1.
  
 5) A-2 & A-3: SHOW THE LOCATIONS OF THE NEW WASHING
 MACHINE VALVES AND PLACE A NOTE SHOWING IT WILL BE
 INSTALLED IN AN ACCESSIBLE LOCATION- SECTION 606.3 FBC
 P.
  
 6) A-2 & A-3: PROVIDE A WATER RISER DRAWING FOR THE
 WASHING MACHINE SHOWING SUPPLY PIPING, REQUIRED WATER
 HAMMER ARRESTORS, AND POINTS OF CONNECTION TO THE
 EXISTING WATER LINES- SECTION 604.9 FBC P. AS AN
 ALTERNATE TO A RISER DRAWING, NOTES ON THE PLAN ARE
 ACCEPTABLE.
  
 7) A-2 & A-3: PROVIDE A SLAB REPAIR DETAIL- SECTION
 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-11-12 Cont ID  
Sent By equinone Date 2020-11-12 Time 09:50 Rev Time 0.00
Received By equinone Date 2020-11-12 Time 09:50 Sent To  
Notes
2020-11-12 09:51:40PAPER DRAWINGS HAVE ORIGINAL SEAL AND SIGNATURE. ROUTED
 TO STORAGE. EQ

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-10-16 Cont ID  
Sent By equinone Date 2020-10-16 Time 13:13 Rev Time 0.00
Received By equinone Date 2020-10-16 Time 13:13 Sent To  
Notes
***NONE***