Plan Review Stops For Permit 20100670 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
P |
Date |
2020-11-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-11-23 |
Time |
16:37 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2020-11-02 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-11-02 |
Time |
09:22 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-11-02 |
Time |
08:22 |
Sent To |
|
|
Notes |
2020-11-02 09:22:20 | COMMERCIAL ASBESTOS | | | | TO THE BUILDING CONTRACTOR: | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2020-11-02 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-11-02 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-11-02 |
Time |
08:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-11-16 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2020-11-16 |
Time |
12:34 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2020-11-16 |
Time |
12:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2020-10-27 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-10-27 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-10-23 |
Time |
14:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-11-24 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-11-24 |
Time |
06:46 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-11-18 |
Time |
12:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-11-16 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2020-11-16 |
Time |
12:34 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2020-10-16 |
Time |
07:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2020-11-24 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-11-24 |
Time |
06:43 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-11-24 |
Time |
06:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-11-04 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-11-04 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-11-04 |
Time |
13:57 |
Sent To |
|
|
Notes |
2020-11-04 14:49:22 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT-20100670 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE INDICATE THE SIZE OF EACH NEW DUCT SERVING | | THE NEW OFFICES. FBC 107.3.5 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2020-10-29 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-10-29 |
Time |
17:00 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-10-29 |
Time |
16:09 |
Sent To |
|
|
Notes |
2020-10-29 17:02:37 | PLUMBING PLANS NOT INCLUDED IN THE PLAN SET, NO | | PLUMBING WORK SHOWN ON THE SUBMITTED PLANS. | | A SEPARATE PERMIT IS REQUIRED FOR PLUMBING DEMOLITION | | AND ALTERATIONS. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-11-24 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-11-24 |
Time |
06:46 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-11-24 |
Time |
06:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-11-16 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2020-10-20 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2020-10-20 |
Time |
16:13 |
Sent To |
|
|
Notes |
|
|