Plan Review Stops For Permit 20100620 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-11-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-25 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-25 |
Time |
14:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-11-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-23 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-23 |
Time |
14:04 |
Sent To |
|
|
Notes |
2020-11-23 14:06:01 | PLAN REVIEW / BUILDING / GENERATOR | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | RE: PRE-CAST GENERATOR PAD ENGINEERING | | | | 1.PROVIDE SITE SPECIFIC WIND LOAD DESIGN PRESSURE | | CALCULATIONS FOR USE WITH THIS SYSTEM. (SEE EOR NOTE) | | SITE SPECIFIC LOAD REQUIREMENTS SHALL BE LESS THAN OR | | EQUAL TO THE POSITIVE OR NEGATIVE DESIGN PRESSURE | | CAPACITY LISTED | | IN THE CONCRETE PAD SCHEDULE. | | | | FBC 107.3.5.1.1(8) ? PROVIDE WIND DESIGN LOADS/DESIGN | | PRESSURES PURSUANT TO FBC-CHAPTER 16 | | 1603.1.4 WIND DESIGN DATA. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-11-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-06 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-06 |
Time |
15:01 |
Sent To |
|
|
Notes |
2020-11-06 15:27:11 | PLAN REVIEW GENERATOR / BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1) PROVIDE STRUCTURAL DETAIL OF GENERATOR PAD. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | 2) STRUCTURAL PAD DETAIL SHALL BE SIGNED BY DESIGNER. | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | 481, F.S. & 61G1. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-11-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-06 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-06 |
Time |
15:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2020-11-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-11-05 |
Time |
12:04 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-11-05 |
Time |
11:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-11-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-25 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-24 |
Time |
16:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-11-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-23 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-17 |
Time |
16:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-11-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-06 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-02 |
Time |
16:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2020-11-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-11-05 |
Time |
12:04 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-11-05 |
Time |
11:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2020-11-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-25 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-25 |
Time |
14:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2020-11-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-23 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-23 |
Time |
14:04 |
Sent To |
|
|
Notes |
2020-11-23 14:06:52 | PLAN REVIEW / SIGNATURES | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | RE: PRE-CAST GENERATOR PAD ENGINEERING | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | SIGNATURE. | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | WET SEAL AND SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-11-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-06 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-06 |
Time |
15:01 |
Sent To |
|
|
Notes |
2020-11-06 15:30:13 | PLAN REVIEW GENERATOR / SIGNATURES | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | STRUCTURAL DETAIL OF GENERATOR PAD REQUIRED. NEW | | SIGNATURE REVIEW REQUIRED. | | | | 1) STRUCTURAL PAD DETAIL SHALL BE SIGNED BY DESIGNER. | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | 481, F.S. & 61G1. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2020-11-05 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-11-05 |
Time |
|
Rev Time |
|
Received By |
rthermid |
Date |
2020-11-05 |
Time |
|
Sent To |
I |
|
Notes |
|
|