Plan Review Details - Permit 20100256
Plan Review Stops For Permit 20100256
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2020-10-16 Cont ID  
Sent By cpuell Date 2020-10-16 Time 15:26 Rev Time 0.00
Received By cpuell Date 2020-10-16 Time 15:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-11-16 Cont ID  
Sent By rmcphers Date 2020-11-13 Time 10:18 Rev Time 0.00
Received By rmcphers Date 2020-11-13 Time 10:18 Sent To  
Notes
2020-11-13 10:20:15 
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-10-28 Cont ID  
Sent By rmcphers Date 2020-10-28 Time 13:35 Rev Time 0.00
Received By rmcphers Date 2020-10-28 Time 11:22 Sent To  
Notes
2020-10-28 13:35:38NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW THE 1ST FLOOR TOILET ROOM DOOR TO COMPLY
 WITH FBC R320.1.1
 ALL NEW SINGLE-FAMILY HOUSES, DUPLEXES, TRIPLEXES,
 CONDOMINIUMS AND TOWNHOUSES SHALL PROVIDE AT LEAST ONE
 BATHROOM, LOCATED WITH MAXIMUM POSSIBLE PRIVACY, WHERE
 BATHROOMS ARE PROVIDED ON HABITABLE GRADE LEVELS, WITH
 A DOOR THAT HAS A 29-INCH (737 MM) CLEAR OPENING.
 HOWEVER, IF ONLY A TOILET ROOM IS PROVIDED AT GRADE
 LEVEL, SUCH TOILET ROOMS SHALL HAVE A CLEAR OPENING OF
 NOT LESS THAN 29 INCHES (737 MM).-- FBC A 404.2.3 CLEAR
 WIDTH. CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS
 SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE
 STOP, WITH THE DOOR OPEN 90 DEGREES.
 2) PLEASE SHOW THE DOOR FROM THE GARAGE TO THE LIVING
 SPACE TO COMPLY WITH FBC R302.5.1 OPENING PROTECTION.
 OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE
 EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 13/8
 INCHES (35 MM) IN THICKNESS, SOLID OR HONEYCOMB-CORE
 STEEL DOORS NOT LESS THAN 13/8 INCHES (35 MM) THICK, OR
 20-MINUTE FIRE-RATED DOORS.
 3) PLEASE SHOW THE REQUIREMENT OF "TYPE X" DRYWALL FOR
 THE GARAGE CEILING - FBC R302.6
 4) PLEASE SHOW THE DRAFT STOPPING AT THE FLOOR FRAMING
 TO COMPLY WITH FBC R302.12 DRAFTSTOPPING.IN COMBUSTIBLE
 CONSTRUCTION WHERE THERE IS USABLE SPACE BOTH ABOVE AND
 BELOW THE CONCEALED SPACE OF A FLOOR-CEILING ASSEMBLY,
 DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE
 CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FEET (92.9
 M2). DRAFTSTOPPING SHALL DIVIDE THE CONCEALED SPACE
 INTO APPROXIMATELY EQUAL AREAS.
 5) DRAWINGS NEED TO BE SIGNED AND SEALED BY THE
 ENGINEER. (ELECTRONICALLY SIGNED TO BE USED IN
 PROJECTDOX ELECTRONIC PLAN REVIEW)

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-11-04 Cont ID  
Sent By fgiaquin Date 2020-11-04 Time 20:29 Rev Time 0.00
Received By fgiaquin Date 2020-11-04 Time 19:50 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-10-29 Cont ID  
Sent By fgiaquin Date 2020-10-29 Time 22:24 Rev Time 0.00
Received By fgiaquin Date 2020-10-29 Time 21:35 Sent To  
Notes
2020-10-29 21:49:11ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. FAULT CURRENT AT FPL TRANSFORMER SECONDARY IS
 21200AMPS PER FAULT CURRENT LETTER. NOTE ON PLAN STATES
 ALL EQUIPMENT WILL BE RATED AT 10,000 AIC. PROVIDE
 FAULT CURRENT CALCULATION SHOWING FAULT CURRENT RATING
 FROM SECONDARY OF TRANSFORMER TO SERVICE ENTRANCE
 EQUIPMENT. NEC 110.10 FBC 107.2.1
  
 2. SMOKE/CARBON ALARM IN KITCHEN MUST BE ATLEAST 10'
 AWAY FROM NEAREST COOKING APPLIANCE. NEC 110.3B PROVIDE
 CORRECTION.
  
 3. BALCONIES ON SECOND FLOOR ARE MISSING REQUIRED
 RECEPTACLE OUTLETS NEC 210.52E3
  
 4. TAMPERPROOF RECEPTACLES ARE REQUIRED PER NEC 406.12
 PROVIDE CORRECTION. A NOTE ON PLAN WILL SUFFICE.
  
 5. NOTE ON RISER DIAGRAM SAYS "1/0 TO GROUND RODS THEN
 CW PIPE" BUT DIAGRAM SHOWS #4. PROVIDE CORRECTION. #4
 IS ALL THATS REQUIRED FOR GROUND RODS, CW PIPE, AND
 BUILDING STEEL FYI.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-657-1653
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2020-10-27 Cont ID  
Sent By lcrespo Date 2020-10-27 Time 12:14 Rev Time 0.00
Received By lcrespo Date 2020-10-27 Time 12:14 Sent To  
Notes
2020-10-27 12:15:09GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN
 THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN
 PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS
 WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE
 RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT
 REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER
 THE WPB AMENDMENTS TO FBC SEC. 107.2.1.
  
 A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR
 FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC
 SEC. 105.1.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-11-13 Cont ID  
Sent By rmcphers Date 2020-11-13 Time 10:21 Rev Time 0.00
Received By rmcphers Date 2020-11-03 Time 08:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-10-29 Cont ID  
Sent By fgiaquin Date 2020-10-29 Time 22:28 Rev Time 0.00
Received By fgiaquin Date 2020-10-15 Time 16:18 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2020-12-03 Cont ID  
Sent By lmarchan Date 2020-12-03 Time 12:01 Rev Time 0.00
Received By lmarchan Date 2020-11-17 Time 15:00 Sent To  
Notes
2020-12-01 14:24:23RECEIPT MU-2020-46445 - $2430.79 - PAID
2020-11-17 15:00:5411/17/20 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-10-28 Cont ID  
Sent By rmcphers Date 2020-10-28 Time 13:36 Rev Time 0.00
Received By rmcphers Date 2020-10-28 Time 13:36 Sent To  
Notes
2020-10-28 13:37:10PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-11-04 Cont ID  
Sent By medwards Date 2020-11-04 Time 13:39 Rev Time 0.00
Received By medwards Date 2020-11-04 Time 13:39 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-10-27 Cont ID  
Sent By medwards Date 2020-10-27 Time 10:55 Rev Time 0.00
Received By medwards Date 2020-10-27 Time 10:02 Sent To  
Notes
2020-10-27 10:55:061ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20100256
  
 CODES IN EFFECT:
  
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET AC-1: IT APPEARS THAT THE AC-1 IS LOCATED
 INSIDE OF THE GARAGE. DUCTS IN THE GARAGE AND DUCTS
 PENETRATING THE WALLS OR CEILINGS SEPARATING THE
 DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A
 MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL, 1 INCH (25.4
 MM) MINIMUM RIGID NONMETALLIC CLASS 0 OR CLASS 1 DUCT
 BOARD, OR OTHER APPROVED MATERIAL AND SHALL NOT HAVE
 OPENINGS INTO THE GARAGE. FBC RES R302.5.2
  
 2) SHEET AC-1: PLEASE SHOW THE DRYER DUCT MATERIAL AND
 THE TERMINATION LOCATION. FBC RES M1502.3
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-11-04 Cont ID  
Sent By lcrespo Date 2020-11-04 Time 14:12 Rev Time 0.00
Received By lcrespo Date 2020-11-04 Time 14:04 Sent To  
Notes
2020-11-04 14:12:4311/04/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2020-10-27 Cont ID  
Sent By lcrespo Date 2020-10-27 Time 12:15 Rev Time 0.00
Received By lcrespo Date 2020-10-27 Time 11:50 Sent To  
Notes
2020-10-27 12:15:3810/27/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2020-10-28 Cont ID  
Sent By rmcphers Date 2020-10-28 Time 13:37 Rev Time 0.00
Received By rmcphers Date 2020-10-28 Time 13:37 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-11-13 Cont ID  
Sent By rmcphers Date 2020-11-13 Time 10:20 Rev Time 0.00
Received By rmcphers Date 2020-11-13 Time 10:20 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-10-28 Cont ID  
Sent By rmcphers Date 2020-10-28 Time 13:37 Rev Time 0.00
Received By rmcphers Date 2020-10-28 Time 13:37 Sent To  
Notes
2020-10-28 13:39:01SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW.
 DRAWINGS DO NOT SHOW IN "ADOBE READER" AS
 DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR
 ARCHITECT OR ENGINEER DOES NOT HAVE AN ELECTRONIC OR
 DIGITAL SIGNATURE - PLEASE DROP OFF (CITY HALL DROP
 BOX) THE ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS
 ALONG WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE
 REASON FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN
 REVIEW REQUEST FORM CAN BE OBTAINED BY E MAILING
 [email protected] AND ASKING FOR THE FORM.

Review Stop Z ZONING
Rev No 2 Status P Date 2020-11-12 Cont ID  
Sent By rthermid Date 2020-11-17 Time   Rev Time 0.00
Received By rthermid Date 2020-11-12 Time   Sent To I
Notes
2020-11-12 09:51:56NO NOTES

Review Stop Z ZONING
Rev No 1 Status F Date 2020-10-27 Cont ID  
Sent By rthermid Date 2020-10-27 Time   Rev Time  
Received By rthermid Date 2020-10-27 Time   Sent To I
Notes
2020-10-27 10:02:41ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 10/27/2020
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. THE REQUIRED FRONT SETBACK IS 25 FEET. THE PROPOSED
 FRONT SETBACK IS (+ -) 19 FEET.
 2. THE REQUIRED REAR SETBACK IS 15 FEET OR 10% OF THE
 LOT DEPTH. THE LOT DEPTH IS 100 FEET. THE REQUIRED REAR
 SETBACK IS THEN 10 FEET MINIMUM.
 3. MECHANICAL EQUIPMENT CANNOT ENCROACH MORE THAN 4
 FEET INTO A REQUIRED SETBACK. THE REQUIRED SIDE SETBACK
 IS 5 FEET, THIS MEANS THE PROPOSED MECHANICAL EQUIPMENT
 (GENERATORS, AC EQUIPMENT ETC) MUST BE SETBACK A
 MINIMUM OF 1 FOOT (12") FROM THE SIDE PROPERTY LINE.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD
 LIKE TO RESUBMIT ELECTRONICALY, EMAIL
 [email protected] AND REQUEST TO HAVE YOUR
 PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOGIN
 INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL.
 PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU
 ARE FINISHED UPLOADING.
  
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 RAFAELA THERMIDOR, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 TTY: 800.955.8771
 E: [email protected]
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved