Plan Review Stops For Permit 20100256 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2020-10-16 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-10-16 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-10-16 |
Time |
15:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-11-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-11-13 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-11-13 |
Time |
10:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-10-28 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-10-28 |
Time |
13:35 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-10-28 |
Time |
11:22 |
Sent To |
|
|
Notes |
2020-10-28 13:35:38 | NEW SFR | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE SHOW THE 1ST FLOOR TOILET ROOM DOOR TO COMPLY | | WITH FBC R320.1.1 | | ALL NEW SINGLE-FAMILY HOUSES, DUPLEXES, TRIPLEXES, | | CONDOMINIUMS AND TOWNHOUSES SHALL PROVIDE AT LEAST ONE | | BATHROOM, LOCATED WITH MAXIMUM POSSIBLE PRIVACY, WHERE | | BATHROOMS ARE PROVIDED ON HABITABLE GRADE LEVELS, WITH | | A DOOR THAT HAS A 29-INCH (737 MM) CLEAR OPENING. | | HOWEVER, IF ONLY A TOILET ROOM IS PROVIDED AT GRADE | | LEVEL, SUCH TOILET ROOMS SHALL HAVE A CLEAR OPENING OF | | NOT LESS THAN 29 INCHES (737 MM).-- FBC A 404.2.3 CLEAR | | WIDTH. CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS | | SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE | | STOP, WITH THE DOOR OPEN 90 DEGREES. | | 2) PLEASE SHOW THE DOOR FROM THE GARAGE TO THE LIVING | | SPACE TO COMPLY WITH FBC R302.5.1 OPENING PROTECTION. | | OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE | | EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 13/8 | | INCHES (35 MM) IN THICKNESS, SOLID OR HONEYCOMB-CORE | | STEEL DOORS NOT LESS THAN 13/8 INCHES (35 MM) THICK, OR | | 20-MINUTE FIRE-RATED DOORS. | | 3) PLEASE SHOW THE REQUIREMENT OF "TYPE X" DRYWALL FOR | | THE GARAGE CEILING - FBC R302.6 | | 4) PLEASE SHOW THE DRAFT STOPPING AT THE FLOOR FRAMING | | TO COMPLY WITH FBC R302.12 DRAFTSTOPPING.IN COMBUSTIBLE | | CONSTRUCTION WHERE THERE IS USABLE SPACE BOTH ABOVE AND | | BELOW THE CONCEALED SPACE OF A FLOOR-CEILING ASSEMBLY, | | DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE | | CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FEET (92.9 | | M2). DRAFTSTOPPING SHALL DIVIDE THE CONCEALED SPACE | | INTO APPROXIMATELY EQUAL AREAS. | | 5) DRAWINGS NEED TO BE SIGNED AND SEALED BY THE | | ENGINEER. (ELECTRONICALLY SIGNED TO BE USED IN | | PROJECTDOX ELECTRONIC PLAN REVIEW) |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-11-04 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2020-11-04 |
Time |
20:29 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2020-11-04 |
Time |
19:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-10-29 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2020-10-29 |
Time |
22:24 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2020-10-29 |
Time |
21:35 |
Sent To |
|
|
Notes |
2020-10-29 21:49:11 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. FAULT CURRENT AT FPL TRANSFORMER SECONDARY IS | | 21200AMPS PER FAULT CURRENT LETTER. NOTE ON PLAN STATES | | ALL EQUIPMENT WILL BE RATED AT 10,000 AIC. PROVIDE | | FAULT CURRENT CALCULATION SHOWING FAULT CURRENT RATING | | FROM SECONDARY OF TRANSFORMER TO SERVICE ENTRANCE | | EQUIPMENT. NEC 110.10 FBC 107.2.1 | | | | 2. SMOKE/CARBON ALARM IN KITCHEN MUST BE ATLEAST 10' | | AWAY FROM NEAREST COOKING APPLIANCE. NEC 110.3B PROVIDE | | CORRECTION. | | | | 3. BALCONIES ON SECOND FLOOR ARE MISSING REQUIRED | | RECEPTACLE OUTLETS NEC 210.52E3 | | | | 4. TAMPERPROOF RECEPTACLES ARE REQUIRED PER NEC 406.12 | | PROVIDE CORRECTION. A NOTE ON PLAN WILL SUFFICE. | | | | 5. NOTE ON RISER DIAGRAM SAYS "1/0 TO GROUND RODS THEN | | CW PIPE" BUT DIAGRAM SHOWS #4. PROVIDE CORRECTION. #4 | | IS ALL THATS REQUIRED FOR GROUND RODS, CW PIPE, AND | | BUILDING STEEL FYI. | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-657-1653 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2020-10-27 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-10-27 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-10-27 |
Time |
12:14 |
Sent To |
|
|
Notes |
2020-10-27 12:15:09 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR | | FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC | | SEC. 105.1. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-11-13 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-11-13 |
Time |
10:21 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-11-03 |
Time |
08:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-10-29 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2020-10-29 |
Time |
22:28 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2020-10-15 |
Time |
16:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2020-12-03 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-12-03 |
Time |
12:01 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-11-17 |
Time |
15:00 |
Sent To |
|
|
Notes |
2020-12-01 14:24:23 | RECEIPT MU-2020-46445 - $2430.79 - PAID | 2020-11-17 15:00:54 | 11/17/20 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2020-10-28 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-10-28 |
Time |
13:36 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-10-28 |
Time |
13:36 |
Sent To |
|
|
Notes |
2020-10-28 13:37:10 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2020-11-04 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-11-04 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-11-04 |
Time |
13:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-10-27 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-10-27 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-10-27 |
Time |
10:02 |
Sent To |
|
|
Notes |
2020-10-27 10:55:06 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT-20100256 | | | | CODES IN EFFECT: | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET AC-1: IT APPEARS THAT THE AC-1 IS LOCATED | | INSIDE OF THE GARAGE. DUCTS IN THE GARAGE AND DUCTS | | PENETRATING THE WALLS OR CEILINGS SEPARATING THE | | DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A | | MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL, 1 INCH (25.4 | | MM) MINIMUM RIGID NONMETALLIC CLASS 0 OR CLASS 1 DUCT | | BOARD, OR OTHER APPROVED MATERIAL AND SHALL NOT HAVE | | OPENINGS INTO THE GARAGE. FBC RES R302.5.2 | | | | 2) SHEET AC-1: PLEASE SHOW THE DRYER DUCT MATERIAL AND | | THE TERMINATION LOCATION. FBC RES M1502.3 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2020-11-04 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-11-04 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-11-04 |
Time |
14:04 |
Sent To |
|
|
Notes |
2020-11-04 14:12:43 | 11/04/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2020-10-27 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-10-27 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-10-27 |
Time |
11:50 |
Sent To |
|
|
Notes |
2020-10-27 12:15:38 | 10/27/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2020-10-28 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-10-28 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-10-28 |
Time |
13:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-11-13 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-11-13 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-11-13 |
Time |
10:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-10-28 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-10-28 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-10-28 |
Time |
13:37 |
Sent To |
|
|
Notes |
2020-10-28 13:39:01 | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | ARCHITECT OR ENGINEER DOES NOT HAVE AN ELECTRONIC OR | | DIGITAL SIGNATURE - PLEASE DROP OFF (CITY HALL DROP | | BOX) THE ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS | | ALONG WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE | | REASON FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN | | REVIEW REQUEST FORM CAN BE OBTAINED BY E MAILING | | [email protected] AND ASKING FOR THE FORM. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2020-11-12 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-11-17 |
Time |
|
Rev Time |
0.00 |
Received By |
rthermid |
Date |
2020-11-12 |
Time |
|
Sent To |
I |
|
Notes |
2020-11-12 09:51:56 | NO NOTES |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-10-27 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-10-27 |
Time |
|
Rev Time |
|
Received By |
rthermid |
Date |
2020-10-27 |
Time |
|
Sent To |
I |
|
Notes |
2020-10-27 10:02:41 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: 10/27/2020 | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. THE REQUIRED FRONT SETBACK IS 25 FEET. THE PROPOSED | | FRONT SETBACK IS (+ -) 19 FEET. | | 2. THE REQUIRED REAR SETBACK IS 15 FEET OR 10% OF THE | | LOT DEPTH. THE LOT DEPTH IS 100 FEET. THE REQUIRED REAR | | SETBACK IS THEN 10 FEET MINIMUM. | | 3. MECHANICAL EQUIPMENT CANNOT ENCROACH MORE THAN 4 | | FEET INTO A REQUIRED SETBACK. THE REQUIRED SIDE SETBACK | | IS 5 FEET, THIS MEANS THE PROPOSED MECHANICAL EQUIPMENT | | (GENERATORS, AC EQUIPMENT ETC) MUST BE SETBACK A | | MINIMUM OF 1 FOOT (12") FROM THE SIDE PROPERTY LINE. | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | LIKE TO RESUBMIT ELECTRONICALY, EMAIL | | [email protected] AND REQUEST TO HAVE YOUR | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOGIN | | INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | ARE FINISHED UPLOADING. | | | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | TTY: 800.955.8771 | | E: [email protected] | | W: WPB.ORG | | |
|
|