Plan Review Details - Permit 20100213
Plan Review Stops For Permit 20100213
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-10-19 Cont ID  
Sent By rmcdouga Date 2020-10-19 Time 09:46 Rev Time 0.00
Received By rmcdouga Date 2020-10-19 Time 08:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-10-14 Cont ID  
Sent By jleahy Date 2020-10-14 Time 14:06 Rev Time 0.00
Received By jleahy Date 2020-10-14 Time 14:02 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-10-08 Cont ID  
Sent By pleduc Date 2020-10-08 Time   Rev Time 0.00
Received By pleduc Date 2020-10-07 Time 14:26 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2020-11-16 Cont ID  
Sent By ccole Date 2020-11-16 Time 14:50 Rev Time 0.00
Received By ccole Date 2020-11-13 Time 08:53 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-10-21 Cont ID  
Sent By ccole Date 2020-10-21 Time 14:36 Rev Time 0.00
Received By ccole Date 2020-10-06 Time 17:29 Sent To  
Notes
2020-10-21 14:37:041ST REVIEW FBC-2014 FUEL GAS
 REVISION PERMIT- 20100213
 MASTER PERMIT- 17121049
 10/20/2020
  
 CODES IN EFFECT:
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2014
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2014
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2014
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2014
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2014
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2014
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2014
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2014
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS P201 & P202: THE WOK (107.1) IS NOT SHOWN IN
 THE RISER. PLEASE ADD IT TO THE RISER AND CORRECT THE
 TOTAL 1,190 MBTU SHOWN AT THE METER. IT WOULD BE
 HELPFUL TO SHOW THE INDIVIDUAL LOADS FOR THE COOKING
 LINE APPLIANCES IN THE DRAWING- SECTIONS 402.2 FBC FG.
  
 2) SHOW THE DELIVERY PRESSURE AT THE METER, WHICH
 APPEARS TO BE 2 PSI, AND THE LOCATIONS OF STEP DOWN
 REGULATORS FOR REDUCING PRESSURES TO THE WATER HEATERS
 AND COOKING LINE APPLIANCES- SECTION 410.1 & 410.2.
 PLEASE INDICATE THE REQUIRED PIPE UNIONS WITHIN 1 FT.
 OF EITHER SIDE OF THE REGULATORS- SECTION 410.2(7).
 PLEASE IDENTIFY THE MAKES AND MODELS OF THE REGULATORS
 ON THE PLAN AND/OR SUBMIT MARKED UP OR HIGHLIGHTED
 SPECS FOR THE REGULATOR SHOWING THE SELECTED MODELS,
 THE MAX INLET AND OUTLET SIZE AND PRESSURES, SPRING
 DATA, AND ORIFICE SIZES- SECTION 410.
  
 3) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE COOKING
 APPLIANCES AND WATER HEATERS- SECTIONS 623.1 & 624.1.
  
 4) AN AUTOMATIC GAS SHUTOFF VALVE IS REQUIRED TO BE
 CONNECTED TO THE HOOD FIRE SUPPRESSION SYSTEM PER
 SEC.10.4.1 NFPA 96. PLEASE SHOW THE LOCATION OF THE
 VALVE ON THE RISER DRAWING.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 CCOLE@WPB
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2020-11-16 Time   Rev Time 0.00
Received By lmarchan Date 2020-11-10 Time 14:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-10-21 Time   Rev Time 0.00
Received By lmarchan Date 2020-10-05 Time 16:07 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-11-12 Cont ID  
Sent By medwards Date 2020-11-12 Time 10:27 Rev Time 0.00
Received By medwards Date 2020-11-12 Time 09:02 Sent To  
Notes
2020-11-12 10:30:07MECHANICAL SYSEMS FOR CONDITIONED SPACE APPROVED.
 ALL OF THE REVISIONS BEING DONE TO THE HOODS AND GREASE
 DUCT MUST BE SUBMITTED UNDER THE HOOD PERMIT FOR
 REVIEW. FBC 107.2
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-10-06 Cont ID  
Sent By medwards Date 2020-10-06 Time 15:36 Rev Time 0.00
Received By medwards Date 2020-10-06 Time 14:39 Sent To  
Notes
2020-10-06 15:37:221ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20100213
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE A SCOPE OF WORK FOR THE MECHANICAL
 CHANGES. FBC 107.2.1
  
 2) PLEASE SUBMIT A COPY OF THE APPROVED PLANS ALONG
 WITH THE REVISED DRAWINGS TO COMPARE THE CHANGES. FBC
 107.2.1
  
 3) PLEASE PROVIDE THE APPLICATION/REVISION # ON THE
 PLAN REVIEW REQUEST FORM. FBC 107.2.1
  
 4) PLEASE REMOVE ALL LAYERS FROM REVISED DRAWING THAT
 DO NOT PERTAIN TO THE MECHANICAL SYSTEMS TO SHOW THE
 CHANGES MORE CLEARLY.
  
 5) PLEASE CLOUD ONLY THE REVISIONS ON THE DRAWINGS. FBC
 107.2.1
  
 6) IT APPEARS THAT YOU HAVE ADDED A KITCHEN HOOD,
 PLEASE PROVIDE A NEW AIR BALANCE SCHEDULE. FBC M
 508.1.2
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-11-16 Cont ID  
Sent By ccole Date 2020-11-16 Time 14:49 Rev Time 0.00
Received By ccole Date 2020-11-13 Time 08:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-10-06 Cont ID  
Sent By ccole Date 2020-10-06 Time 17:27 Rev Time 0.00
Received By ccole Date 2020-10-06 Time 10:58 Sent To  
Notes
2020-10-06 17:27:391ST REVIEW FBC-2017 PLUMBING
 PERMIT- 20100213
 10/6/2020
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE REVISED PLANS DO NOT SHOW ANY CHANGES THAT
 CORRELATE WITH REVISION 2 WHICH IS LISTED IN THE
 REVISION SCHEDULE ON EACH PLAN SHEET- SECTION 107.2.1
 WPB.
  
 2) SHEET P101: NEW FLOOR SINKS AND HAND SINKS IN THE
 KITCHEN SHALL CONNECT TO THE GREASE WASTE LINE- SECTION
 1003.3.1 FBC P AND SEC.90-126(7) CITY OF WPB CODE OF
 ORDINANCES. THE PLAN SHOWS CONNECTIONS INTO THE
 SANITARY- PLEASE CORRECT.
  
 3) P101, P102, P202, P203: PROVIDE A REVISED PLUMBING
 FIXTURE SCHEDULE CORRELATING WITH THE NEW P FIXTURES
 SHOWN ON THE PLANS- SECTION 107.2.1 WPB. PLEASE NOTE
 THE APPROVED PLAN UNDER PERMIT-17121049 HAD AN
 EQUIPMENT SCHEDULE ON SHEET P201. A COMPLETE REVIEW OF
 THE PLANS CANNOT BE COMPLETED WITHOUT THE SCHEDULE.
  
 4) P101: SUBMIT REVISED CIVIL PLANS SHOWING THE
 SANITARY AND GREASE WASTE LINE CONTINUATIONS AND
 LOCATION OF THE GREASE INTERCEPTOR- SECTION 107.2.1
 WPB.
  
 5) P101: PROVIDE GREASE WASTE CALCULATIONS AND AN
 EQUIPMENT SCHEDULE ON THE PLAN FOR THE GREASE
 INTERCEPTOR- SECTIONS 1003.3.4 & 1003.3.6 FBC P. PLEASE
 NOTE THAT ALL REVISIONS TO THE GREASE WASTE SYSTEM ON
 THE MASTER PERMIT SHALL ALSO BE APPLICABLE TO THE
 GREASE INTERCEPTOR PERMIT- 19060937.
  
 6) P102, P201: PROVIDE EQUIPMENT SCHEDULES FOR THE
 TANKLESS WATER HEATERS INDICATING THE MAKES, MODEL
 NUMBERS, BTUH CAPACITIES, LISTING STANDARDS, AND
 EFFICIENCY RATINGS- SECTION 624.1 FBC FG, AND TABLE
 C404.2 FBC EC. A) PROVIDE A FRONT ELEVATION VIEW OF THE
 WATER HEATER MOUNTING LOCATION SHOWING CLEARANCE
 DISTANCES FROM GRADE, OVERHEAD CONSTRUCTION, AND
 MECHANICAL AIR INTAKES AND OPERABLE OPENINGS INTO THE
 BUILDING- SECTION 624.1 AND 503.1 FBC FG.
  
 7) P102 & P202: SHOW THE LOCATION OF THE HOT WATER
 CIRCULATION PUMP AND PROVIDE AN EQUIPMENT SCHEDULE-
 SECTION 607.2.1 FBC P.
  
 8) P102, P201: INDICATE THE TYPE AND THICKNESS OF THE
 HOT WATER PIPING INSULATION TO BE INSTALLED ON THE
 EXTERIOR AND INTERIOR HOT WATER PIPING- TABLE C403.2.10
 FBC EC.
  
 9) P102 & P202: PROVIDE A PLUMBING DEVICE SCHEDULE
 INDICATING THE MAKES AND MODEL NUMBERS OF THE MIXING
 VALVES, BACKFLOW PREVENTERS, WATER HAMMER ARRESTORS,
 AND TRAP PRIMERS- SECTIONS 607.1.2, 608.1, 604.9,
 1002.4.1.1 FBC P. PLEASE INCLUDE THE LISTING NUMBERS OF
 THE DEVICES.
  
 10) P103: SHOW THE LOCATIONS OF TRAP PRIMERS ON THE
 RISER DRAWINGS- SECTION 1002.4.1.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-12-08 Cont ID  
Sent By jgomez Date 2020-12-08 Time 17:00 Rev Time 0.00
Received By jgomez Date 2020-12-08 Time 16:43 Sent To  
Notes
2020-12-08 17:01:291-DRAWINGS WITH ARCHITECT'S EMBOSSED SEAL AND ORIGINAL
 SIGNATURE MATCH APPROVED ONES. JG.
 2- DRAWINGS WITH ENGINEER'S ORIGINAL SEAL/SIGNATURE
 MATCH APPROVED ONES. JG.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-11-12 Cont ID  
Sent By medwards Date 2020-11-12 Time 10:36 Rev Time 0.00
Received By medwards Date 2020-11-12 Time 10:36 Sent To  
Notes
2020-11-12 10:36:59PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-10-06 Cont ID  
Sent By medwards Date 2020-10-06 Time 15:46 Rev Time 0.00
Received By medwards Date 2020-10-06 Time 15:46 Sent To  
Notes
2020-10-06 15:46:48PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  