Plan Review Details - Permit 20100119
Plan Review Stops For Permit 20100119 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
4 |
Status |
P |
Date |
2021-07-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-07-28 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-07-28 |
Time |
15:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
3 |
Status |
F |
Date |
2021-06-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-06-30 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2021-06-30 09:00:34 | TO THE BUILDING CONTRACTOR: | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected] . THE INFORMATION SHOULD BE IN | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | LINE. | | | | |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
F |
Date |
2021-03-08 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-03-08 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2021-03-08 |
Time |
08:30 |
Sent To |
|
|
Notes |
2021-03-08 09:56:24 | TO THE BUILDING CONTRACTOR: | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING: THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE. |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2021-01-11 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-01-11 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2021-01-11 |
Time |
11:48 |
Sent To |
|
|
Notes |
2021-01-11 14:00:46 | COMMERCIAL ASBESTOS | | | | TO THE BUILDING CONTRACTOR: | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING: THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2021-07-07 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-07-07 |
Time |
17:16 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2021-07-07 |
Time |
16:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2021-06-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-06-30 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2021-06-30 08:58:26 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | SERVICES/ BUILDING DIVISION | | 2017 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 20100119 | | ADD: 1900 CONSULATE PL. SUITE: 2102 | | CONT: MOSS DEVCO INC | | TEL: 561-644-0302 | | E-MAIL: [email protected] | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 3RD REVIEW | | DATE: WED. JUNE 308TH/ 2021 | | ACTION: DENIED | | | | NOTICE ONLY!!!! 4X FEE / NOTICE!!!!! FLORIDA STATUTE | | 553.80(2)(B). WITH RESPECT TO EVALUATION OF DESIGN | | PROFESSIONALS? DOCUMENTS, IF A LOCAL GOVERNMENT FINDS | | IT NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE | | FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | REVIEW. | | | | | | 0.1) 2ND REQUEST. THE SUBMITTED PLANS DID NOT KEEP THE | | SAME NAMING CONVENTION TO BE ABLE TO SEE VERSION 1 AND | | VERSION 2 AT THE SAME TIME, TO SEE WHAT IS NEW, CHANGED | | AND OR DELETED. | | 107.2.1.3. QUALITY OF PLANS. THE BUILDING OFFICIAL MAY | | ESTABLISH THROUGH DEPARTMENT POLICY OTHER STANDARDS FOR | | THE PLANS AND SPECIFICATIONS IN ORDER TO PROVIDE | | CONFORMITY TO ITS RECORD RETENTION PROGRAM. THIS POLICY | | MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, SHAPE, | | CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO RECORD | | MANAGEMENT. ELECTRONIC MEDIA MUST BE COMPATIBLE WITH | | THE ARCHIVE REQUIREMENTS OF FLORIDA STATUTES. | | | | 0.2) 2ND REQUEST. NEW SHEETS BARRY K COVERSHEET REV. | | AND BARRY KNIGHT EXTG FLOOR BOTH SUBMITTED 2/25/2021 DO | | NOT HAVE ANY SIGNATURE AND SEAL PRINTED NOR DIGITAL. | | 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING | | ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES), | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A | | DOCUMENT IN THE FILE FOLDER, SCANNED, FACSIMILE, | | DIGITALLY CREATED OR COPIED IMAGE OF THE LICENSEE?S | | SIGNATURE SHALL NOT BE USED ON DIGITALLY SIGNED AND | | SEALED ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR | | OTHER DOCUMENTS. | | | | 1). THE REVISED COVERSHEET STILL HAS THE SAME COMMENT | | ABOUT THE REQUIRED CODE REQUIREMENTS. THERE IS AN | | ADDITIONAL STATEMENT SEE ATTACHED UNDERLAYMENT | | SPECIFICATIONS. THERE ARE NO ATTACHED UNDERLAYMENT | | SPECIFICATIONS ATTACHED. AGAIN, WE DO NOT WANT TO SEE | | SPECIFICATIONS. WE REQUIRE THE ACTUAL TEST RESULTS AS | | STATED IN THE FIRST REVIEW. | | 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | CODE, CHAPTER 1, ADMINISTRATION 107.2.1. | | W.P.B. ADMINISTRATIVE CODE/2017 DRAWINGS & | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC TO | | THE TECHNICAL CODES "CODE SECTIONS SHALL NOT BE CITED | | AS A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | | | 3RD ROUND OF COMMENTS. C-1. THERE IS A STATEMENT ABOUT | | SOUND FLOOR UNDERLAYMENT TO MEET THE FBC 2017, 6TH | | EDITION. PLEASE CONFIRM IF THERE IS FLOOR FINISHES TO | | BE REMOVED AND NEW FLOOR UNDERLAYMENT AND THE TYPE OF | | NEW FLOOR FINISHES. IF THERE ARE NO NEW FLOOR FINISHES | | PLEASE REMOVE THIS NOTE. | | | | FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL | | NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR | | ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE | | QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A | | 6 INCH CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: | | PLEASE PROVIDE ALL THREE TEST REPORTS SHOWING | | COMPLIANCE WITH: | | TYPE I AND II BUILDINGS | | 1A)3RD REQUEST. FBC-B 2017 1207.3 STRUCTURE-BORNE | | SOUND. FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS | | OR BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492. | | | | 1B) 3RD REQUEST. FBC-B 2017 1207.2 AIR-BORNE SOUND. | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | E 90. | | | | 1C) 3RD REQUEST. FLAME SPREAD- FBC-B 2017 603.1. | | EXCEPTION 2. INSULATION INSTALLED BETWEEN A FINISHED | | FLOOR AND SOLID DECKING WITHOUT INTERVENING AIRSPACE | | SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT | | MORE THAN 200. | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | 2-4) COMPLIED. | | | | 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | REVIEW CYCLE. | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | 19 | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | 561-718-9724. | | WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ | | RETIRED. | | | | JAMES A. WITMER BN, PX, SFP, CBO |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2021-03-08 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-03-08 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2021-03-08 |
Time |
08:29 |
Sent To |
|
|
Notes |
2021-03-08 09:55:04 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | SERVICES/ BUILDING DIVISION | | 2017 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 20100119 | | ADD: 1900 CONSULATE PL. SUITE: 2102 | | CONT: MOSS DEVCO INC | | TEL: 561-644-0302 | | E-MAIL: [email protected] | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: MON. MARCH 08TH/ 2021 | | ACTION: DENIED | | | | NOTICE ONLY!!!! 4X FEE / NOTICE!!!!! FLORIDA STATUTE | | 553.80(2)(B). WITH RESPECT TO EVALUATION OF DESIGN | | PROFESSIONALS? DOCUMENTS, IF A LOCAL GOVERNMENT FINDS | | IT NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE | | FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | REVIEW. | | | | | | 0.1) NEW COMMENT. THE SUBMITTED PLANS DID NOT KEEP THE | | SAME NAMING CONVENTION TO BE ABLE TO SEE VERSION 1 AND | | VERSION 2 AT THE SAME TIME, TO SEE WHAT IS NEW, CHANGED | | AND OR DELETED. | | 107.2.1.3. QUALITY OF PLANS. THE BUILDING OFFICIAL MAY | | ESTABLISH THROUGH DEPARTMENT POLICY OTHER STANDARDS FOR | | THE PLANS AND SPECIFICATIONS IN ORDER TO PROVIDE | | CONFORMITY TO ITS RECORD RETENTION PROGRAM. THIS POLICY | | MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, SHAPE, | | CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO RECORD | | MANAGEMENT. ELECTRONIC MEDIA MUST BE COMPATIBLE WITH | | THE ARCHIVE REQUIREMENTS OF FLORIDA STATUTES. | | | | 0.2) NEW COMMENT. NEW SHEETS BARRY K COVERSHEET REV. | | AND BARRY KNIGHT EXTG FLOOR BOTH SUBMITTED 2/25/2021 DO | | NOT HAVE ANY SIGNATURE AND SEAL PRINTED NOR DIGITAL. | | 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING | | ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES), | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A | | DOCUMENT IN THE FILE FOLDER, SCANNED, FACSIMILE, | | DIGITALLY CREATED OR COPIED IMAGE OF THE LICENSEE?S | | SIGNATURE SHALL NOT BE USED ON DIGITALLY SIGNED AND | | SEALED ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR | | OTHER DOCUMENTS. | | | | 1) 2ND ROUND OF COMMENTS. THE REVISED COVERSHEET STILL | | HAS THE SAME COMMENT ABOUT THE REQUIRED CODE | | REQUIREMENTS. THERE IS AN ADDITIONAL STATEMENT SEE | | ATTACHED UNDERLAYMENT SPECIFICATIONS. THERE ARE NO | | ATTACHED UNDERLAYMENT SPECIFICATIONS ATTACHED. AGAIN, | | WE DO NOT WANT TO SEE SPECIFICATIONS. WE REQUIRE THE | | ACTUAL TEST RESULTS AS STATED IN THE FIRST REVIEW. | | 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | CODE, CHAPTER 1, ADMINISTRATION 107.2.1. | | W.P.B. ADMINISTRATIVE CODE/2017 DRAWINGS & | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC TO | | THE TECHNICAL CODES "CODE SECTIONS SHALL NOT BE CITED | | AS A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | | | 1ST ROUND COMMENTS. COVERSHEET C-1. THERE IS A | | STATEMENT ABOUT SOUND FLOOR UNDERLAYMENT TO MEET THE | | FBC 2017, 6TH EDITION. PLEASE CONFIRM IF THERE IS FLOOR | | FINISHES TO BE REMOVED AND NEW FLOOR UNDERLAYMENT AND | | THE TYPE OF NEW FLOOR FINISHES. IF THERE ARE NO NEW | | FLOOR FINISHES PLEASE REMOVE THIS NOTE. | | | | FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL | | NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR | | ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE | | QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A | | 6 INCH CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: | | PLEASE PROVIDE ALL THREE TEST REPORTS SHOWING | | COMPLIANCE WITH: | | TYPE I AND II BUILDINGS | | 1A)2ND REQUEST. FBC-B 2017 1207.3 STRUCTURE-BORNE | | SOUND. FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS | | OR BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492. | | | | 1B) 2ND REQUEST. FBC-B 2017 1207.2 AIR-BORNE SOUND. | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | E 90. | | | | 1C) 2ND REQUEST. FLAME SPREAD- FBC-B 2017 603.1. | | EXCEPTION 2. INSULATION INSTALLED BETWEEN A FINISHED | | FLOOR AND SOLID DECKING WITHOUT INTERVENING AIRSPACE | | SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT | | MORE THAN 200. | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | 2) COMPLIED. COVERSHEET C-1 CLASSIFIES THE BUILDING AS | | A 21 STORY FULLY SPRINKLERED HIGH RISE. CONSTRUCTION | | TYPE IIB. PLEASE REVIEW THE 2017 FBC-B TABLE 504.4. | | TYPE IIB CONSTRUCTION CAN ONLY GO 5 STORIES TALL. FOR A | | 21 STORY R-2 HIGH RISE THE CONSTRUCTION TYPE WOULD BE | | REQUIRED TO BE TYPE: I-A. | | | | 3) SHEET 01 THE EXISTING FLOOR PLAN: | | 3A) COMPLIED. THE BUILDING DATA LIST THIS BUILDING | | CONSTRUCTION TYPE AS VB. PLEASE CORRECT THE PLANS. FOR | | A 21 STORY | | R-2 HIGH RISE THE CONSTRUCTION TYPE WOULD BE REQUIRED | | TO BE TYPE: I-A. 2017 FBC-B TABLE 504.4. | | | | 3B) COMPLIED.T HE BUILDING DATA LIST THE OCCUPANCY AS | | R-3. PLEASE NOTE R-3 CONSTRUCTION IS FOR 1 & 2 FAMILY | | DWELLINGS, THIS IS A 21 STORY HIGHRISE RESIDENTIAL R-2 | | OCCUPANCY. 2017 FBC-B 310.4, PLEASE UPDATE PLANS. | | | | 4) SHEET 02 THE PROPOSED FLOOR PLAN: | | 4A) COMPLIED. IN THE BUILDING DATA BOX THE BUILDING | | DATA IS LEFT BLANK. FOR A 21 STORY R-2 HIGH RISE THE | | CONSTRUCTION TYPE WOULD BE REQUIRED TO BE TYPE: I-A. | | 2017 FBC-B TABLE 504.4. | | | | 4B 2ND REUEST. SEMI-COMPLIED, NO HEIGTH GIVEN. SHEET 02 | | THE PROPOSED WORK, NOTE # 3 INDICATES THAT THE EXISTING | | SHOWER IS GOING TO BE ENLARGED, PLANS ARE SILENT AS TO | | THE TYPE OF BACKER BOARD TO BE INSTALLED NOR THE HEIGHT | | OF THE TILE IN THE SHOWER. | | | | 4B)(1) COMPLIED. 2017 FBC-B 2509.2 BASE FOR TILE. | | MATERIALS USED AS A BASE FOR WALL TILE IN TUB AND | | SHOWER AREAS AND WALLS AND CEILING PANELS IN SHOWER | | AREAS SHALL BE OF MATERIALS LISTED IN TABLE 2509.2 AND | | INSTALLED IN ACCORDANCE WITH MANUFACTURERS | | RECOMMENDATIONS. WATER RESISTANT GYPSUM BACKING BOARD | | SHALL BE USED AS A BASE FOR TILE IN WATER CLOSET | | COMPARTMENT WALLS WHEN INSTALLED IN ACCORDANCE WITH | | GA-216 OR ASTM C840 AND THE MANUFACTURES | | RECOMMENDATIONS. | | | | 4B)( 2) 2ND REQUEST, NO HEIGTH GIVEN FOR SHOWER. 2017 | | FBC-B SHOWERS & TUBS 1210.3. SHOWER COMPARTMENTS AND | | BATHTUBS WITH INSTALLED SHOWER HEADS SHALL BE FINISHED | | WITH A NONABSORBENT SURFACE TO A HEIGHT NOT LESS THAN | | 72 INCHES ABOVE THE DRAIN INLET. | | | | 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | REVIEW CYCLE. | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | 19 | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | 561-718-9724. | | WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ | | RETIRED. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-01-11 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-01-11 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2021-01-11 |
Time |
11:48 |
Sent To |
|
|
Notes |
2021-01-11 11:49:25 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | SERVICES/ BUILDING DIVISION | | 2017 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 20100119 | | ADD: 1900 CONSULATE PL. SUITE: 2102 | | CONT: MOSS DEVCO INC | | TEL: 561-644-0302 | | E-MAIL: [email protected] | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: JAN. 11TH/ 2021 | | ACTION: DENIED | | | | 1) COVERSHEET C-1. THERE IS A STATEMENT ABOUT SOUND | | FLOOR UNDERLAYMENT TO MEET THE FBC 2017, 6TH EDITION. | | PLEASE CONFIRM IF THERE IS FLOOR FINISHES TO BE REMOVED | | AND NEW FLOOR UNDERLAYMENT AND THE TYPE OF NEW FLOOR | | FINISHES. IF THERE ARE NO NEW FLOOR FINISHES PLEASE | | REMOVE THIS NOTE. | | | | FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL | | NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR | | ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE | | QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A | | 6 INCH CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: | | PLEASE PROVIDE ALL THREE TEST REPORTS SHOWING | | COMPLIANCE WITH: | | TYPE I AND II BUILDINGS | | 1A) FBC-B 2017 1207.3 STRUCTURE-BORNE SOUND. | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492. | | | | 1B) FBC-B 2017 1207.2 AIR-BORNE SOUND. WALLS, | | PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR | | AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E | | 90. | | | | 1C) FLAME SPREAD- FBC-B 2017 603.1. EXCEPTION 2. | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | 2) COVERSHEET C-1 CLASSIFIES THE BUILDING AS A 21 STORY | | FULLY SPRINKLERED HIGH RISE. CONSTRUCTION TYPE IIB. | | PLEASE REVIEW THE 2017 FBC-B TABLE 504.4. TYPE IIB | | CONSTRUCTION CAN ONLY GO 5 STORIES TALL. FOR A 21 STORY | | R-2 HIGH RISE THE CONSTRUCTION TYPE WOULD BE REQUIRED | | TO BE TYPE: I-A. | | | | 3) SHEET 01 THE EXISTING FLOOR PLAN: | | 3A) THE BUILDING DATA LIST THIS BUILDING CONSTRUCTION | | TYPE AS VB. PLEASE CORRECT THE PLANS. FOR A 21 STORY | | R-2 HIGH RISE THE CONSTRUCTION TYPE WOULD BE REQUIRED | | TO BE TYPE: I-A. 2017 FBC-B TABLE 504.4. | | | | 3B) THE BUILDING DATA LIST THE OCCUPANCY AS R-3. PLEASE | | NOTE R-3 CONSTRUCTION IS FOR 1 & 2 FAMILY DWELLINGS, | | THIS IS A 21 STORY HIGHRISE RESIDENTIAL R-2 OCCUPANCY. | | 2017 FBC-B 310.4, PLEASE UPDATE PLANS. | | | | 4) SHEET 02 THE PROPOSED FLOOR PLAN: | | 4A) IN THE BUILDING DATA BOX THE BUILDING DATA IS LEFT | | BLANK. FOR A 21 STORY R-2 HIGH RISE THE CONSTRUCTION | | TYPE WOULD BE REQUIRED TO BE TYPE: I-A. 2017 FBC-B | | TABLE 504.4. | | | | 4B) SHEET 02 THE PROPOSED WORK, NOTE # 3 INDICATES THAT | | THE EXISTING SHOWER IS GOING TO BE ENLARGED, PLANS ARE | | SILENT AS TO THE TYPE OF BACKER BOARD TO BE INSTALLED | | NOR THE HEIGHT OF THE TILE IN THE SHOWER. | | | | 4B)(1) 2017 FBC-B 2509.2 BASE FOR TILE. MATERIALS USED | | AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND | | WALLS AND CEILING PANELS IN SHOWER AREAS SHALL BE OF | | MATERIALS LISTED IN TABLE 2509.2 AND INSTALLED IN | | ACCORDANCE WITH MANUFACTURER?S RECOMMENDATIONS. WATER | | RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A BASE | | FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN | | INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C840 AND | | THE MANUFACTURE?S RECOMMENDATIONS. | | | | 4B)( 2) 2017 FBC-B SHOWERS & TUBS 1210.3. SHOWER | | COMPARTMENTS AND BATHTUBS WITH INSTALLED SHOWER HEADS | | SHALL BE FINISHED WITH A NONABSORBENT SURFACE TO A | | HEIGHT NOT LESS THAN 72 INCHES ABOVE THE DRAIN INLET. | | | | 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | REVIEW CYCLE. | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | 19 | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | 561-718-9724. | | WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ | | RETIRED. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2021-07-21 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-07-21 |
Time |
18:26 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-07-21 |
Time |
18:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2021-03-08 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-03-08 |
Time |
15:43 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-03-08 |
Time |
15:43 |
Sent To |
|
|
Notes |
2021-03-08 15:43:54 | CODES IN EFFECT | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SAME COMMENTS AS | | FIRST REVIEW. | | | | 1) PLEASE SHOW LOCATION OF EXISTING SMOKE ALARMS. IF | | NONE ARE EXISTING OR NOT TO CODE, SHOW AS NEW | | INSTALLATIONS. FBC RE R314.2, FBC 314.3; WPB FBC | | 107.2.1 | | 2) ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE | | CORRECTION. NEC 210.12; FBC RE E3902.16 (A NOTE WILL | | SUFFICE) | | 3) PROVIDE SPECS FOR NEW LIGHTS TO COMPLY WITH FBC EC | | R404.1 "A MINIMUM OF 75 PERCENT OF THE LAMPS IN | | PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE | | HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF THE | | PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN | | ONLY HIGH EFFICACY LAMPS". (A NOTE WILL SUFFICE) | | | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | ENRIQUE QUINONEZ | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2021-01-29 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2021-01-29 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2021-01-29 |
Time |
10:33 |
Sent To |
|
|
Notes |
2021-01-29 11:17:32 | CODES IN EFFECT | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | REVIEW STATUS: FAILED. | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1) PLEASE SHOW LOCATION OF EXISTING SMOKE ALARMS. IF | | NONE ARE EXISTING OR NOT TO CODE, SHOW AS NEW | | INSTALLATIONS. FBC RE R314.2, FBC 314.3; WPB FBC | | 107.2.1 | | 2) ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE | | CORRECTION. NEC 210.12; FBC RE E3902.16 (A NOTE WILL | | SUFFICE) | | 3) PROVIDE SPECS FOR NEW LIGHTS TO COMPLY WITH FBC EC | | R404.1 "A MINIMUM OF 75 PERCENT OF THE LAMPS IN | | PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE | | HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF THE | | PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN | | ONLY HIGH EFFICACY LAMPS". (A NOTE WILL SUFFICE) | | | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | ENRIQUE QUINONEZ | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2021-07-01 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-07-01 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-07-01 |
Time |
16:42 |
Sent To |
|
|
Notes |
2021-07-01 16:47:04 | FIRE PROVISO: | | | | MAINTAIN AND PROTECT THE FIRE ALARM AND FIRE SPRINKLER | | SYSTEMS DURING DEMO AND RECONSTRUCTION. | | | | ANY WORK INVLOVING THE FA & FS SYSTEMS SHALL BE DONE | | UNDER SEPARATE PERMITS AND SHOP DRAWINGS. | | | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2021-01-06 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2021-01-06 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2021-01-06 |
Time |
15:51 |
Sent To |
|
|
Notes |
2021-01-06 16:06:33 | FIRE PROVISO: | | | | MAINTAIN AND PROTECT THE FIRE ALARM AND FIRE SPRINKLER | | SYSTEMS DURING DEMO AND RECONSTRUCTION. | | | | ANY WORK INVLOVING THE FA & FS SYSTEMS SHALL BE DONE | | UNDER SEPARATE PERMITS AND SHOP DRAWINGS. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-07-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-07-28 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-07-23 |
Time |
11:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2021-07-21 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-07-21 |
Time |
18:26 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-06-29 |
Time |
09:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-03-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-03-09 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-02-25 |
Time |
06:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
P |
Date |
2021-02-24 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-02-24 |
Time |
07:34 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-12-31 |
Time |
13:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2021-01-22 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-01-22 |
Time |
13:36 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-01-22 |
Time |
08:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2021-07-15 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-07-15 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-07-15 |
Time |
09:43 |
Sent To |
|
|
Notes |
2021-07-15 09:43:18 | 07/15/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2021-02-23 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2021-02-23 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2021-02-23 |
Time |
15:59 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2021-07-15 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-07-15 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-07-15 |
Time |
09:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2021-03-08 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-03-08 |
Time |
09:58 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2021-03-08 09:58:14 | ) NEW COMMENT. NEW SHEETS BARRY K COVERSHEET REV. AND | | BARRY KNIGHT EXTG FLOOR BOTH SUBMITTED 2/25/2021 DO NOT | | HAVE ANY SIGNATURE AND SEAL PRINTED NOR DIGITAL. | | 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING | | ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES), | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A | | DOCUMENT IN THE FILE FOLDER, SCANNED, FACSIMILE, | | DIGITALLY CREATED OR COPIED IMAGE OF THE LICENSEE?S | | SIGNATURE SHALL NOT BE USED ON DIGITALLY SIGNED AND | | SEALED ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR | | OTHER DOCUMENTS. | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | 19 | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | 561-718-9724. | | WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ | | RETIRED. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-10-05 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2020-10-05 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2020-10-05 |
Time |
10:14 |
Sent To |
|
|
Notes |
|
|
|