Plan Review Stops For Permit 20100062 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2020-11-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-14 |
Time |
13:05 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-14 |
Time |
12:56 |
Sent To |
|
|
Notes |
2020-11-14 13:11:19 | NO NOTES |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-12-02 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2020-12-02 |
Time |
21:07 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2020-12-02 |
Time |
20:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-11-16 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2020-11-12 |
Time |
22:09 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2020-11-12 |
Time |
21:38 |
Sent To |
|
|
Notes |
2020-11-12 22:09:26 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. VALUE LOW FOR AMOUNT OF WORK SHOWN. PROVIDE ACCURATE | | VALUE FBC 109.3 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-657-1653 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
P |
Date |
2020-12-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-12-21 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-12-21 |
Time |
08:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
F |
Date |
2020-11-23 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-11-23 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-11-23 |
Time |
12:06 |
Sent To |
|
|
Notes |
2020-11-23 12:40:57 | 3RD REVIEW FBC-2017 RES. FUEL GAS | | PERMIT- 20100062 | | 11/23/2020 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE NEW RISER DRAWING HAS NOTES INDICATING BOTH | | 90,000 AND 110,000 TOTAL BTUS FOR THE INTERIOR- WHICH | | IS CORRECT? | | | | 2) SHOW THE LOCATION OF THE LOW PRESSURE REGULATOR FOR | | THE INTERIOR APPLIANCES AND INDICATE IF IT IS NEW OR | | EXISTING- SECTION G2421.1 FBC RES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2020-11-06 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-11-06 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-11-06 |
Time |
15:20 |
Sent To |
|
|
Notes |
2020-11-06 15:21:01 | 2ND REVIEW FBC-2017 RES. FUEL GAS | | PERMIT- 20100062 | | 11/6/2020 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHOW THE TOTAL LOAD OF THE SYSTEM AND SHOW THE | | COOKTOP LOAD- SECTIONS G2412.3, G2412.4, & G2413.2 FBC | | RES. | | | | 2) PROVIDE THE TOTAL LENGTH DEVELOPED LENGTH OF THE | | PIPING FROM THE METER TO THE MOST REMOTE OUTLET- | | SECTIONS G2413.4.1 AND G2413.4.2 FBC RES. | | | | 3) PROVIDE THE PIPE SIZING TABLES FOR THE SYSTEM ON THE | | RISER- TABLES- G2413.4(1) ? G2413.4(8) FBC RES. | | | | 4) THE CONTRACTOR OR QUALIFIER WHO PREPARED THE DRAWING | | SHALL PROVIDE HIS/HER SIGNATURE ON IT- SECTION 107.2.1 | | WPB, AND FLORIDA STATUTES 471.003(2)(H) & 471.025. | | | | 5) PLEASE CORRECT THE NOTE ON THE SURVEY TO INDICATE | | THE MINIMIUM10 FT. CLEARANCE TO MECHANICAL AND GRAVITY | | AIR INTAKES INTO THE BUILDING- SECTION R303.5.1 RES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-11-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-11-05 |
Time |
10:58 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-11-05 |
Time |
10:43 |
Sent To |
|
|
Notes |
2020-11-05 11:00:55 | 1ST REVIEW FBC-2017 RES. FUEL GAS | | PERMIT- 20100062 | | 11/5/2020 | | | | CODES IN EFFECT: | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SUBMIT A GAS RISER DRAWING SHOWING THE COMPLETE GAS | | PIPING SYSTEM INCLUDING THE PIPING FOR THE GENERATOR, | | AND THE EXISTING PIPING INSTALLED UNDER PREVIOUS | | PERMITS- 05031319 & 05090083- SECTIONS G2412.3 & | | G2412.4 FBC RES. | | | | A) SHOW THE TOTAL LOAD AND THE INDIVIDUAL LOADS OF THE | | SYSTEM- SECTIONS G2412.3, G2412.4, & G2413.2 FBC RES. | | | | B) PROVIDE THE TOTAL LENGTH DEVELOPED LENGTH OF THE | | PIPING FROM THE METER TO THE MOST REMOTE OUTLET, AND | | THE INDIVIDUAL BRANCH LENGTHS- SECTIONS G2413.4.1 AND | | G2413.4.2 FBC RES. | | | | C) SHOW THE LOCATIONS OF SHUT OFF VALVES AND PIPE | | UNIONS- SECTIONS G2420.5 & G2422.1.4. | | | | D) SHOW THE LOCATIONS OF NEW AND EXISTING REGULATORS. | | INDICATE THE MAKES AND MODELS OF THE REGULATORS AND | | THEIR INLET AND OUTLET PRESSURES- SECTION G2421.1 & | | G2421.2. SUBMIT MARKED UP OR HIGHLIGHTED SPECS SHOWING | | THE SELECTED MODEL, THE MAX INLET AND OUTLET SIZE AND | | PRESSURES, SPRING DATA, AND ORIFICE SIZE. | | | | 2) PLEASE CORRECT THE NOTE ON THE SURVEY TO INDICATE | | THE MINIMIUM10 FT. CLEARANCE TO MECHANICAL AND GRAVITY | | AIR INTAKES INTO THE BUILDING- SECTION R303.5.1 RES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-12-21 |
Time |
|
Rev Time |
0.00 |
Received By |
ccarvaja |
Date |
2020-12-11 |
Time |
18:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-12-02 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2020-12-02 |
Time |
21:07 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2020-11-20 |
Time |
15:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-11-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-14 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-10-30 |
Time |
09:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
N |
Date |
2020-12-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-12-21 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-12-21 |
Time |
08:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2020-11-23 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-11-23 |
Time |
12:25 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-11-23 |
Time |
12:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2020-11-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-11-05 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-11-05 |
Time |
10:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2020-12-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-12-21 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-12-21 |
Time |
08:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-11-23 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-11-23 |
Time |
12:42 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-11-23 |
Time |
12:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-11-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-14 |
Time |
13:04 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-14 |
Time |
12:56 |
Sent To |
|
|
Notes |
2020-11-14 13:05:19 | PLAN REVIEW / SIGNATURES | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | RE: PRE-CAST GENERATOR PAD | | | | | | 1. DIGITAL SIGNATURE ON PRE-CAST GENERATOR PAD | | ENGINEERING IS OUT OF DATE. SEE ENGINEER'S NOTE: "FOR | | PERMIT USE WITHIN 14 DAYS OF DIGITAL SEAL". DATE OF | | SEAL IS 07-15-2020. | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | WET SEAL AND SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2020-11-05 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-11-05 |
Time |
|
Rev Time |
|
Received By |
rthermid |
Date |
2020-11-05 |
Time |
|
Sent To |
I |
|
Notes |
|
|