Plan Review Details - Permit 20091355
Plan Review Stops For Permit 20091355
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-10-13 Cont ID  
Sent By jwitmer Date 2020-10-13 Time 09:45 Rev Time 0.00
Received By jwitmer Date 2020-10-13 Time 09:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-10-06 Cont ID  
Sent By jwitmer Date 2020-10-06 Time 10:14 Rev Time 0.00
Received By jwitmer Date 2020-10-06 Time 09:02 Sent To  
Notes
2020-10-06 10:14:22FBC- BUILDING PLAN REVIEW
 W. 2017 P. B. REVISION: 20091355
 W. P. B. PERMIT: 20050806
 ADD: 515 N. FLAGLER DR. SUITE: 650
 CONT: CHANDLER CONSTRUCTION
 TEL: 561-791-6934
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUESDAY OCT. 06TH/2020
 ACTION: DENIED
  
 1) IN THE ORIGINAL ISSUED PERMIT 20050806 SHOWS A
 PARALLEL APPROACH ON SHEET A4.21 DETAIL # 7. THIS SAME
 DETAIL POINTS TO THE SAME PAGE DETAIL # 9 WHICH STATES
 PROVIDE 3 FEET OPEN SPACE UNDERNEATH SINK FOR
 ACCESSIBILITY. THIS SAME DETAIL HAS A CUT SECTION
 THROUGH THE ACCESSIBLE AREA UNDER THE CAF? SINK DETAILS
 # 2 & 5/ PAGE A5.51. PAGE A5.51 DETAIL #2 SHOWS THE
 BASE CABINET AND REQUIRED CLEARANCES FOR A FORWARD
 APPROACH.
 THE SUBMITTED REVISION 20091355 ON SHEET A4.21 STILL
 SHOWS THE CUT SECTION THROUGH THE BASE CABINET PAGE
 A5.51 DETAILS 2 & 5 AND THE REQUIREMENTS CLEAR FLOOR
 SPACE FOR KNEES AND TOES FOR THE FORWARD APPROACH,
 SHOULD THIS DETAIL ALSO BE DELETED SINCE YOU ARE
 LOOKING TO USE A SIDE APPROACH. I BELIEVE YOU ARE
 TRYING TO USE THE EXCEPTION# 1 UNDER 606.2 IN THE 2017
 FBC-ACCESSIBILITY CODE. A PARALLEL APPROACH COMPLYING
 WITH 305 SHALL BE PERMITTED TO A KITCHEN SINK, IN A
 SPACE WHERE A COOK TOP OR CONVENTIONAL RANGE IS NOT
 PROVIDED, AND TO WET BARS.
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19, IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-10-13 Cont ID  
Sent By jwitmer Date 2020-10-13 Time 09:46 Rev Time 0.00
Received By jwitmer Date 2020-10-08 Time 14:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-10-06 Cont ID  
Sent By jwitmer Date 2020-10-06 Time 10:14 Rev Time 0.00
Received By jwitmer Date 2020-09-30 Time 16:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-10-09 Cont ID  
Sent By ccole Date 2020-10-09 Time 13:20 Rev Time 0.00
Received By ccole Date 2020-10-09 Time 11:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-10-01 Cont ID  
Sent By ccole Date 2020-10-01 Time 15:02 Rev Time 0.00
Received By ccole Date 2020-10-01 Time 13:07 Sent To  
Notes
2020-10-01 15:02:551ST REVIEW FBC-2017 PLUMBING
 PERMIT- 200901355
 10/1/2020
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS A4.2.1: THE ACCESSIBLE CAFE SINK WAS DESIGNED
 FOR A PARALLEL APPROACH UNDER MASTER PERMIT 20050806
 AND KNEE AND TOE CLEARANCES FOR A FORWARD APPROACH WERE
 NOT PROVIDED ON THE MASTER PLAN- SHEETS A0.04 & A4.21.
 PLEASE PROVIDE A DETAIL PER SECTIONS 606.2 AND 306.1
 FBC ACC.
  
 2) TP6: NEW DRAIN PENETRATIONS OF THE EXISTING SLAB MAY
 REQUIRE AN X-RAY TO LOCATE REINFORCING STEEL OR POST
 STRESSED FLOOR TENDONS. PLEASE PLACE A NOTE ON THE
 PLANS TO VERIFY COMPLIANCE WILL BE MET- SECTION 107.2.1
 WPB.
  
 3) TP6: NEW DRAIN PIPE PENETRATIONS OF THE EXISTING
 SLAB WILL REQUIRE FIRESTOPPING TO SEAL THE ANNULAR
 SPACE AROUND THE PIPING. PROVIDE A UL TESTED AND
 APPROVED FIRESTOPPING ASSEMBLY DETAIL ON THE PLAN-
 SECTION 714.4.1.2 FBC B.
  
 4) TP6: PLEASE INDICATE THE CODE SECTIONS YOU ARE
 REFERENCING IN NOTE #4 ABOUT NOT PROVIDING THE TRAP
 PRIMER, AND THE INSULATION OF THE ICE MAKER DRAIN IN
 MULTI-STORY BUILDINGS. HAT YOU ARE USING IN REFERENCE
 TO NOTE #4- SECTION 107.2.1 WPB. IN ACCORDANCE WITH
 SECTION 1002.4.1 FBC P IT APPEARS A TRAP PRIMER IS
 REQUIRED.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-10-09 Cont ID  
Sent By ccole Date 2020-10-09 Time 13:20 Rev Time 0.00
Received By ccole Date 2020-10-09 Time 13:20 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-10-01 Cont ID  
Sent By ccole Date 2020-10-01 Time 15:05 Rev Time 0.00
Received By ccole Date 2020-10-01 Time 15:05 Sent To  
Notes
***NONE***