Plan Review Details - Permit 20091221
Plan Review Stops For Permit 20091221
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2020-10-14 Cont ID  
Sent By tklarge Date 2020-10-14 Time 12:55 Rev Time 0.00
Received By tklarge Date 2020-10-14 Time 12:55 Sent To  
Notes
2020-10-14 12:56:18CONNECT TO OLD EXISTING GAS SYSTEM.

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-10-02 Cont ID  
Sent By ccole Date 2020-10-02 Time 18:32 Rev Time 0.00
Received By ccole Date 2020-10-02 Time 15:32 Sent To  
Notes
2020-10-02 18:33:011ST REVIEW FBC-2017 RES. FUEL GAS.
 PERMIT-20091221
 10/2/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) I HAVE RESEARCHED THE WPB BUILDING DEPT. RECORDS AND
 WAS UNABLE TO LOCATE A PERMIT OR PLANS FOR PREVIOUS
 INSTALLATIONS OF GAS PIPING, AND A GAS-FIRED WATER
 HEATER AT THE RESIDENCE. THE APPLICATION IS INDICATING
 A REPLACEMENT OF THE WATER HEATER, HOWEVER IF THE
 EXISTING GAS PIPING AND WATER HEATER WERE NEVER
 PERMITTED AND INSPECTED, THEN THE INSTALLATIONS MUST BE
 REVIEWED AS NEW INSTALLATIONS. PLEASE PROVIDE GAS PLANS
 SHOWING THE LOCATION OF THE WATER HEATER AND INCLUDE A
 GAS RISER DRAWING, COMBUSTION AIR CALCULATIONS, AND A
 VENTING DIAGRAM- SECTION 107.2.1 WPB. PLEASE NOTE THE
 RISER SHALL SHOW THE COMPLETE GAS PIPING SYSTEM
 INCLUDING ALL NEW AND EXISTING BRANCH PIPES AND
 GAS-FIRED APPLIANCES AT THE RESIDENCE- SECTIONS
 G24412.3 & G2413.2 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-10-14 Cont ID  
Sent By tklarge Date 2020-10-14 Time 15:27 Rev Time 0.00
Received By tklarge Date 2020-10-14 Time 15:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-10-14 Cont ID  
Sent By tklarge Date 2020-10-14 Time 12:56 Rev Time 0.00
Received By tklarge Date 2020-10-14 Time 12:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-10-02 Time   Rev Time 0.00
Received By lmarchan Date 2020-10-01 Time 11:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-10-14 Cont ID  
Sent By tklarge Date 2020-10-14 Time 15:28 Rev Time 0.00
Received By tklarge Date 2020-10-14 Time 15:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-10-02 Cont ID  
Sent By ccole Date 2020-10-02 Time 18:10 Rev Time 0.00
Received By ccole Date 2020-10-02 Time 15:32 Sent To  
Notes
2020-10-02 18:32:021ST REVIEW FBC-2017 RES. PLUMBING
 PERMIT-20091221
 10/2/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE COST OF THE WATER HEATER SHALL BE ADDED TO THE
 TOTAL PERMIT VALUE IN ACCORDANCE WITH SECTION 109.3
 WPB. THE SUBMITTED CONTRACT INDICATES LABOR AND
 MATERIALS ONLY.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-10-02 Cont ID  
Sent By ccole Date 2020-10-02 Time 17:59 Rev Time 0.00
Received By ccole Date 2020-10-02 Time 15:32 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy