Plan Review Details - Permit 20090921
Plan Review Stops For Permit 20090921
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-09-22 Cont ID  
Sent By cthroop Date 2020-09-22 Time 11:02 Rev Time 0.00
Received By cthroop Date 2020-09-22 Time 10:55 Sent To  
Notes
2020-09-22 11:10:27PLAN REVIEW / BUILDING / TEMP. TENT
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC 2014
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 2017 FBC 6TH CHPT. 31
 SPECIAL CONSTRUCTION
  
 SECTION 3103
 TEMPORARY STRUCTURES
  
 1. SITE PLAN
  A. SHOW TO SCALE THE SIZE AND LOCATION OF NEW
 CONSTRUCTION AND EXISTING
 STRUCTURES ON THE SITE?PROVIDED
  B. SHOW DISTANCE TO LOT LINES AND OTHER STRUCTURES PER
 FBC CHPT. 6, SEC. 602
  C. PROVIDE SQUARE FOOTAGE PROVIDED
  D. PROVIDE ESTIMATED OCCUPANCY OF EACH TENT
  E. PROVIDE ACCESSIBLE ROUTE FROM PARKING TO TENT
 ENTRANCE
  F. IDENTIFY MEANS OF EGRESS PER CHPT. 10
  G. PROVIDE ACCESSIBLE ROUTE FROM TENT TO ACCESSIBLE
 RESTROOMS
  H. ACCESSIBLE RESTROOMS SHALL BE LOCATED WITHIN 500
 FEET OF TENT
 2. FOUNDATION/TIE DOWN
  A. PROVIDE DETAIL OF TIE DOWN FOR UPLIFT
  B. PROVIDE DETAIL OF ANCHORS FOR TENT LEG LATERAL
 MOVEMENT
 3. CONFORMANCE PER SECTION 3103.1.1
 TEMPORARY STRUCTURES AND USES SHALL CONFORM TO THE
 STRUCTURAL STRENGTH, FIRE SAFETY, MEANS OF EGRESS,
 ACCESSIBILITY, LIGHT, VENTILATION AND SANITARY
 REQUIREMENTS OF THIS CODE AS NECESSARY TO ENSURE PUBLIC
 HEALTH, SAFETY AND GENERAL WELFARE.
  
  
 FOR TEMPORARY MEMBRANE STRUCTURES (TENTS) WITH A SPAN
 OF 40 FEET OR GREATER IN ANY DIRECTION:
  
 A. PROVIDE DETAILS OF STRUCTURAL CONNECTIONS. INCLUDE
 BASEPLATE/TIEDOWN DETAILS.
 B. PROVIDE STRUCTURAL EVALUATION OF STRUCTURE.
  
 THESE DOCUMENTS SHALL BE REVIEWED, SIGNED AND SEALED BY
 A DESIGN PROFESSIONAL.
  
 NO EXCEPTIONS BY ORDER OF THE BUILDING OFFICIAL
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-09-30 Cont ID  
Sent By cthroop Date 2020-09-30 Time 08:50 Rev Time 0.00
Received By cthroop Date 2020-09-30 Time 08:49 Sent To  
Notes
2020-09-30 08:51:55APPLICANT SHALL APPLY FOR A METER CHECK PERMIT FOR
 TEMP. POWER POLE. A LICENSED ELECTRICIAN IS NOT
 REQUIRED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2020-09-23 Cont ID  
Sent By pleduc Date 2020-09-23 Time   Rev Time 0.00
Received By pleduc Date 2020-09-23 Time 10:49 Sent To  
Notes
2020-09-23 10:56:16THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) WHAT IS THE INTENDED PURPOSE AND PRODUCT PROPSOED
 FOR THESE TENT STRUCTURE?
  
 PLEASE PROVIDE DETAILS
  
  
  
 2) THERE ARE NO INTERIOR FLOOR LAYOUTS AND EXITS.
  
 PLEASE PROVIDE DETAILS.
  
  
 3) THERE IS NO LIGHTING INDICATED. HOW WILL LIGHTING BE
 PROVIDED WITHIN THE TENTS?
  
 PLEASE PROVIDE DETAILS
  
  
 4) THERE ARE NO TIE-DOWNS INDICATED.
  
 PLEASE PROVIDE DETAILS
  
  
  
 5) THERE APPEARS TO BE A FENCE INDICATED.
  
 WHERE ARE THE EXITS ALONG THE FENCE, HOW MANY AND THE
 SIZE OF THESE EXITS?
  
  
  
 6) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-09-30 Cont ID  
Sent By cthroop Date 2020-09-30 Time 08:47 Rev Time 0.00
Received By cthroop Date 2020-09-22 Time 09:50 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-09-29 Cont ID  
Sent By aaponte Date 2020-09-29 Time 12:19 Rev Time 0.00
Received By aaponte Date 2020-09-29 Time 12:19 Sent To  
Notes
2020-09-29 12:20:00PROVISO: A SPECIAL EVENT PERMIT REQUIRED.