Plan Review Details - Permit 20090819
Plan Review Stops For Permit 20090819
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status N Date 2021-02-16 Cont ID  
Sent By rmcdouga Date 2021-02-16 Time 10:22 Rev Time 0.00
Received By rmcdouga Date 2021-02-16 Time 10:22 Sent To  
Notes
2021-02-16 10:23:25ASBESTOS LETTER SUBMITTED FOR INTERIOR DEMO PERMIT
 #20120458.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2021-02-11 Cont ID  
Sent By rmcdouga Date 2021-02-11 Time 12:53 Rev Time 0.00
Received By rmcdouga Date 2021-02-11 Time 12:53 Sent To  
Notes
2021-02-11 12:53:33FAILED PLAN REVIEW, RESIDENTIAL:
  
 WRITTEN NOTIFICATION TO THE HEALTH DEPARTMENT IS
 REQUIRED FOR A RESIDENTIAL BUILDING HAVING 4 OR LESS
 DWELLING UNITS, IF IT HAS BEEN USED FOR COMMERCIAL
 PURPOSES OR IT IS BEING DEMOLISHED AS PART OF A
 COMMERCIAL OR PUBLIC PROJECT (WHICH INCLUDES
 CITY-INITIATED DEMOLITION OF A SINGLE FAMILY
 RESIDENCE). IF THIS PROJECT IS SUBJECT TO ASBESTOS
 NOTIFICATION REQUIREMENTS, PROVIDE A SIGNED
 ACKNOWLEDGMENT FROM THE CONTRACTOR STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF THE ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. IF THIS PROJECT IS NOT SUBJECT TO
 ASBESTOS NOTIFICATION REQUIREMENTS, THE CONTRACTOR IS
 TO PROVIDE A SIGNED STATEMENT ON LETTERHEAD EXPLAINING
 WHY IT IS EXEMPT (FOR EXAMPLE, "THIS PROJECT IS EXEMPT
 BECAUSE IT IS A SINGLE FAMILY RESIDENCE AND IS NOT A
 PART OF A COMMERCIAL OR PUBLIC PROJECT, AND IS NOT A
 CITY-INITIATED DEMOLITION").
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-10-29 Cont ID  
Sent By rmcdouga Date 2020-10-29 Time 09:37 Rev Time 0.00
Received By rmcdouga Date 2020-10-29 Time 09:37 Sent To  
Notes
2020-10-29 10:02:05FAILED PLAN REVIEW, RESIDENTIAL:
  
 WRITTEN NOTIFICATION TO THE HEALTH DEPARTMENT IS
 REQUIRED FOR A RESIDENTIAL BUILDING HAVING 4 OR LESS
 DWELLING UNITS, IF IT HAS BEEN USED FOR COMMERCIAL
 PURPOSES OR IT IS BEING DEMOLISHED AS PART OF A
 COMMERCIAL OR PUBLIC PROJECT (WHICH INCLUDES
 CITY-INITIATED DEMOLITION OF A SINGLE FAMILY
 RESIDENCE). IF THIS PROJECT IS SUBJECT TO ASBESTOS
 NOTIFICATION REQUIREMENTS, PROVIDE A SIGNED
 ACKNOWLEDGMENT FROM THE CONTRACTOR STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF THE ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. IF THIS PROJECT IS NOT SUBJECT TO
 ASBESTOS NOTIFICATION REQUIREMENTS, THE CONTRACTOR IS
 TO PROVIDE A SIGNED STATEMENT ON LETTERHEAD EXPLAINING
 WHY IT IS EXEMPT (FOR EXAMPLE, "THIS PROJECT IS EXEMPT
 BECAUSE IT IS A SINGLE FAMILY RESIDENCE AND IS NOT A
 PART OF A COMMERCIAL OR PUBLIC PROJECT, AND IS NOT A
 CITY-INITIATED DEMOLITION").
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-02-26 Cont ID  
Sent By rmcdouga Date 2021-02-26 Time 14:43 Rev Time 0.00
Received By rmcdouga Date 2021-02-26 Time 14:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-02-11 Cont ID  
Sent By rmcdouga Date 2021-02-11 Time 12:59 Rev Time 0.00
Received By rmcdouga Date 2021-02-11 Time 12:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-10-29 Cont ID  
Sent By rmcdouga Date 2020-10-29 Time 09:37 Rev Time 0.00
Received By rmcdouga Date 2020-10-29 Time 09:16 Sent To  
Notes
2020-10-29 09:56:161ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SHOW COMPLIANCE WITH FBC-R314.3.1 ALTERATIONS,
 REPAIRS AND ADDITIONS.
 WHEN ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS.
  
 2) SHOW COMPLIANCE WITH FBC-R315.1 CARBON MONOXIDE
 PROTECTION.
 EVERY SEPARATE BUILDING OR AN ADDITION TO AN EXISTING
 BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS
 ISSUED AND HAVING A FOSSIL-FUEL-BURNING HEATER OR
 APPLIANCE, A FIREPLACE, AN ATTACHED GARAGE, OR OTHER
 FEATURE, FIXTURE, OR ELEMENT THAT EMITS CARBON MONOXIDE
 AS A BYPRODUCT OF COMBUSTION SHALL HAVE AN OPERATIONAL
 CARBON MONOXIDE ALARM INSTALLED WITHIN 10 FEET OF EACH
 ROOM USED FOR SLEEPING PURPOSES.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-02-12 Cont ID  
Sent By fgiaquin Date 2021-02-12 Time 21:01 Rev Time 0.00
Received By fgiaquin Date 2021-02-12 Time 19:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-10-28 Cont ID  
Sent By fgiaquin Date 2020-10-28 Time 22:03 Rev Time 0.00
Received By fgiaquin Date 2020-10-28 Time 21:02 Sent To  
Notes
2020-10-28 22:03:11ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. NO SMOKE/CARBON ALARMS SHOWN ON PLAN. FBC RE 314 &
 315
  
 2. PROVIDE AFCI PROTECTION WHERE REQUIRED. . NEC
 210.12A&B
  
 3. PROVIDE GFCI PROTECTION WHERE REQUIRED. NEC 210.8
  
 4. TAMPERPROOF RECEPTACLES REQUIRED. NEC 406.12
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN
 PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE
 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-657-1653
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2021-02-23 Cont ID  
Sent By ccole Date 2021-02-23 Time 15:26 Rev Time 0.00
Received By ccole Date 2021-02-23 Time 15:26 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-02-11 Cont ID  
Sent By ccole Date 2021-02-11 Time 12:48 Rev Time 0.00
Received By ccole Date 2021-02-11 Time 12:21 Sent To  
Notes
2021-02-11 12:48:221ST REVIEW FBC-2017 RES. FUEL GAS.
 PERMIT- 20090819
 2/11/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) P PLAN: PROVIDE AN EQUIPMENT SCHEDULE FOR THE NEW
 WATER HEATER AND SUBMIT MANUFACTURER'S SPECIFICATIONS-
 SECTION G2448.1 FBC RES. PLEASE NOTE COMPLETE
 SPECIFICATIONS AND INSTALLATION MANUAL SHALL BE ONSITE
 AT TIME OF INSPECTION, AND THAT AN ADDITIONAL PRESSURE
 REGULATOR MAY BE REQUIRED AT THE WATER HEATER BASED ON
 MANUFACTURER'S INPUT PRESSURE SPECIFICATION.
  
 2) P PLAN: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE
 NEW RANGE SHOWING BTUH LOAD AND INPUT PRESSURE- SECTION
 G2447.1 FBC RES. PLACE A NOTE ON THE PLAN TO INDICATE
 ACCESS SHALL BE PROVIDED TO THE APPLIANCE SHUTOFF
 VALVE- G2450.5.1 FBC RES.
  
 3) THE GAS CONTRACTOR OF RECORD WHO PREPARED THE GAS
 RISER DRAWING SHALL SUBMIT A GAS SUB-PERMIT
 APPLICATION- SECTION 105.1 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-02-26 Cont ID  
Sent By rmcdouga Date 2021-02-26 Time 14:43 Rev Time 0.00
Received By rmcdouga Date 2021-02-25 Time 13:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-02-24 Cont ID  
Sent By cpuell Date 2021-02-24 Time 10:29 Rev Time 0.00
Received By cpuell Date 2021-02-24 Time 10:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-02-12 Cont ID  
Sent By fgiaquin Date 2021-02-12 Time 21:01 Rev Time 0.00
Received By fgiaquin Date 2021-02-10 Time 10:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-10-29 Cont ID  
Sent By rmcdouga Date 2020-10-29 Time 09:37 Rev Time 0.00
Received By rmcdouga Date 2020-10-20 Time 11:56 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-02-11 Cont ID  
Sent By medwards Date 2021-02-11 Time 10:35 Rev Time 0.00
Received By medwards Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-10-27 Cont ID  
Sent By medwards Date 2020-10-27 Time 08:43 Rev Time 0.00
Received By medwards Date 2020-10-27 Time 08:37 Sent To  
Notes
2020-10-27 08:44:35PROVIDE A SCOPE OF WORK FOR ALL MECHANICAL WORK FOR
 THIS PROJECT. FBC 107.2
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2021-02-23 Cont ID  
Sent By ccole Date 2021-02-23 Time 15:26 Rev Time 0.00
Received By ccole Date 2021-02-23 Time 15:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2021-02-11 Cont ID  
Sent By ccole Date 2021-02-11 Time 12:18 Rev Time 0.00
Received By ccole Date 2021-02-11 Time 09:57 Sent To  
Notes
2021-02-11 12:18:442ND REVIEW FBC-2017 RES.
 PERMIT- 20090819
 2/11/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
 2ND REVIEW COMMENTS BASED ON NEW ARCHITECTURAL AND
 PLUMBING PLANS.
  
 1) PLUMBING PLAN: PROVIDE SANITARY DRAINAGE AND VENT
 ISOMETRIC DRAWINGS FOR THE NEW AND REMODELED BATHROOMS,
 BAR, KITCHEN AND LAUNDRY ROOMS- SECTION 107.3.5.3 WPB.
  
 2) P PLAN: PROVIDE A CLEANOUT AT THE JUNCTION OF BATH
 #5 DRAIN AND THE SEWER LINE- SECTION P3005.2.3 FBC RES.
  
 3) P PLAN: PROVIDE AN EQUIPMENT SCHEDULE FOR THE NEW
 WATER HEATER AND SUBMIT MANUFACTURER'S SPECIFICATIONS-
 SECTION G2448.1 FBC RES.
  
 4) THE PLUMBING CONTRACTOR OF RECORD WHO PREPARED THE
 PLUMBING DRAWING SHALL SUBMIT A PLUMBING SUB-PERMIT
 APPLICATION- SECTION 105.1 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-10-22 Cont ID  
Sent By ccole Date 2020-10-22 Time 15:27 Rev Time 0.00
Received By ccole Date 2020-10-22 Time 14:58 Sent To  
Notes
2020-10-22 15:28:111ST REVIEW FBC-2017 RES.
 PERMIT- 20090819
 10/22/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE COMPLETE PLUMBING PLANS AND SPECIFICATIONS
 SECTION 107.3.5.3 WPB AMENDMENTS TO THE FBC-17. PLEASE
 INCLUDE A SCOPE OF WORK OUTLINE ON THE PLANS AND THE
 FOLLOWING LIST OF ITEMS:
  
 A) PLUMBING RISER DRAWING.
  
 B) SHOWER PAN DETAIL.
  
 C) WATER HEATER EQUIPMENT SCHEDULE AND INSTALLATION
 DETAILS (IF APPLICABLE)
  
 D) SLAB REPAIR DETAIL: PROVIDE A ENGINEERED SIGNED AND
 SEALED SLAB REPAIR DETAIL SHOWING THE WIDTH OF THE
 REPAIR; THE MINIMUM THICKNESS AND PSI OF THE CONCRETE
 TO BE REPLACED; THE SIZE, SPACING, AND EMBEDMENT DEPTH
 OF THE DOWELS; AND THE ANCHORING MATERIAL FOR THE
 DOWELS. THE REPAIR SHALL INCLUDE TERMITE TREATMENT OF
 THE SOIL AND THE REQUIRED VAPOR BARRIER OVER
 WELL-COMPACTED SOIL. A COPY OF THE TERMITE CERTIFICATE
 SHALL BE ONSITE FOR FINAL INSPECTION APPROVAL.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2021-02-26 Cont ID  
Sent By medwards Date 2021-02-26 Time 14:32 Rev Time 0.00
Received By medwards Date 2021-02-26 Time 14:31 Sent To  
Notes
2021-02-26 14:32:46ORIGINAL SIGNED AND SEALED PAPER DRAWINGS WERE ROUTED
 TO STORAGE.ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date   Cont ID  
Sent By medwards Date   Time   Rev Time 0.00
Received By medwards Date 2021-02-24 Time 06:25 Sent To  
Notes
2021-02-24 06:28:533RD REQUEST:
  
 ARCHITECT MUST DIGITALLY SIGN AND SEAL THEIR DRAWINGS
 OR YOU MAY BRING THE ORIGINAL SIGNED AND SEALED PAPER
 DRAWINGS TO OUR OFFICE.
  
 PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-02-11 Cont ID  
Sent By medwards Date 2021-02-11 Time 10:37 Rev Time 0.00
Received By medwards Date 2021-02-11 Time 10:37 Sent To  
Notes
2021-02-11 10:39:06ARCHITECT MUST DIGITALLY SIGN AND SEAL THEIR DRAWINGS
 OR YOU MAY BRING THE ORIGINAL SIGNED AND SEALED PAPER
 DRAWINGS TO OUR OFFICE.
  
 PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-10-27 Cont ID  
Sent By medwards Date 2020-10-27 Time 08:46 Rev Time 0.00
Received By medwards Date 2020-10-27 Time 08:46 Sent To  
Notes
2020-10-27 08:47:01PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  