Plan Review Details - Permit 20090754
Plan Review Stops For Permit 20090754
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-12-14 Cont ID  
Sent By cthroop Date 2020-12-14 Time 17:05 Rev Time 0.00
Received By cthroop Date 2020-12-14 Time 16:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-12-01 Cont ID  
Sent By cthroop Date 2020-12-01 Time 11:00 Rev Time 0.00
Received By cthroop Date 2020-12-01 Time 10:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-10-24 Cont ID  
Sent By cthroop Date 2020-10-24 Time 10:12 Rev Time 0.00
Received By cthroop Date 2020-10-24 Time 09:39 Sent To  
Notes
2020-10-24 10:22:45PLAN REVIEW GENERATOR / BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 RE: GENERATOR PAD AND DESIGN WIND LOADS
  
 1) PROVIDE GENERATOR PAD WITH STRUCTURAL DETAILS.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2) STRUCTURAL PAD DETAIL SHALL BE SIGNED BY THE
 DESIGNER.
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT.
 481, F.S. & 61G1.
  
 3) PROVIDE WIND DESIGN PRESSURE REQUIREMENTS.
  
 NOTE: ASSUMED DESIGN CRITERIA FOR THIS SITE: VULT OF
 170MPH, (FIGURE R301.2(4) ) VASD OF 132MPH (TABLE
 R301.2.1.3) RISK CATEGORY I AND EXPOSURE CATEGORY C.
  
 4) PROVIDE WIND DESIGN PRESSURES FOR GENERATOR.
 EVERY STRUCTURE SUBJECT TO WIND LOADS SHALL BE DESIGNED
 PER FBC RES CHPT 3 SECTION R301 OR ASCE 7
  
 R301.2.1 WIND DESIGN CRITERIA.
 BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN
 ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING
 THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED
 FROM FIGURE R301.2(4).
  
 5) LOCATION OF GENERATOR ON SURVEY STATES IT SHALL BE
 LOCATED 5 FEET FROM WINDOWS/DOORS/VENTS. GENERATOR
 SHALL BE LOCATED AT LEAST 10 FEET FROM BUILDING
 OPENINGS.
 R303.5.1 INTAKE OPENINGS.
 MECHANICAL AND GRAVITY OUTDOOR AIR INTAKE OPENINGS
 SHALL BE LOCATED NOT LESS THAN 10 FEET (3048 MM) FROM
 ANY HAZARDOUS OR NOXIOUS CONTAMINANT, SUCH AS VENTS,
 CHIMNEYS, PLUMBING VENTS, STREETS, ALLEYS, PARKING LOTS
 AND LOADING DOCKS.
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-12-01 Cont ID  
Sent By cthroop Date 2020-12-01 Time 11:00 Rev Time 0.00
Received By cthroop Date 2020-12-01 Time 10:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-10-24 Cont ID  
Sent By cthroop Date 2020-10-24 Time 10:09 Rev Time 0.00
Received By cthroop Date 2020-10-24 Time 09:41 Sent To  
Notes
2020-10-24 10:11:36PLAN REVIEW GENERATOR / ELECTRICAL
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC 2014
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
  
 1) PROVIDE UPDATED LOAD CALCULATIONS.
 PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE EXISTING
 AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE IS
 ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2020-11-25 Cont ID  
Sent By ccole Date 2020-11-25 Time 15:28 Rev Time 0.00
Received By ccole Date 2020-10-20 Time 15:12 Sent To  
Notes
2020-10-20 15:28:17THE PREVIOUS REVIEW COMMENTS WERE DELETED. A SEPARATE
 PERMIT APPLICATION #20101378 HAS BEEN SUBMITTED FOR THE
 GAS PIPING INSTALLATION.
 11/25/2020
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-12-14 Cont ID  
Sent By cthroop Date 2020-12-14 Time 17:05 Rev Time 0.00
Received By cthroop Date 2020-12-11 Time 04:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-12-01 Cont ID  
Sent By cthroop Date 2020-12-01 Time 11:01 Rev Time 0.00
Received By cthroop Date 2020-11-26 Time 10:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-11-06 Cont ID  
Sent By lmarchan Date 2020-11-06 Time 09:07 Rev Time 0.00
Received By lmarchan Date 2020-10-09 Time 10:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-10-20 Cont ID  
Sent By ccole Date 2020-10-20 Time 15:30 Rev Time 0.00
Received By ccole Date 2020-10-20 Time 15:12 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-12-14 Cont ID  
Sent By cthroop Date 2020-12-14 Time 17:05 Rev Time 0.00
Received By cthroop Date 2020-12-14 Time 16:46 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-12-01 Cont ID  
Sent By cthroop Date 2020-12-01 Time 10:37 Rev Time 0.00
Received By cthroop Date 2020-12-01 Time 10:59 Sent To  
Notes
2020-12-01 11:00:40PLAN REVIEW / SIGNATURES
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 RE: PRE-CAST PAD ENGINEERING
  
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR
 DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL
 WET SEAL AND SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-10-24 Cont ID  
Sent By cthroop Date 2020-10-24 Time 10:11 Rev Time 0.00
Received By cthroop Date 2020-10-24 Time 09:39 Sent To  
Notes
2020-10-24 10:12:23NEW SIGNATURE REVIEW MAY BE REQUIRED BASED ON THE
 GENERATOR PAD DESIGN SUBMITTED. CT

Review Stop Z ZONING
Rev No 1 Status P Date 2020-11-05 Cont ID  
Sent By kalexand Date 2020-11-05 Time 15:43 Rev Time 0.00
Received By kalexand Date 2020-11-05 Time 15:43 Sent To I
Notes
***NONE***