|
 |
 |
 |
 |
 |
Plan Review Details - Permit 20090729
Plan Review Stops For Permit 20090729 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-11-14 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-11-14 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-11-13 |
Time |
10:22 |
Sent To |
|
|
Notes |
2020-11-14 11:07:52 | | | | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW APPROVED (STRIPING ONLY AS PER | | DESCRIPTION ON PERMIT APPLICATION) |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-11-03 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-11-03 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-11-03 |
Time |
06:06 |
Sent To |
|
|
Notes |
2020-11-03 09:00:44 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | FBC B 107.2.1, THE PLANS ARE NOT CLEAR AS TO THE | | SPECIFIC SCOPE AND AREAS OF WORK UNDER THIS PERMIT. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-11-19 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-11-19 |
Time |
07:34 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-11-12 |
Time |
14:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-11-05 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-11-05 |
Time |
16:51 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-10-26 |
Time |
08:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-11-14 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-11-14 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-11-13 |
Time |
10:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-11-03 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-11-03 |
Time |
09:03 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-11-03 |
Time |
06:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2020-11-18 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2020-11-18 |
Time |
15:21 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2020-11-18 |
Time |
15:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-11-05 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2020-11-05 |
Time |
13:31 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2020-11-05 |
Time |
12:00 |
Sent To |
|
|
Notes |
2020-11-05 13:33:53 | FAILED | | | | 1) THE PLANS NEED TO CLEARLY DEFINE THE SCOPE OF WORK. | | | | 2) THE RESUBMITTAL NEEDS TO INCLUDE THE CITY STRIPING | | DETAIL. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | [email protected] |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |