Plan Review Details - Permit 20090696
Plan Review Stops For Permit 20090696
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status N Date 2020-09-28 Cont ID  
Sent By rmcphers Date 2020-09-28 Time 09:21 Rev Time 0.00
Received By rmcphers Date 2020-09-28 Time 09:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2020-09-30 Time   Rev Time 0.00
Received By lmarchan Date 2020-09-29 Time 14:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2020-09-29 Time   Rev Time 0.00
Received By lmarchan Date 2020-09-28 Time 15:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-09-28 Cont ID  
Sent By rmcphers Date 2020-09-28 Time 09:21 Rev Time 0.00
Received By rmcphers Date 2020-09-17 Time 08:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-09-30 Cont ID  
Sent By ccole Date 2020-09-30 Time 07:22 Rev Time 0.00
Received By ccole Date 2020-09-30 Time 07:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-09-29 Cont ID  
Sent By ccole Date 2020-09-29 Time 13:16 Rev Time 0.00
Received By ccole Date 2020-09-29 Time 07:12 Sent To  
Notes
2020-09-29 13:16:372ND REVIEW FBC-2017 RES.
 PERMIT- 20090696
 9/29/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE SELECTED RHEEM RTEX-24 IS UNDERSIZED FOR THE
 REQUIRED HOT WATER GPM FLOW TO THE FIXTURES. THE
 MANUFACTURER'S TEMPERATURE RISE CHART AND INSTALLATION
 MANUAL FOR THE SELECTED RHEEM RTEX-24 SHOWS A MAX 5.0
 GPM FLOW AT A 33-DEGREE F TEMPERATURE RISE FROM THE
 COLD INLET TEMPERATURE TO HOT WATER OUTLET TEMPERATURE.
 PLEASE NOTE THAT RHEEM MANUFACTURER USES A 70 DEGREE
 COLD WATER TEMPERATURE FOR OUR REGION, AND HOT WATER AT
 A TEMPERATURE OF 110 DEGREES F SHALL BE PROVIDED TO THE
 FIXTURES WHERE REQUIRED- SECTION P2801.1 FBC RES. IT
 APPEARS BY THE SPECS THAT THE RTEX-27 CAN SUPPLY MAX
 5.0 GPM AT A 37-DEGREE TEMP. RISE, AND THE RTEX-36 CAN
 SUPPLY MAX 6.0 GPM AT A TEMP. RISE OF 41 DEGREES. BASED
 ON THE MANUFACTURER'S SPECS, IN ORDER TO SUPPLY A
 MINIMUM OF 6.0 GPM HOT WATER FLOW, IT APPEARS THE
 RTEX-36 WOULD BE THE CODE COMPLIANT CHOICE.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-09-18 Cont ID  
Sent By ccole Date 2020-09-18 Time 15:44 Rev Time 0.00
Received By ccole Date 2020-09-18 Time 14:31 Sent To  
Notes
2020-09-18 15:45:051ST REVIEW FBC-2017 RES.
 PERMIT- 20090696
 9/18/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET 1: THE SUBMITTED MANUFACTURER'S SPECIFICATIONS
 FOR THE ECOSMART POINT OF USE TANKLESS WATER INDICATE
 THE LARGER ECO 11 HAS A MAX FLOW RATE OF 3.2 GPM AT 77
 DEGREES F. THIS APPEARS TO BE UNDERSIZED TO SUPPLY THE
 BATH FIXTURES AND THE WASHING MACHINE PER THE EXAMPLE
 CALCS IN THE SUBMITTAL, AND ALSO ACCORDING TO TABLE
 P2903.1 FBC RES. PROVIDE ON THE PLAN THE SELECTED MAKE
 AND MODEL NUMBER OF THE WATER HEATER AND A LIST OF
 PLUMBING FIXTURES TO BE SUPPLIED WITH HOT WATER FROM
 THE NEW TANKLESS WATER HEATER. INCLUDE THE REQUIRED
 TOTAL GPM FLOW, AND PROVIDE ADDITIONAL SPECS FROM THE
 MANUFACTURER INCLUDING A TEMPERATURE RISE GRAPH TO
 VERIFY CORRECT SIZING- SECTIONS P2801.4 AND M2005.1 FBC
 RES. PLEASE NOTE THE ECOSMART MANUFACTURER OFFERS
 LARGER MODELS FOR WHOLE HOUSE INSTALLATIONS.
  
 2) SHEET 1: FOR CLARIFICATION PLEASE INDICATE THE
 SHOWER VALVE TO BE A TUB/SHOWER COMBINATION VALVE
 UNLESS A SEPARATE VALVE IS TO BE INSTALLED FOR THE TUB-
 SECTION P2708.4 FBC RES.
  
 3) THE $2000.00 VALUE ON THE APPLICATION APPEARS TO BE
 LOW FOR THE SCOPE OF WORK. PLEASE PROVIDE A COPY OF THE
 CONTRACT AND/OR COPIES OF ESTIMATES AND INVOICE TO
 VERIFY TOTAL COST. PLEASE NOTE THTE TOTAL COST SHALL
 INCLUDE LABOR, MATERIALS, FIXTURES, EQUIPMENT, DESIGN
 FEES, AND OVERHEAD AND PROFIT- SECTION 109.3 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-09-30 Cont ID  
Sent By ccole Date 2020-09-30 Time 07:22 Rev Time 0.00
Received By ccole Date 2020-09-30 Time 07:22 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-09-29 Cont ID  
Sent By ccole Date 2020-09-29 Time 13:32 Rev Time 0.00
Received By ccole Date 2020-09-29 Time 07:12 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-09-18 Cont ID  
Sent By ccole Date 2020-09-18 Time 15:29 Rev Time 0.00
Received By ccole Date 2020-09-18 Time 15:29 Sent To  
Notes
***NONE***