Plan Review Details - Permit 20090683
Plan Review Stops For Permit 20090683
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2020-10-06 Cont ID  
Sent By jwitmer Date 2020-10-06 Time 10:28 Rev Time 0.00
Received By jwitmer Date 2020-10-06 Time 10:15 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-09-28 Cont ID  
Sent By jwitmer Date 2020-09-28 Time 15:24 Rev Time 0.00
Received By jwitmer Date 2020-09-28 Time 13:31 Sent To  
Notes
2020-09-28 15:20:34COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-11-16 Cont ID  
Sent By jwitmer Date 2020-11-16 Time 14:28 Rev Time 0.00
Received By jwitmer Date 2020-11-16 Time 14:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-09-28 Cont ID  
Sent By jwitmer Date 2020-09-28 Time 15:27 Rev Time 0.00
Received By jwitmer Date 2020-09-28 Time 13:31 Sent To  
Notes
2020-09-28 15:19:24WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20090683
 ADD: 1475 CENTREPARK BLVD. # 140
 CONT: CHANDLIER CONSTRUCTION
 TEL: 561-791-6934
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. SEPT. 28TH/ 2020
 ACTION: DENIED
  
 1) PLEASE NOTE THE LIFE SAFETY PLAN DOES NOT SHOW THE
 EXIT DIRECTIONAL LIGHTS AND OR EXIT LIGHTS ON THE LIFE
 SAFETY PLAN. THE EXIT DIRECTIONAL AND EXIT LIGHTS ARE
 SHOWN ON THE SHEET E2.1. FOR REVIEW PURPOSES SHEET A-2
 WILL BE USED TO IDENTIFY ROOMS AND DOORS IN QUESTION.
  
 1A) THE TRAINING ROOM IS IDENTIFIED WITH 2 NUMBERS
 SHEET A-2 LIST # 122 WHEREAS SHEET E2.1 LIST THE SAME
 TRAINING ROOM AS 119. DISCREPANCY IN THE PLANS.
 107.2.1.2. ADDITIONAL INFORMATION REQUIRED, TYPO.
  
 1B) TRAINING ROOM 122 AKA 119 HAS 3 DOORS THAT COULD BE
 USED AS EITHER EXIT ACCESS OR EXIT DOORS PLEASE
 IDENTIFY WHICH DOORS WILL BE IDENTIFIED AS A MEANS OF
 EGRESS. THE TRAINING ROOM IS APPROX. 1100 SQ. FT./ 20
 (TRAINING) = 56 OCCUPANTS, 2 EXIT DOORS. WHICH WILL BE
 CONSIDERED THE 2 MEANS OF EGRESS. 2017 FBC-B 1007.1.1.
  
 1C) TRAINING ROOM 121 AKA119 VERSES CORRIDOR 116, DOOR
 023 AND EXIT DIRECTIONAL LIGHT IN CORRIDOR 116. AS
 SHOWN NOW ON THE PLAN, OCCUPANTS ARE BEING LED DOWN A
 PORTION OF CORRIDOR 115 TO CORRIDOR 116 AND BEING LED
 OUTDOOR 023. SINCE THE TENANT SPACE TOTAL OCCUPANT LOAD
 IS GREATER THAN 50 IT WOULD APPEAR DOOR 023 SHOULD
 SWING IN THE OPPOSITE DIRECTION, IN THE DIRECTION OF
 EGRESS TRAVEL, 2017 FBC-B 1010.1.2.1.
  
 1D) AT THE OPPOSITE END OF THE CORRIDOR 116 AND 115
 THERE ARE AGAIN THE SAME PROBLEMS,
 1D)(1) DOOR 012 IT WOULD APPEAR SHOULD SWING IN THE
 OPPOSITE DIRECTION. SINCE THE TENANT SPACE TOTAL
 OCCUPANT LOAD IS GREATER THAN 50 IT WOULD APPEAR DOOR
 023 SHOULD SWING IN THE OPPOSITE DIRECTION, IN THE
 DIRECTION OF EGRESS TRAVEL, 2017 FBC-B 1010.1.2.1.
  
 1D)(2) WHEN YOU ARE IN THE CORRIDOR 115 LET?S SAY
 OFFICE 120 YOU WOULD NOT SEE THE EXIT LIGHT IN CORRIDOR
 116 NOR THE MISSING LIGHT AT THE END OF CORRIDOR 115,
 IT WOULD APPEAR ANOTHER EXIT DIRECTIONAL LIGHT IS
 REQUIRED IN CORRIDOR 115 PLUS ONE AT DOOR 012.
  
 1E) THE OCCUPANT LOAD FOR THE DESIGN STUDIO 1374 SQ.
 FT./ 50 (SHOPS OR VOCATIONAL TRAINING 50 NET) = 28
 OCCUPANTS THAT ARE SHOWN ON SHEET E2.1 GOING OUTDOOR
 004 INTO CORRIDOR 104. WHEN YOU STAND CENTERED IN DOOR
 004 YOU DO NOT EVEN SEE THE EXIT LIGHT AT DOOR 001,
 AGAIN IT WOULD APPEAR A EXIT DIRECTIONAL LIGHT SHOULD
 BE PLACED IN CORRIDOR 104 DIRECTING YOU TO THE EXIT
 DOORS 001.
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-10-20 Cont ID  
Sent By jleahy Date 2020-10-20 Time 09:29 Rev Time 0.00
Received By jleahy Date 2020-10-20 Time 09:20 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2020-10-20 Cont ID  
Sent By jleahy Date 2020-10-20 Time 09:30 Rev Time 0.00
Received By jleahy Date 2020-10-20 Time 09:30 Sent To  
Notes
2020-10-20 09:30:56LV APPROVED FOR TELE/ DATA JLEAHY

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-11-16 Cont ID  
Sent By pleduc Date 2020-11-16 Time   Rev Time 0.00
Received By pleduc Date 2020-11-16 Time 16:01 Sent To  
Notes
2020-11-16 16:01:52THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
 1) THE EXISTING FIRE ALARM SYSTEM DEVICES SHALL BE
 MAINTAINED AND REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
  
  
 2) ANY AND ALL WORK ON THE FIRE ALARM SYSTEM OR DEVICES
 SHALL BE DONE UNDER SEPARATE PERMITS AND SHOP DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-09-21 Cont ID  
Sent By pleduc Date 2020-09-21 Time   Rev Time 0.00
Received By pleduc Date 2020-09-21 Time 13:47 Sent To  
Notes
2020-09-21 13:50:59THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
 1) THE EXISTING FIRE ALARM SYSTEM DEVICES SHALL BE
 MAINTAINED AND REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
  
  
 2) ANY AND ALL WORK ON THE FIRE ALARM SYSTEM OR DEVICES
 SHALL BE DONE UNDER SEPARATE PERMITS AND SHOP DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-11-25 Cont ID  
Sent By medwards Date 2020-11-25 Time 08:03 Rev Time 0.00
Received By medwards Date 2020-11-12 Time 13:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-10-20 Cont ID  
Sent By jleahy Date 2020-10-20 Time 09:34 Rev Time 0.00
Received By jleahy Date 2020-09-16 Time 11:14 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-11-25 Cont ID  
Sent By medwards Date 2020-11-25 Time 08:02 Rev Time 0.00
Received By medwards Date 2020-11-25 Time 08:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-10-08 Cont ID  
Sent By medwards Date 2020-10-08 Time 09:20 Rev Time 0.00
Received By medwards Date 2020-10-07 Time 15:13 Sent To  
Notes
2020-10-08 09:20:441ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20090683
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE ENERGY CALCULATIONS FOR THE NEW AHU
 IN THE TRAINING ROOM. FBC EC C403.1
  
 2) PLEASE PROVIDE SCOPE OF TRAINING IN THE TRAINING
 ROOM. IS THIS AN ASSEMBLY AREA? PLEASE LET THE O.A.
 CALCULATIONS REFLECT THE USE OF SPACE. FBC M TABLE
 403.3.1.1
  
 3) SHEET M6.1; IN THE OUTDOOR AIR CALCULATIONS CHART
 THE AHU-1 DOES NOT HAVE A NUMBER IN THE ?PEOPLE OUTDOOR
 AIR RATE CFM/PERSON, WHY WAS THIS LEFT BLANK?
  
 4) PLEASE SHOW CONDENSATION DISPOSAL FOR AHU-1. FBC M
 307.2.1
  
 5) WHY IS THE DRAWING NOT SHOWING A FD IN THE SUPPLY
 DUCT AT THE CORRIDOR WALL NEAR THE BATHROOMS BUT IS
 SHOWING (2) FD?S FOR RETURN AIR IN THE SAME WALL?
  
 6) PLEASE PROVIDE DETAILS FOR THE PRE ENGINEERED STAND
 FOR THE CONDENSING UNIT. FBC 107.2.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2020-10-05 Cont ID  
Sent By tklarge Date 2020-10-05 Time 07:07 Rev Time 0.00
Received By tklarge Date 2020-10-05 Time 06:12 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-11-16 Cont ID  
Sent By jwitmer Date 2020-11-16 Time 14:28 Rev Time 0.00
Received By jwitmer Date 2020-11-16 Time 14:28 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-09-28 Cont ID  
Sent By jwitmer Date 2020-09-28 Time 15:27 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***