Plan Review Stops For Permit 20090652 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2021-01-12 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-01-12 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-01-12 |
Time |
16:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-10-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-10-27 |
Time |
07:51 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-10-27 |
Time |
07:15 |
Sent To |
|
|
Notes |
2020-10-27 08:08:27 | PLAN REVIEW GENERATOR / BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | RE: PRE-CAST GENERATOR PAD ENGINEERING: | | | | 1.GENERATOR PAD ENGINEERING IS BASED ON VULT OF 186MPH | | AND VASD OF 144MPH, RISK CATEGORY III AND EXPOSURE | | CATEGORY D. | | | | PROVIDE GENERATOR PAD DESIGN USING THE EXISTING SITE | | CONDITIONS: | | | | ASSUMED DESIGN CRITERIA FOR THIS SITE: VULT OF 170MPH, | | (FIGURE R301.2(4) ) VASD OF 132MPH (TABLE R301.2.1.3) | | RISK CATEGORY II AND EXPOSURE CATEGORY C. | | | | 2.PROPOSED PRE-CAST PAD DEMENSIONS ARE 33.75 X 49 | | INCHES. | | GENERATOR DEMENSIONS FROM SPEIFICATIONS PROVIDED ARE | | 29.6 X 48.1 INCHES. | | ANCHORS REQUIRE A MINIMUM OF 3 INCH EDGE DISTANCE. | | IT APPEARS THE PROPOSED PAD IS TOO SMALL. | | | | 3.PROVIDE LOCATION OF GENERATOR ON SURVEY. PROVIDE | | DEMENSIONS TO PROPERTY LINES, TO STRUCTURE AND TO | | OPENINGS IN STRUCTURE. | | | | R303.5.1 INTAKE OPENINGS: MECHANICAL AND GRAVITY | | OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED NOT LESS | | THAN 10 FEET (3048 MM) FROM ANY HAZARDOUS OR NOXIOUS | | CONTAMINANT, SUCH AS VENTS, CHIMNEYS, PLUMBING VENTS, | | STREETS, ALLEYS, PARKING LOTS AND LOADING DOCKS. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-10-24 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2020-10-24 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2020-10-24 |
Time |
11:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
P |
Date |
2021-05-04 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-05-04 |
Time |
08:22 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-05-04 |
Time |
06:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
F |
Date |
2021-04-28 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-04-28 |
Time |
07:56 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-04-26 |
Time |
12:25 |
Sent To |
|
|
Notes |
2021-04-28 07:56:37 | 3RD REVIEW FBC-2017 RES. FUEL GAS | | PERMIT- 20090652 | | 4/28/2021 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE RISER SHOWS TWO GAS PIPING OUTLETS AT THE METER | | HOWEVER METERS TYPICALLY HAVE ONE INLET AND ONE OUTLET. | | PLEASE REVISE THE RISER TO SHOW THE TYPE AND SIZE OF | | THE MAIN OUTLET PIPE AND LENGTH OF THE PIPE FROM THE | | METER TOP THE TEE WHERE THE PE RISER IS CONNECTING. | | PLEASE NOTE THAT THE PIPE MUST BE SIZED LARGE ENOUGH TO | | SUPPLY THE INCREASED GAS LOAD OF 875,000 BTUS AT A | | TOTAL DEVELOPED LENGTH OF 110 FT- SECTION G2413.4.1 FBC | | RES. | | | | A) PLEASE SHOW THE DELIVERY PRESSURE AT THE METER AND | | PRESSURE DROP FOR THE SYSTEM- G2413.2 & G2413.5. | | | | B) LIST ALL PIPE SIZING TABLES ON THE RISER DRAWING- | | G2413.4. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2021-01-14 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-01-14 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-01-14 |
Time |
14:16 |
Sent To |
|
|
Notes |
2021-01-14 16:00:46 | 2ND REVIEW FBC-2017 RES. FUEL GAS | | PERMIT- 20090652 | | 1/14/2020 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) GAS RISER: BASED ON THE SUBMITTED PE PIPE SIZING | | TABLE 402.4(21) FBC FG, THE 1-1/4 IN.PE PIPE IS | | UNDERSIZED TO SUPPLY THE NEW TOTAL LOAD OF 875,000 BTU | | LOAD AT 110 FT. DEVELOPED LENGTH AS INDICATED ON THE | | RISER. PLEASE NOTE THE 110 FT. LENGTH DOES NOT APPEAR | | TO MATCH THE MEASURMENTS ON THE RISER WHICH APPEAR TO | | INDICATE 80 FT. TOTAL LENGTH.THE 1-1/4 IS ALSO | | UNDERSIZED TO PROVIDE THE EXISTING LOAD OF 615 BTU | | BASED ON THE TABLE. | | | | 2) GAS RISER: THE NEW 1 IN. PIPE IS LARGE ENOUGH TO | | SUPPLY THE 260,000 BTU GENERATOR LOAD IF THE NEW PIPE | | IS DIRECTLY CONNECTED TO THE METER AND NOT TEEING OFF | | FROM THE EXISTING 1-1/4 IN. PIPE. PLEASE PROVIDE A | | DETAIL SHOWING THE PIPING CONNECTIONS AT THE METER. | | COMMENTS 3 & 4 BELOW PERTAIN TO THE EXISTING PIPING | | WHICH APPEARS TO NOT BE SIZED PROPERLY. | | | | 3) GAS RISER: PLEASE PROVIDE THE LENGTH OF THE PE PIPE | | RUN FROM THE METER TO THE CSST TEE- SECTION G2413.4.1 | | FBC RES. | | | | 4) GAS RISER: BASED ON THE SUBMITTED CSST PIPE SIZING | | TABLE 402.4(15) THE 1 IN. (31 EHD) IS UNDERSIZED TO | | SUPPLY THE INTERIOR 270,000 BTU LOAD AT 110 FT. | | DEVELOPED LENGTH. ACCORDING TO THE TABLE, AN EHD 46 | | PIPE IS REQUIRED. | | | | 5) THE SUBMITTED SURVEY IS APPEARS TO BE A PHOTO IMAGE | | WITH PRINT TOO SMALL TO READ AND PRINT WHEN ENLARGED | | FOR REVIEW BECOMES BLURRY AND ILLEGIBLE. PLEASE PROVIDE | | THE SURVEY IN A FORMAT THAT CAN BE REVIEWED FOR | | COMPLIANCE- SECTION 107.2.1 WPB. PLEASE MARK THE SURVEY | | TO SHOW GENERATOR'S LOCATION AND CLEARANCE DISTANCES TO | | THE BUILDING, ADJACENT PROPERTY LINES, AND AIR INTAKES | | AND OPERABLE OPENINGS INTO THE BUILDING- SEE SEC. 4.1.4 | | NFPA 37, AND SEC. R303.5.1 FBC RES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-10-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-10-21 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-10-21 |
Time |
09:20 |
Sent To |
|
|
Notes |
2020-10-21 11:42:57 | 1ST REVIEW FBC-2017 RES. FUEL GAS | | PERMIT- 20090652 | | 10/21/2020 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) GAS RISER DRAWING: PLEASE PROVIDE A COMPLETE RISER | | DRAWING THAT INCLUDES THE INTERIOR GAS APPLIANCES | | INSTALLED UNDER PERMIT 98003449 INCLUDING THE WATER | | HEATER, DRYER, AND COOKTOP- SECTIONS G2412.3 & G2412.4 | | FBC RES. | | | | A) SHOW THE CORRECT TOTAL LOAD AND THE INDIVIDUAL LOADS | | OF THE SYSTEM- SECTIONS G2412.3, G2412.4, & G2413.2 FBC | | RES. PLEASE NOTE THE GENERATOR SPECS INDICATE A FULL | | LOAD CAPACITY OF 260,000 BTUH FOR NATURAL GAS. | | | | B) PROVIDE THE TOTAL LENGTH DEVELOPED LENGTH OF THE | | PIPING FROM THE METER TO THE MOST REMOTE OUTLET, AND | | THE INDIVIDUAL BRANCH LENGTHS- SECTIONS G2413.4.1 AND | | G2413.4.2 FBC RES. | | | | C) INDICATE THE INPUT GAS PRESSURE FOR THE GENERATOR | | PER MANUFACTURER'S SPECIFICATIONS AT THE OUTLET SIDE OF | | THE REGULATOR. PLEASE SUBMIT MARKED UP OR HIGHLIGHTED | | SPECS FOR THE REGULATOR SHOWING THE SELECTED MODEL, THE | | MAX INLET AND OUTLET SIZE AND PRESSURES, SPRING DATA, | | AND ORIFICE SIZE- SECTION G2421. | | D) SHOW THE REQUIRED PIPE UNIONS FOR RIGID PIPING | | WITHIN 1 FT. OF EITHER SIDE OF THE REGULATOR- SECTION | | G2421.2(7). | | | | 2) PROVIDE A MARKED UP OR HIGHLIGHTED COPY OF THE | | PROPERTY SURVEY SHOWING THE GENERATOR'S LOCATION AND | | CLEARANCE DISTANCES TO THE BUILDING, ADJACENT PROPERTY | | LINES, AND AIR INTAKES AND OPERABLE OPENINGS INTO THE | | BUILDING- SEE SEC. 4.1.4 NFPA 37, AND SEC. R303.5.1 FBC | | RES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-05-04 |
Time |
|
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2021-05-03 |
Time |
08:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-04-28 |
Time |
|
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2021-04-19 |
Time |
11:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-02-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-02-08 |
Time |
16:31 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-01-07 |
Time |
11:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-11-06 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-11-06 |
Time |
09:23 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-10-09 |
Time |
14:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
N |
Date |
2021-05-04 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-05-04 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-05-04 |
Time |
06:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
N |
Date |
2021-04-26 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-04-26 |
Time |
12:25 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-04-26 |
Time |
12:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2021-01-14 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-01-14 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-01-14 |
Time |
14:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2020-10-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-10-21 |
Time |
12:31 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-10-21 |
Time |
09:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-01-12 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2021-01-12 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-01-12 |
Time |
16:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-10-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-10-27 |
Time |
07:50 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-10-27 |
Time |
07:15 |
Sent To |
|
|
Notes |
2020-10-27 07:51:15 | PLAN REVIEW / SIGNATURES | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | RE: PRE-CAST GENERATOR PAD | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | SIGNATURE. | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | WET SEAL AND SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2021-02-04 |
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2021-02-04 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
kalexand |
Date |
2021-02-04 |
Time |
14:14 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-11-05 |
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2020-11-05 |
Time |
17:03 |
Rev Time |
0.00 |
Received By |
kalexand |
Date |
2020-11-05 |
Time |
17:03 |
Sent To |
I |
|
Notes |
2020-11-05 17:05:17 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. INDICATE SETBACK DIMENSIONS FROM PROPOSED GENERATOR | | EQUIPMENT TO ALL PROPERTY LINES. PURSUANT TO THE CITY | | OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT | | REGULATIONS (ZLDR), SECTION 94-305(B)(4): MECHANICAL | | EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET INTO A | | REQUIRED SETBACK. | | | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | LIKE TO RESUBMIT ELECTRONICALLY, EMAIL | | [email protected] AND REQUEST TO HAVE YOUR | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG | | IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | ARE FINISHED UPLOADING. | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1442 | | TTY: 800.955.8771 | | E: [email protected] | | | | W: WPB.ORG | | |
|
|