Plan Review Details - Permit 20090564
Plan Review Stops For Permit 20090564 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-10-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-10-16 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-10-16 |
Time |
13:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-10-06 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-10-06 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-10-06 |
Time |
13:37 |
Sent To |
|
|
Notes |
2020-10-13 09:14:35 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC 61G20-3.001 PER | | FLORIDA STATUTE 553.842 (5) THAT HAVE BEEN REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | 2) THE PRODUCT APPROVAL FOR THE GARAGE DOORS HAVE | | MAXIMUM DESIGN PRESSURES OF +38, -44 PSF AND THE DESIGN | | DATA ON THE PLANS STATES THE MAXIMUM DOOR AND WINDOW | | PRESSURES ARE +36.8, -48.6 PSF. THE GARAGE DOOR DOES | | NOT MEET THE NEGATIVE PRESSURE SPECIFIED ON THE PLANS. | | FBC 107 | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2020-10-13 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2020-10-13 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2020-10-13 |
Time |
13:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-10-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-10-16 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-10-16 |
Time |
13:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-10-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-10-13 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-10-01 |
Time |
06:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-10-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-10-16 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-10-16 |
Time |
13:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2020-10-06 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-10-06 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-10-06 |
Time |
13:37 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |