Plan Review Details - Permit 20090529
Plan Review Stops For Permit 20090529
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-10-24 Cont ID  
Sent By cthroop Date 2020-10-24 Time 07:24 Rev Time 0.00
Received By cthroop Date 2020-10-24 Time 07:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-10-08 Cont ID  
Sent By cthroop Date 2020-10-08 Time 13:16 Rev Time 0.00
Received By cthroop Date 2020-10-08 Time 12:29 Sent To  
Notes
2020-10-08 13:17:40PLAN REVIEW GENERATOR / BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 RE: PRE-CAST GENERATOR PAD ENGINEERING:
  
 1. THE WEIGTH OF THE PROPOSED 2020 GENERAC POWER
 SYSTEMS, INC. MODEL G007042-3, G007043-3, 22KW
 GENERATOR IS 445LBS.
  
 THE WEIGTH OF THE PROPOSED GENERAC 007042 & 7043, 22KW
 GENERATOR REFRENCED ON THE PRE-CAST PAD ENGINEERING IS
 466LBS. (SEE GENERATOR TABLE)
  
 NOTE: THE WEIGHT OF THE GENERATOR EFFECTS THE DESIGN
 WIND LOADS OF THE GENERATOR. THE DESIGN WIND LOADS OF
 THE GENERATOR MUST MEET THE REQUIREMENTS OF THE
 SITE-SPECIFIC DESIGN WIND LOADS PROVIDED.
 (SEE WIND DESIGN REQUIREMENTS PER ASCE 7-10)
  
 SUBMIT NEW PRE-CAST PAD ENGINEERING USING THE WEIGHT OF
 THE PROPOSED GENERATOR.
  
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-10-06 Cont ID  
Sent By jleahy Date 2020-10-06 Time 10:32 Rev Time 0.00
Received By jleahy Date 2020-10-06 Time 07:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-10-24 Cont ID  
Sent By cthroop Date 2020-10-24 Time 07:25 Rev Time 0.00
Received By cthroop Date 2020-10-09 Time 16:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-10-08 Cont ID  
Sent By cthroop Date 2020-10-08 Time 13:16 Rev Time 0.00
Received By cthroop Date 2020-09-21 Time 15:52 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-10-14 Cont ID  
Sent By equinone Date 2020-10-14 Time 10:50 Rev Time 0.00
Received By equinone Date 2020-10-14 Time 10:50 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-10-08 Cont ID  
Sent By cthroop Date 2020-10-08 Time 13:16 Rev Time 0.00
Received By cthroop Date 2020-10-08 Time 12:29 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-09-29 Cont ID  
Sent By rthermid Date 2020-09-29 Time   Rev Time  
Received By rthermid Date 2020-09-29 Time   Sent To I
Notes
***NONE***