Plan Review Stops For Permit 20090357 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
N |
Date |
2020-09-25 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-09-25 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-09-25 |
Time |
09:53 |
Sent To |
|
|
Notes |
2020-09-25 09:55:21 | DRAWINGS DO NOT SHOW ANY NEW STRUCTURAL OR BUILDING | | WORK. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2021-02-17 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-02-17 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-02-17 |
Time |
09:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2021-01-27 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-01-27 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-01-27 |
Time |
14:29 |
Sent To |
|
|
Notes |
2021-01-27 14:42:13 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | NOT ALLOWED TO HAVE MORE THAN ONE BRANCH CIRCUIT FEED | | AN OUT BUILDING, NEED TO ADD A PANEL TO THE GUEST HOUSE | | AND DRIVE GROUND RODS PER 250. 66, 225.30, 225.31, | | 225.32 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-09-21 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-09-21 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-09-21 |
Time |
13:48 |
Sent To |
|
|
Notes |
2020-09-21 13:52:36 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | ONLY SMOKE ALARMS ARE SHOWN IS THIS EXTENT OF THE WORK? |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
N |
Date |
2020-09-25 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2020-09-25 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2020-09-25 |
Time |
10:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
P |
Date |
2021-02-17 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-02-17 |
Time |
09:58 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-02-11 |
Time |
14:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2021-01-27 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-01-27 |
Time |
14:46 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-01-22 |
Time |
16:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-09-25 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-09-25 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-09-14 |
Time |
09:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2021-01-25 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-01-25 |
Time |
07:24 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-01-25 |
Time |
07:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-09-16 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-09-16 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-09-16 |
Time |
14:07 |
Sent To |
|
|
Notes |
2020-09-16 14:26:40 | PROVIDE SPECIFICATIONS FOR SECURING THE OUTDOOR | | CONDENSING UNIT. FBC RES M1307.2 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2021-01-27 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-01-27 |
Time |
08:41 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-01-27 |
Time |
08:30 |
Sent To |
|
|
Notes |
2021-01-27 08:42:55 | 01/27/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-09-16 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2020-09-16 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2020-09-16 |
Time |
11:30 |
Sent To |
|
|
Notes |
2020-09-16 11:31:23 | 1ST REVIEW FBC-2017 PLUMBING | | PERMIT-20090357 | | 9/16/2020 | | | | CODES IN EFFECT: | | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1. A SUB PLUMBING PERMIT IS REQUIRED BY A LICENSED | | CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS | | TO THE FBC SEC. 105.1. | | | | 2. A SUB IRRIGATION PERMIT IS REQUIRED BY A LICENSED | | CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS | | TO THE FBC SEC. 105.1. | | | | 3. THE PLUMBING PLAN SHALL BEAR THE TITLE BLOCK AND | | ELECTRONIC SEAL AND SIGNATURE OF THE FL. LICENSED | | ARCHITECT OR ENGINEER WHO PREPARED THE DRAWING- SECTION | | 107.2.1 WPB, FL. STATUTES 471.025 & 481.221, AND | | SECTIONS 61G15-23.005 & 61G1-16.005 FAC. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | ATELYO BELISLE | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | [email protected] | | 561-805-6695 | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2021-02-17 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-02-17 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-02-17 |
Time |
09:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2021-01-27 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-01-27 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-01-27 |
Time |
14:43 |
Sent To |
|
|
Notes |
2021-01-27 14:46:38 | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | IS REQUIRED TO BE SIGNED (AND SEALED FOR DESIGN | | PROFESSIONALS) BY THE PERSON RESPONSIBLE FOR THE | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | CORRECTION. ALTERNATIVELY, A SIGNED OR SIGNED/SEALED | | PAPER SET MAY BE SUPPLIED TO THE BUILDING DEPARTMENT | | WHEN ALL TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-09-16 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-09-16 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-09-16 |
Time |
14:31 |
Sent To |
|
|
Notes |
2020-09-16 14:31:27 | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | IS REQUIRED TO BE SIGNED AND SEALED BY THE PERSON | | RESPONSIBLE FOR THE DESIGN. A DIGITAL PLAN REQUIRES A | | DIGITAL SIGNATURE WITH THE PROPER THIRD PARTY | | VERIFICATION. PROVIDE CORRECTION. ALTERNATIVELY, A | | SIGNED/SEALED PAPER SET MAY BE SUPPLIED TO THE BUILDING | | DEPARTMENT WHEN ALL TRADES ARE APPROVED. WPB FBC 107.1; | | FS 471/481 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|