Plan Review Details - Permit 20090164
Plan Review Stops For Permit 20090164
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-10-07 Cont ID  
Sent By rmcdouga Date 2020-10-07 Time 07:20 Rev Time 0.00
Received By rmcdouga Date 2020-10-07 Time 07:17 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-09-11 Cont ID  
Sent By rmcdouga Date 2020-09-11 Time 11:35 Rev Time 0.00
Received By rmcdouga Date 2020-09-11 Time 09:34 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-09-05 Cont ID  
Sent By jleahy Date 2020-09-05 Time 15:57 Rev Time 0.00
Received By jleahy Date 2020-09-05 Time 15:57 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-09-08 Cont ID  
Sent By pleduc Date 2020-09-08 Time   Rev Time 0.00
Received By pleduc Date 2020-09-04 Time 11:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-10-07 Cont ID  
Sent By rmcdouga Date 2020-10-07 Time 07:24 Rev Time 0.00
Received By rmcdouga Date 2020-09-30 Time 15:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-09-29 Cont ID  
Sent By lcrespo Date 2020-09-29 Time 14:15 Rev Time 0.00
Received By lcrespo Date 2020-09-24 Time 07:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-09-11 Cont ID  
Sent By rmcdouga Date 2020-09-11 Time 11:42 Rev Time 0.00
Received By rmcdouga Date 2020-09-03 Time 09:39 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-09-26 Cont ID  
Sent By medwards Date 2020-09-26 Time 07:41 Rev Time 0.00
Received By medwards Date 2020-09-26 Time 07:41 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-09-07 Cont ID  
Sent By medwards Date 2020-09-07 Time 12:43 Rev Time 0.00
Received By medwards Date 2020-09-07 Time 11:40 Sent To  
Notes
2020-09-07 12:43:261ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20090164
  
 CODES IN EFFECT:
  
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M-6: THE REVISION (7A) FOR RESPONSES IS DATED
 08/07/2020, THE REVISION (8) IS DATED 07/15/2020. THE
 REVISION (7A) NOTE (10) HAS THE HUB DRAIN CLOUDED.
 REVISION (8) NOTE (10) HAS THE HUB DRAIN REMOVED AND IS
 NOW A FLOOR DRAIN, THIS CHANGE HAS NOT BEEN CLOUDED.
 PLEASE INDICATE CORRECT DATES AND CLOUD CHANGES. FBC FS
 107.2.1
  
 2) SHEET M-6: FCU-1 CONDENSATE LINE HAS BEEN RELOCATED
 BUT THERE IS NO CLOUD ON THE DRAWINGS SHOWING THIS IS A
 CHANGE. PLEASE CORRECT AND MARK ALL CHANGES TO THIS
 DRAWING WITH CLOUDS. FBC FS 107.2.1
  
 3) SHEET M-10: THE MUA-1 AND MUA-2 SUPPLY DUCT AND
 KEF-1, CU-1 ALL HAVE BEEN ADJUSTED BUT NO CLOUDS ARE ON
 THE DRAWINGS TO IDENTIFY THE CHANGES. PLEASE MAKE SURE
 TO CLOUD ALL REVISIONS ON ALL SHEETS. FBC FS 107.2.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-09-29 Cont ID  
Sent By lcrespo Date 2020-09-29 Time 14:15 Rev Time 0.00
Received By lcrespo Date 2020-09-29 Time 13:48 Sent To  
Notes
2020-09-29 14:15:559/29/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-09-10 Cont ID  
Sent By tklarge Date 2020-09-10 Time 13:55 Rev Time 0.00
Received By lcrespo Date 2020-09-10 Time 08:06 Sent To  
Notes
2020-09-10 13:56:0609/10/20 1ST PLUMBING REVISION REVIEW**DENIED** WITH
 COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. ON PAGE P-4 AN EXTRA P TRAP WAS ADDED TO S2 AND NOT
 SHOWN ON THE ISOMETRIC DIAGRAM, PLEASE SHOW ON P-13 PER
 THE WPB AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION
 ON CONSTRUCTION DOCUMENTS.
  
 2. ON P-5 ITEM 15 THE NEW 3" WATER LINES TO MAIN HAVE
 BEEN ADDED AND NOT CLOUDED AND OR NOT SHOW ON P-14
 ISOMETRIC, PLEASE SHOW PER THE WPB AMENDMENTS TO THE
 FBC SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 3. ON P-5 ITEM 16, PLEASE PROVIDE DETAIL OF THE TRASH
 SHOOT AND A SUITABLE HAZARD BACKFLOW DEVICE PER TABLE
 608.1 OF THE 2017 PLUMBING CODE AND 608.13.3. PLEASE
 SHOW THE DEVICE ON ISOMETRIC OF P-14 PER THE WPB
 AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 4. ON P-11 DIAGRAM 2, THE LAST FLOOR SINK IS VENTED
 WITH AN AIR ADMITTANCE VALVE WHICH IS NOT IN A SUITABLE
 LOCATION UNLESS ACCES TO IT IS SHOWN OR POSSIBLE.
 PLEASE PLEASE CLARIFY OR RE-VENT TO PB3 AND REMOVE THAT
 SINK FROM DOWNSTREAM OF THE SYSTEM TO THE VENT FLOOR
 SINK PER THE WPB AMENDMENTS TO THE FBC SEC.107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-10-07 Cont ID  
Sent By rmcdouga Date 2020-10-07 Time 07:24 Rev Time 0.00
Received By rmcdouga Date 2020-10-07 Time 07:24 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-09-26 Cont ID  
Sent By medwards Date 2020-09-26 Time 07:49 Rev Time 0.00
Received By medwards Date 2020-09-26 Time 07:46 Sent To  
Notes
2020-09-26 07:50:50THE TRASH CHUTE SHOP DRAWINGS MUST BE DIGITALLY SIGNED
 AND SEAL.
 PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-09-11 Cont ID  
Sent By rmcdouga Date 2020-09-11 Time 11:42 Rev Time 0.00
Received By rmcdouga Date 2020-09-11 Time 11:42 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved