Plan Review Details - Permit 20090060
Plan Review Stops For Permit 20090060
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-11-30 Cont ID  
Sent By jgomez Date 2020-11-30 Time 16:34 Rev Time 0.00
Received By jgomez Date 2020-11-30 Time 16:11 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-10-19 Cont ID  
Sent By rmcdouga Date 2020-10-19 Time 11:36 Rev Time 0.00
Received By rmcdouga Date 2020-10-19 Time 11:23 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-09-23 Cont ID  
Sent By rmcdouga Date 2020-09-23 Time 14:24 Rev Time 0.00
Received By rmcdouga Date 2020-09-23 Time 14:23 Sent To  
Notes
2020-09-23 14:26:44PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SUBMIT SIGNED AND SEALED WIND LOAD CALCULATIONS AND
 MOUNTING DETAILS FOR THE SIGN. FBC107.1 & 3107
  
 2) SPECIFY THE WIND LOAD DESIGN DATA ON THE PLANS. FBC
 1609
  
 3) SPECIFY THE LOCATION/ADDRESS OF THE SIGN ON THE
 PLANS. FBC 107.1

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-11-30 Cont ID  
Sent By jgomez Date 2020-11-30 Time 16:35 Rev Time 0.00
Received By jgomez Date 2020-11-17 Time 16:37 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-11-06 Cont ID  
Sent By lmarchan Date 2020-11-06 Time 09:24 Rev Time 0.00
Received By lmarchan Date 2020-10-09 Time 10:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-09-23 Cont ID  
Sent By rmcdouga Date 2020-09-23 Time 14:24 Rev Time 0.00
Received By rmcdouga Date 2020-09-01 Time 15:49 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-11-30 Cont ID  
Sent By jgomez Date 2020-11-30 Time 16:23 Rev Time 0.00
Received By jgomez Date 2020-11-30 Time 16:23 Sent To  
Notes
2020-11-30 16:25:16EMERGENCY RULE.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-10-19 Cont ID  
Sent By rmcdouga Date 2020-10-19 Time 11:35 Rev Time 0.00
Received By rmcdouga Date 2020-10-19 Time 11:23 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-09-23 Cont ID  
Sent By rmcdouga Date 2020-09-23 Time 14:23 Rev Time 0.00
Received By rmcdouga Date 2020-09-23 Time 14:23 Sent To  
Notes
2020-09-23 14:26:54ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE
 THE ENGINEER'S DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE
 THE OPTION TO SUBMIT THE SIGNED AND SEALED PAPER
 VERSION OF DRAWINGS. AFTER THE ELECTRONIC PLANS HAVE
 BEEN APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER
 DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE
 ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE AND SEAL IS
 REQUIRED TO BE ON THE DRAWINGS. NO PHOTOCOPY OR OTHER
 FACSIMILES OF THE SIGNATURE ARE ACCEPTABLE. FS 471 &
 61G15

Review Stop Z ZONING
Rev No 3 Status P Date 2020-11-30 Cont ID  
Sent By jgomez Date 2020-11-30 Time 16:21 Rev Time 0.00
Received By jgomez Date 2020-11-30 Time 16:21 Sent To  
Notes
2020-11-30 16:23:33APPROVED BY KIZZI ALEXANDRE ON 11/24/2020. SEE SIGN
 DESIGN.PDF V3 IN PROJECTDOX. JG.

Review Stop Z ZONING
Rev No 2 Status F Date 2020-11-05 Cont ID  
Sent By kalexand Date 2020-11-05 Time 17:13 Rev Time 0.00
Received By kalexand Date 2020-11-05 Time 17:12 Sent To I
Notes
2020-11-05 17:17:12ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW:
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. AS THE ALLOWABLE SQUARE FOOTAGE OF THE SIGN IS BASED
 ON THE SQUARE FOOTAGE OF THE BUILDING FACADE, PLEASE
 INDICATE BOTH THE HEIGHT AND WIDTH OF THE FACADE ON
 WHICH THE SIGN IS TO BE MOUNTED.
  
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD
 LIKE TO RESUBMIT ELECTRONICALLY, EMAIL
 [email protected] AND REQUEST TO HAVE YOUR
 PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG
 IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL.
 PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU
 ARE FINISHED UPLOADING.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 KIZZI ALEXANDRE, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1442
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  

Review Stop Z ZONING
Rev No 1 Status P Date 2020-09-16 Cont ID  
Sent By kalexand Date 2020-09-16 Time 13:56 Rev Time 0.00
Received By kalexand Date 2020-09-16 Time 13:56 Sent To I
Notes
***NONE***