Plan Review Details - Permit 20090058
Plan Review Stops For Permit 20090058
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-10-19 Cont ID  
Sent By cthroop Date 2020-10-19 Time 16:42 Rev Time 0.00
Received By cthroop Date 2020-10-19 Time 16:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-10-19 Cont ID  
Sent By cthroop Date 2020-10-19 Time 16:41 Rev Time 0.00
Received By cthroop Date 2020-10-19 Time 16:36 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2020-11-13 Cont ID  
Sent By ccole Date 2020-11-13 Time 14:00 Rev Time 0.00
Received By ccole Date 2020-11-13 Time 13:16 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-10-07 Cont ID  
Sent By ccole Date 2020-10-07 Time 13:42 Rev Time 0.00
Received By ccole Date 2020-10-07 Time 12:57 Sent To  
Notes
2020-10-07 13:42:591ST REVIEW FBC-2017 RES. FUEL GAS
 PERMIT- 200900058
 10/7/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) GAS RISER DRAWING: RECORDS RESEARCH FOR 7791 BLUE
 HERON WAY SHOW A GAS PERMIT #01040720 WAS ISSUED ON
 4/8/2001 FOR GAS LINE INSTALLATION THAT INCLUDED A
 FUTURE BBQ AT 40,000 BTUH. THE TOTAL DEVELOPED LENGTH
 OF SYSTEM SHOWN IS 83 FT. TO THE COOKTOP, AND THE TOTAL
 LOAD OF THE SYSTEM INCLUDING THE BBQ IS 378.000 BTUH.
 PLEASE REVISE THE GAS RISER TO MATCH WITH THE APPROVED
 PLANS ON FILE- SECTIONS G2412.3 & G2412.4 FBC RES.
  
 A) SHOW THE CORRECT TOTAL LOAD AND INDIVIDUAL LOADS OF
 THE SYSTEM- SECTIONS G2412.3, G2412.4, & G2413.2 FBC
 RES.
  
 B) PROVIDE THE TOTAL LENGTH DEVELOPED LENGTH OF THE
 PIPING FROM THE METER TO THE MOST REMOTE OUTLET, AND
 THE INDIVIDUAL BRANCH LENGTHS- SECTIONS G2413.4.1 AND
 G2413.4.2 FBC RES.
  
 C) USING THE SIZING TABLE NOTED ON THE RISER- TABLE
 402.4(3), THE 1 IN. RISERS ARE UNDERSIZED FOR EITHER A
 TOTAL LOAD OF 653,000 BTUH AS SHOWN ON THE DRAWING, OR
 A POTENTIAL LOAD OF 684,000 BTUH IF USING THE LOADS
 APPROVED UNDER PERMIT- 01040720. ACCORDING TO THE TABLE
 A MINIMUM 1-1/4 IN. PIPE IS REQUIRED- SECTION G2413.4.1
 FBC RES OR 402.4.1 FBC FG.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-11-25 Cont ID  
Sent By cthroop Date 2020-11-25 Time 07:57 Rev Time 0.00
Received By cthroop Date 2020-11-12 Time 14:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-11-06 Cont ID  
Sent By lmarchan Date 2020-11-06 Time 08:48 Rev Time 0.00
Received By lmarchan Date 2020-10-02 Time 14:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2020-11-13 Cont ID  
Sent By ccole Date 2020-11-13 Time 14:00 Rev Time 0.00
Received By ccole Date 2020-11-13 Time 13:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-10-07 Cont ID  
Sent By ccole Date 2020-10-07 Time 13:46 Rev Time 0.00
Received By ccole Date 2020-10-07 Time 12:57 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-11-25 Cont ID  
Sent By cthroop Date 2020-11-25 Time 07:56 Rev Time 0.00
Received By cthroop Date 2020-11-25 Time 07:51 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-10-19 Cont ID  
Sent By cthroop Date 2020-10-19 Time 16:42 Rev Time 0.00
Received By cthroop Date 2020-10-19 Time 16:28 Sent To  
Notes
2020-10-19 16:43:19PLAN REVIEW / SIGNATURES
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 RE: PRE-CAST GENERATOR PAD ENGINEERING
  
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR
 DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL
 WET SEAL AND SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  

Review Stop Z ZONING
Rev No 2 Status P Date 2020-11-22 Cont ID  
Sent By kalexand Date 2020-11-20 Time 20:21 Rev Time 0.00
Received By kalexand Date 2020-11-20 Time 20:21 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-11-05 Cont ID  
Sent By kalexand Date 2020-11-05 Time 12:31 Rev Time 0.00
Received By kalexand Date 2020-11-05 Time 12:31 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved