Plan Review Details - Permit 20090025
Plan Review Stops For Permit 20090025 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2020-09-23 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-09-23 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-09-23 |
Time |
11:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-09-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-09-04 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-09-04 |
Time |
11:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2020-11-20 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-11-20 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-11-20 |
Time |
14:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-09-11 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-09-11 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-09-11 |
Time |
12:16 |
Sent To |
|
|
Notes |
2020-09-11 12:36:01 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT-20090025 | | | | CODES IN EFFECT: | | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) CANNOT COMPLETE THE REVIEW, NOT ENOUGH INFORMATION | | GIVEN IN THIS SUBMITTAL. FBC FS 107.2.1 | | | | 2) PLEASE IDENTIFY THE GENERATOR USED AND THE WEIGHT OF | | GENERATOR ON THE GENERATOR PAD SPECS PROVIDED. FBC FS | | 107.2.1 | | | | 3) PLEASE PROVIDE METHOD USED TO SIZE THIS NATURAL GAS | | PIPING SYSTEM, I.E.; LONGEST LENGTH OR BRANCH LENGTH | | METHOD? FBC FS 107.2.1 | | | | 4) PLEASE PROVIDE THE DISTANCE TO THE MOST REMOTE | | APPLIANCE FROM THE GAS METER FOR SIZING OF THIS SYSTEM. | | FBC FS 107.2.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-11-20 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-11-20 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-10-14 |
Time |
10:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
P |
Date |
2020-09-23 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-09-23 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-09-01 |
Time |
13:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2020-10-23 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2020-10-23 |
Time |
17:43 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2020-10-23 |
Time |
17:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2020-09-11 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-09-11 |
Time |
12:36 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-09-11 |
Time |
12:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-11-20 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-11-20 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-11-20 |
Time |
14:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-09-11 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-09-11 |
Time |
12:38 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-09-11 |
Time |
12:36 |
Sent To |
|
|
Notes |
2020-09-11 12:38:24 | PLEASE INCLUDE PROPERTY ADDRESS AND CUSTOMER'S NAME ON | | ALL DRAWINGS. FBC FS 107.2.1 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2020-09-08 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-09-08 |
Time |
|
Rev Time |
|
Received By |
rthermid |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy