Plan Review Stops For Permit 20081429 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2020-09-14 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-09-14 |
Time |
12:47 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-09-14 |
Time |
12:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-11-10 |
|
|
Cont ID |
|
Sent By |
mcphers |
Date |
2020-11-10 |
Time |
12:19 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-11-10 |
Time |
12:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-10-21 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-10-21 |
Time |
13:03 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-10-21 |
Time |
13:03 |
Sent To |
|
|
Notes |
2020-10-21 13:11:18 | NEW SFR | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) ONE BATHROOM NEEDS TO HAVE A 29" DOOR OPENING | | CLEARANCE AT TOILET ROOM. FBC R320.1.1 - PLEASE SHOW | | HOW THE 2'6" DOOR WILL ALLOW A CLEAR WIDTH OF 29" - FBC | | ACCESSIBILITY 404.2.3 CLEAR OPENINGS OF DOORWAYS WITH | | SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF | | THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-09-28 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-09-28 |
Time |
12:02 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-09-28 |
Time |
10:18 |
Sent To |
|
|
Notes |
2020-09-28 12:10:29 | NEW SFR | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) ONE BATHROOM NEEDS TO HAVE A 29" DOOR OPENING | | CLEARANCE AT TOILET ROOM. FBC R320.1.1 | | 2) PLEASE PROVIDE A SIGNED AND SEALED SOIL REPORT PER | | NOTES ON THE DRAWINGS. | | 3) PLEASE PROVIDE THE FRONT PAGES FOR THE FL20468 | | FLORIDA STATE PRODUCT APPROVAL. | | 4) PLEASE PROVIDE A COMPLETE MIAMI DADE OR FLORIDA | | STATE PRODUCT APPROVAL FOR THE GARAGE OVERHEAD DOOR | | (FRONT PAGES AND THE INSTALLATION INSTRUCTIONS). | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2020-12-02 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2020-12-02 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2020-12-02 |
Time |
11:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2020-11-12 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2020-11-12 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2020-11-12 |
Time |
09:17 |
Sent To |
|
|
Notes |
2020-11-12 09:27:03 | CODES IN EFFECT | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | REVIEW STATUS: FAILED | | | | 1) NEW ELECTRICAL RISER DIAGRAM SHOWS SEPARATE SERVICE | | DISCONNECT FOR PANEL A. PLEASE SHOW LOCATION OF SERVICE | | DISCONNECT. NEC 230.70 | | 2) PLEASE SPECIFY OVERCURRENT PROTECTION FOR SERVICE | | DISCONNECT TO COMPLY WITH NEC 230.90 AND NEC 230.91 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. | | | | SINCERELY, | | | | ENRIQUE QUINONEZ | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-09-23 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-09-23 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-09-23 |
Time |
14:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-02-01 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-02-01 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-11-17 |
Time |
16:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-11-12 |
|
|
Cont ID |
|
Sent By |
equinone |
Date |
2020-11-12 |
Time |
09:27 |
Rev Time |
0.00 |
Received By |
equinone |
Date |
2020-10-30 |
Time |
00:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-10-21 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-10-21 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-10-13 |
Time |
14:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-09-28 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-09-28 |
Time |
12:13 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-09-11 |
Time |
14:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
P |
Date |
2021-07-22 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-07-22 |
Time |
11:54 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-11-17 |
Time |
16:56 |
Sent To |
|
|
Notes |
2021-07-21 11:51:03 | RECEIPT MU-2020-038094 - $11623.07 PAID | 2020-11-17 16:56:59 | 11/17/20 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2020-11-10 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-11-10 |
Time |
12:20 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-11-10 |
Time |
12:20 |
Sent To |
|
|
Notes |
2020-11-10 12:21:37 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2020-09-28 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-09-28 |
Time |
12:11 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-09-28 |
Time |
12:11 |
Sent To |
|
|
Notes |
2020-09-28 12:12:14 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2020-09-18 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-09-18 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-09-18 |
Time |
14:29 |
Sent To |
|
|
Notes |
2020-09-18 14:29:54 | PROVISO: FBC EC R4.3.3.6 AIR HANDLING UNITS | | AIR HANDLER MAY BE INSTALLED IN THE ATTIC ONLY IF THE | | FOLLOWING CONDITIONS ARE MET. | | 1) THE SERVICE PANEL OF THE EQUIPMENT IS LOCATED WITHIN | | 6 FEET OF AN ATTIC ACCESS. | | 2) A DEVICE IS INSTALLED TO ALERT THE OWNER OR SHUT | | DOWN THE UNIT WHEN THE CONDENSATION DRAIN IS NOT | | WORKING PROPERLY. | | 3) THE ATTIC ACCESS OPENING IS OF SUFFICIENT SIZE TO | | REPLACE THE AIR HANDLER. | | 4) A NOTICE IS POSTED ON THE ELECTRIC SERVICE PANEL | | INDICATING TO THE HOME OWNER THAT THE AIR HANDLER IS | | LOCATED IN THE ATTIC. SAID NOTICE SHALL BE IN ALL | | CAPITALS, IN 16-POINT TYPE WITH THE TITLE AND FIRST | | PARAGRAPH IN BOLD: | | NOTICE TO HOMEOWNER | | | | A PART OF YOUR AIR-CONDITIONING SYSTEM, THE AIR | | HANDLER, IS LOCATED IN THE ATTIC. FOR PROPER, EFFICIENT | | AND ECONOMIC OPERATION OF THE AIR CONDITIONING SYSTEM, | | YOU MUST ENSURE THAT REGULAR MAINTENANCE IS PERFORMED. | | YOUR AIR CONDITIONING SYSTEM IS EQUIPED WITH ONE OR | | BOTH OF THE FOLLOWING: (1) A DEVICE THAT WILL ALERT YOU | | WHEN THE CONDENSATION DRAIN IS NOT WORKING PROPERLY OR | | (2) A DEVICE THAT WILL SHUT DOWN THE SYSTEM WHEN THE | | CONDENSATION DRAIN IS NOT WORKING. TO LIMIT POTENTIAL | | DAMAGE TO YOUR HOME, AND TO AVOID DISRUPTION OF | | SERVICE, IT IS RECOMMENDED THAT YOU ENSURE PROPER | | WORKING ORDER OF THESE DEVICES BEFORE EACH SEASON OF | | PEAK OPERATION. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-09-18 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-09-18 |
Time |
13:41 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-09-18 |
Time |
13:26 |
Sent To |
|
|
Notes |
2020-09-18 13:41:55 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT-20081429 | | | | CODES IN EFFECT: | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE SHOW THAT THE AHU LOCATED IN THE ATTIC MEETS | | SECTION R403.3.6 OF FBC EC | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2020-09-15 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-09-15 |
Time |
16:56 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-09-15 |
Time |
16:56 |
Sent To |
|
|
Notes |
2020-09-15 16:56:56 | 09/15/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2020-09-28 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-09-28 |
Time |
12:12 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-09-28 |
Time |
12:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2021-02-01 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-02-01 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-02-01 |
Time |
16:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2020-11-10 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-11-10 |
Time |
12:21 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-11-10 |
Time |
12:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-10-21 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-10-21 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-10-21 |
Time |
13:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-09-28 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-09-28 |
Time |
12:13 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-09-28 |
Time |
12:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2020-09-21 |
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2020-09-21 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
kalexand |
Date |
2020-09-21 |
Time |
11:05 |
Sent To |
I |
|
Notes |
|
|